Heart Rate Monitors: Validity, Stability, and Functionality
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In brief: The validity of 13 commercially available heart rate (HR) monitors was assessed by comparing the monitored values with simultaneous ECG readings. Stability, as well as validity, was measured using several ergometric devices, and functionality was evaluated by analyzing the practical aspects of each device. Results indicate excellent correlations between readings obtained by ECG and HR monitors using conventional chest electrodes to measure electrical activity of the heart. Most of the monitors using other types of electrodes or using an earlobe photocell to measure opacity of blood flow were inadequate. The authors point out functional differences in the monitors to help potential users choose the best one to fit their needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Heart Rates Measured by ECG and Microcomputer
Karvonen, J., Chwalbinska-Moneta, J., & Saynajakangas, S. (1984) · The Physician and Sportsmedicine · doi:10.1080/00913847.1984.11701872 · Cited by 80
The 'Sport-tester': a device for monitoring the free running test.
Tsanakas, J. N., Bannister, O. M., Boon, A. W., & Milner, R. D. G. (1986) · Archives of Disease in Childhood · doi:10.1136/adc.61.9.912 · Cited by 31
Some factors affecting accuracy of Canadian Home Fitness Test scores.
Shephard, R. J., Cox, M., Corey, P., & Smyth, R. (1979) · PubMed · Cited by 27
Validation du Sport Tester PE 3000 en fonction de l'enregistrement Holter
Vogelaere, P. P., Meyer, F. D., Duquet, W., & Vandevelde, P. (1987) · Science & Sports · doi:10.1016/s0765-1597(87)80024-2 · Cited by 21
Cited by
Heart Rate Monitoring: Applications and Limitations
Achten, J., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333070-00004 · Cited by 1,166
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Ekkekakis, P., & Lind, E. (2006) · International Journal of Obesity · doi:10.1038/sj.ijo.0803052 · Cited by 503
Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345
Validity and Reliability issues in Objective Monitoring of Physical Activity
Bassett, D. R. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082783 · Cited by 326
Evaluation of heart rate as a method for assessing moderate intensity physical activity
STRATH, S. J., SWARTZ, A. M., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00005 · Cited by 301
Tracking of physical activity in young children
PATE, R. R., BARANOWSKI, T., DOWDA, M., & TROST, S. G. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199601000-00019 · Cited by 293
Ekkekakis, P., Hall, E. E., & Petruzzello, S. J. (2004) · Preventive Medicine · doi:10.1016/j.ypmed.2003.09.038 · Cited by 228
“99 range and deviations from 1 to 12 beats min 1 [54,74,84,92].”
BackgroundPhysical activity assessment: A review of methods
Melanson, E. L., Freedson, P. S., & Blair, S. (1996) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408399609527732 · Cited by 223
Heart rate monitors: State of the art
Laukkanen, R. M. T., & Virtanen, P. K. (1998) · Journal of Sports Sciences · doi:10.1080/026404198366623 · Cited by 218
McGibbon, N. H., Andrade, C., Widener, G., & Cintas, H. L. (1998) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1998.tb12344.x · Cited by 213
Exercise intensity during competition time trials in professional road cycling
PADILLA, S., MUJIKA, I., ORBA??ANOS, J., & ANGULO, F. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200004000-00019 · Cited by 201
Evidence and Possible Mechanisms of Altered Maximum Heart Rate With Endurance Training and Tapering
Zavorsky, G. S. (2000) · Sports Medicine · doi:10.2165/00007256-200029010-00002 · Cited by 192
Effect of Audience on Music Performance Anxiety
LeBlanc, A., Jin, Y. C., Obert, M., & Siivola, C. (1997) · Journal of Research in Music Education · doi:10.2307/3345541 · Cited by 188
Lind, E., Joens-Matre, R. R., & Ekkekakis, P. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2004.07.006 · Cited by 159
“99 range and differences between 1 and 12 beats min 1 [62,80,85,89].”
BackgroundWearable activity trackers–advanced technology or advanced marketing?
Shei, R.-J., Holder, I. G., Oumsang, A. S., Paris, B. A., & Paris, H. L. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04951-1 · Cited by 158
“2018) examined eighteen studies and found high correlations for wearable HRV and classic ECG at rest.”
MethodInfluentialAccuracy of wearable heart rate monitors in cardiac rehabilitation
Etiwy, M., Akhrass, Z., Gillinov, L., Alashi, A., Wang, R., Blackburn, G., Gillinov, S. M., Phelan, D., Gillinov, A. M., Houghtaling, P. L., et al. (2019) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2019.04.08 · Cited by 143
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
“Leger and Thivierge [30] compared the validity of 13 heart rate monitors and found the Polar PE 3000 technology to correlate well with ECG readings (r40.”
BackgroundSimultaneous heart rate-motion sensor technique to estimate energy expenditure
STRATH, S. J., BASSETT, D. R., SWARTZ, A. M., & THOMPSON, D. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00022 · Cited by 134
Integration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126
Yan, B. P., Chan, C. K., Li, C. K., To, O. T., Lai, W. H., Tse, G., Poh, Y. C., & Poh, M.-Z. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7275 · Cited by 50
“According to the literature, HR monitors are considered accurate and regarded as excellent when r ≥ .93 and RMSE<6.8% [28,29].”
Influential
Metadata
- Authors
- Léger, L., & Thivierge, M.
- Venue
- The Physician and Sportsmedicine
- Publisher
- Informa UK Limited
- Published
- 1988-05
- Volume
- 16
- Issue
- 5
- Pages
- 143-151
- ISSN
- 0091-3847 (ISSN-L)
- 2326-3660
- OpenAlex
- W2285047079
- Cited by
- 210
- References
- 4
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.