Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man
The DOI matches its Crossref record.
Abstract
Subcutaneous adipose tissue extracellular glucose was investigated in vivo in man with a microdialysis technique. A small dialysis probe (4 or 10 x 0.5 mm) was implanted subcutaneously, and was perfused continuously with a micro-infusion pump. Dialysate samples were collected in 15-min periods. A transient yield of ATP was recorded immediately after insertion of the probe; thereafter ATP was almost undetectable. During steady-state conditions the tissue dialysate glucose concentration remained constant for at least 2 h, which indicated that there was no drainage of glucose from the interstitial fluid to the tissue dialysate. Simultaneous dialysis of venous blood and subcutaneous fat in rats showed that the recovery of glucose from the adipose tissue interstitial fluid to the dialysate was only 20% of that from blood. However, in vivo dialysis of human adipose tissue with glucose-containing solutions produced an equilibrium with the extracellular space at a glucose concentration that was similar to the blood glucose concentration. After oral glucose ingestion and following i.v. insulin and glucose administration the relative variations in subcutaneous glucose closely resembled those in blood glucose. It is concluded that the subcutaneous implantation of the presently used small dialysis device causes only minor and transient traumatic effects. The dialysis recovery of glucose is lower in adipose tissue than in blood. However, the relative kinetics of subcutaneous tissue dialysate glucose are closely related to variations in the blood glucose concentration, and thus may be used for monitoring of glycaemic control in man.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
“various methods including electrochemical detection [101], use of hypodermic needles [102], and microdialysis [103] have been proposed for the assessment of glucose in interstitial spaces as an alternative site rather than the bloodstream.”
MethodAdrenergic regulation of lipolysis in situ at rest and during exercise.
Arner, P., Kriegholm, E., Engfeldt, P., & Bolinder, J. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114516 · Cited by 373
Self-citationThe artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
Assessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue
Regittnig, W., Ellmerer, M., Fauler, G., Sendlhofer, G., Trajanoski, Z., Leis, H.-J., Schaupp, L., Wach, P., & Pieber, T. R. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00351.2002 · Cited by 41
Metadata
- Authors
- Bolinder, J., Hagström, E., Ungerstedt, U., & Arner, P.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1989-01
- Volume
- 49
- Issue
- 5
- Pages
- 465-474
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1968250903
- Cited by
- 130
- References
- 0
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man. https://app.cochat.ai/papers/10.1080/00365518909089123
- The paper
- Bolinder, J., Hagström, E., Ungerstedt, U., & Arner, P. (1989). Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365518909089123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.