New Ventilation Systems at Select Schools in Sweden—Effects on Asthma and Exposure
The DOI matches its Crossref record.
Abstract
The air-exchange rate is often low in schools. The authors studied the possible impact of improving school ventilation on health and exposure of pupils. Questionnaire data on allergies, asthma, and asthmatic symptoms were obtained in 1993 and 1995 for 1,476 primary- and secondary-school pupils in 39 randomly selected schools. Various exposure factors were measured in 1993 and 1995 in approximately 100 classrooms. In 12% of the classrooms, new ventilation systems were installed between 1993 and 1995; the subsequent air-exchange rate increased and the relative humidity and concentration of several airborne pollutants were reduced compared with classrooms in nonimproved buildings. The reporting of at least one asthmatic symptom and the reporting of more asthmatic symptoms in 1995 than in 1993 were less common among the 143 pupils who attended schools with new ventilation systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
“Although limited in scope, reviewed articles revealed poor ventilation conditions to be common in schools and homes, in relation to requirements in guidelines and standards (Bornehag et al., 2005; Smedje and Norbäck, 2000).”
BackgroundAssociations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
“…Green, 1974, 1985; Norback et al., 1990; Ruotsalainen et al., 1995; Myhrvold et al., 1996; Myhrvold and Olsen, 1997; Smedje et al., 1997; Walinder et al., 1997a, 1997b, 1998; Meyer et al., 1999; Ahman et al., 2000; Smedje and Norback, 2000, Kim et al., 2002; Sahlberg et al., 2002; Heschong 2002).”
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Bornehag, C. G., Sundell, J., Bonini, S., Custovic, A., Malmberg, P., Skerfving, S., Sigsgaard, T., & Verhoeff, A. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00240.x · Cited by 313
Metadata
- Authors
- Smedje, G., & Norbäck, D.
- Venue
- Archives of Environmental Health: An International Journal
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 55
- Issue
- 1
- Pages
- 18-25
- ISSN
- 0003-9896 (ISSN-L)
- OpenAlex
- W1981099707
- Cited by
- 139
- References
- 0
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Ventilation Systems at Select Schools in Sweden—Effects on Asthma and Exposure. https://app.cochat.ai/papers/10.1080/00039890009603380
- The paper
- Smedje, G., & Norbäck, D. (2000). New Ventilation Systems at Select Schools in Sweden—Effects on Asthma and Exposure. Archives of Environmental Health: An International Journal. https://doi.org/10.1080/00039890009603380
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.