The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Maximum-likelihood refinement for coherent diffractive imaging
Open accessAbstract
We introduce the application of maximum-likelihood (ML) principles to the image reconstruction problem in coherent diffractive imaging. We describe an implementation of the optimization procedure for ptychography, using conjugate gradients and including preconditioning strategies, regularization and typical modifications of the statistical noise model. The optimization principle is compared to a difference map reconstruction algorithm. With simulated data important improvements are observed, as measured by a strong increase in the signal-to-noise ratio. Significant gains in resolution and sensitivity are also demonstrated in the ML refinement of a reconstruction from experimental x-ray data. The immediate consequence of our results is the possible reduction of exposure, or dose, by up to an order of magnitude for a reconstruction quality similar to iterative algorithms currently in use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Phase retrieval by iterated projections
Elser, V. (2003) · Journal of the Optical Society of America A · doi:10.1364/josaa.20.000040 · Cited by 737
Probe retrieval in ptychographic coherent diffractive imaging
Thibault, P., Dierolf, M., Bunk, O., Menzel, A., & Pfeiffer, F. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.12.011 · Cited by 717
Self-citationLensless imaging of magnetic nanostructures by X-ray spectro-holography
Eisebitt, S., Lüning, J., Schlotter, W. F., Lörgen, M., Hellwig, O., Eberhardt, W., & Stöhr, J. (2004) · Nature · doi:10.1038/nature03139 · Cited by 684
High-resolution ab initio three-dimensional x-ray diffraction microscopy
Chapman, H. N., Barty, A., Marchesini, S., Noy, A., Hau-Riege, S. P., Cui, C., Howells, M. R., Rosen, R., He, H., Spence, J. C. H., et al. (2006) · Journal of the Optical Society of America A · doi:10.1364/josaa.23.001179 · Cited by 592
Relaxed averaged alternating reflections for diffraction imaging
Luke, D. R. (2005) · Inverse Problems · doi:10.1088/0266-5611/21/1/004 · Cited by 551
Coherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Cited by
Further improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
Holler, M., Diaz, A., Guizar-Sicairos, M., Karvinen, P., Färm, E., Härkönen, E., Ritala, M., Menzel, A., Raabe, J., & Bunk, O. (2014) · Scientific Reports · doi:10.1038/srep03857 · Cited by 357
Self-citationExperimental robustness of Fourier ptychography phase retrieval algorithms
Yeh, L.-H., Dong, J., Zhong, J., Tian, L., Chen, M., Tang, G., Soltanolkotabi, M., & Waller, L. (2015) · Optics Express · doi:10.1364/oe.23.033214 · Cited by 320
Cuesta, A., De la Torre, A. G., Santacruz, I., Trtik, P., da Silva, J. C., Diaz, A., Holler, M., & Aranda, M. A. G. (2017) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.6b10048 · Cited by 55
Critical appraisal of tubular putative eumetazoans from the Ediacaran Weng'an Doushantuo biota
Cunningham, J. A., Vargas, K., Pengju, L., Belivanova, V., Marone, F., Martínez-Pérez, C., Guizar-Sicairos, M., Holler, M., Bengtson, S., & Donoghue, P. C. J. (2015) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2015.1169 · Cited by 26
Self-citation
Metadata
- Authors
- Thibault, P., & Guizar-Sicairos, M.
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2012-06-07
- Volume
- 14
- Issue
- 6
- Pages
- 063004
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W2156713402
- Cited by
- 416
- References
- 15
- FWCI
- 15.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maximum-likelihood refinement for coherent diffractive imaging. https://app.cochat.ai/papers/10.1088/1367-2630/14/6/063004
- The paper
- Thibault, P., & Guizar-Sicairos, M. (2012). Maximum-likelihood refinement for coherent diffractive imaging. New Journal of Physics. https://doi.org/10.1088/1367-2630/14/6/063004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.