Measurement of work and power output using friction-loaded cycle ergometers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Friction-loaded cycle ergometers are widely used to measure the work done in short-duration high-intensity exercise. This work is calculated from the product of the average values of flywheel speed and resistive load. This method assumes the flywheel to be revolving at a constant speed and does not take into account the work required to accelerate it. This study examines the possible error resulting from such an assumption. Ten subjects (five males and five females) each performed a single bout of 30 s maximal exercise on a cycle ergometer, from a rolling start, against a resistive loading of 75 g/kg bodyweight. High frequency logging of the flywheel speed was performed by a microcomputer. Two sets of instantaneous and average values of power and work were calculated by the computer at the conclusion of the exercise. The first used the standard method of calculation and did not take into account the acceleration of the flywheel, whereas the second corrected for it. Statistical comparisons of the two sets of results showed: (1) That when no correction is made for flywheel acceleration peak power is greatly underestimated (mean 35·8 ±9·3%). (2) The time taken to reach peak power is shorter when corrected values are used. (3) The instantaneous values of power throughout the 30 s, and the work done calculated for 5 s time intervals, were also different. (4) The total work done during the 30 s was, however, the same irrespective of the method of calculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Balance and kinetics of anaerobic energy release during strenuous exercise in man
Margaria, R., Cerretelli, P., & Mangili, F. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.4.623 · Cited by 150
Cited by
Human muscle metabolism during intermittent maximal exercise
Gaitanos, G. C., Williams, C., Boobis, L. H., & Brooks, S. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.2.712 · Cited by 967
Bogdanis, G. C., Nevill, M. E., Boobis, L. H., & Lakomy, H. K. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.876 · Cited by 691
Self-citationRecovery of power output and muscle metabolites following 30 s of maximal sprint cycling in man
Bogdanis, G. C., Nevill, M. E., Boobis, L. H., Lakomy, H. K., & Nevill, A. M. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp020533 · Cited by 431
Self-citationStandard Anaerobic Exercise Tests
Vandewalle, H., Pérès, G., & Monod, H. (1987) · Sports Medicine · doi:10.2165/00007256-198704040-00004 · Cited by 403
Short-Term Muscle Power During Growth and Maturation
Van Praagh, E., & Dor??, E. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00003 · Cited by 288
Metadata
- Authors
- LAKOMY, H. K. A.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1986-04
- Volume
- 29
- Issue
- 4
- Pages
- 509-517
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2006646089
- Cited by
- 183
- References
- 1
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.