Accuracy of wearable heart rate monitors in cardiac rehabilitation
Open accessAbstract
Background: To assess the accuracy of four wearable heart rate (HR) monitors in patients with established cardiovascular disease enrolled in phase II or III cardiac rehabilitation (CR). Methods: Eighty adult patients enrolled in phase II or III CR were monitored during a CR session that included exercise on a treadmill and/or stationary cycle. Participants underwent HR monitoring with standard ECG limb leads, an electrocardiographic (ECG) chest strap monitor (Polar H7), and two randomly assigned wrist-worn HR monitors (Apple Watch, Fitbit Blaze, Garmin Forerunner 235, TomTom Spark Cardio), one on each wrist. HR was recorded at rest and at 3, 5, and 7 minutes of steady-state exercise on the treadmill and stationary cycle. Results: Across all exercise conditions, the chest strap monitor (Polar H7) had the best agreement with ECG (r c =0.99) followed by the Apple Watch (r c =0.80), Fitbit Blaze (r c =0.78), TomTom Spark (r c =0.76) and Garmin Forerunner (r c =0.52). There was variability in accuracy under different exercise conditions. On the treadmill, only the Fitbit Blaze performed well (r c =0.76), while on the stationary cycle, Apple Watch (r c =0.89) and TomTom Spark (r c =0.85) were most accurate. Conclusions: In cardiac patients, the accuracy of wearable, optically based HR monitors varies, and none of those tested was as accurate as an electrode-containing chest monitor. This observation has implications for in-home CR, as electrode-containing chest monitors should be used when accurate HR measurement is imperative.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In patients with established heart disease undergoing phase II or phase III cardiac rehabilitation, the chest strap had the best concordance with standard ECG during all activities (Lin's concordance coefficient rc = 0.99).
“The chest strap had the best concordance with the standard ECG during all activities (Lin’s concordance coefficient rc = 0.99);”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [23]
In patients with established heart disease undergoing phase II or phase III cardiac rehabilitation, the accuracy of wrist-worn devices varied substantially by the type of activity and 5% of heart rate measurements were substantially inaccurate.
“the accuracy of wrist-worn devices varied substantially by the type of activity and 5% of HR measurements were substantially inaccurate23.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [23]
Four of the ten included studies found no difference in heart rate accuracy between participants of different skin tones.
“Four studies noted no effect of user skin tone on accuracy.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [9]
Etiwy et al. found the Apple Watch to follow ECG data with a correlation coefficient of 0.80, compared to 0.52 in Garmin devices.
“For instance, Etiwy et al. found the Apple Watch to follow ECG data with a correlation coefficient of 0.80, compared to 0.52 in Garmin devices [9].”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [9]
All five studies that compared manufacturers found the Apple Watch to be more accurate than the other commercial devices.
“Of those, all five found the Apple Watch to be more accurate than the other commercial devices [2, 9–12].”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [9]
Etiwy et al. and Sanudo et al. found that skin color did not influence heart rate accuracy.
“Etiwy et al. and Sanudo et al. similarly found that skin color did not influence heart rate accuracy [1, 9].”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536 · see citing works
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · see citing works
European Guidelines on cardiovascular disease prevention in clinical practice (version 2012)
Authors/Task Force Members:, Perk, J., De Backer, G., Gohlke, H., Graham, I., Reiner, Ž., Verschuren, M., Albus, C., Benlian, P., Boysen, G., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs092 · Cited by 8,490 · see citing works
2016 European Guidelines on cardiovascular disease prevention in clinical practice
Piepoli, M. F., Hoes, A. W., Agewall, S., Albus, C., Brotons, C., Catapano, A. L., Cooney, M.-T., Corrà, U., Cosyns, B., Deaton, C., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw106 · Cited by 6,457 · see citing works
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220 · see citing works
O'Connor (2009) · doi:10.1001/jama.2009.454 · Cited by 2,173 · see citing works
Amsterdam, E. A., WENGER, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H. M., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000133 · Cited by 1,258 · see citing works
Smith, S. C., Benjamin, E. J., Bonow, R. O., Braun, L. T., Creager, M. A., Franklin, B. A., Gibbons, R. J., Grundy, S. M., Hiratzka, L. F., Jones, D. W., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.824 · Cited by 903 · see citing works
Amsterdam, E. A., WENGER, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H. M., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.016 · Cited by 780 · see citing works
Lawler, P. R., Filion, K. B., & Eisenberg, M. J. (2011) · American Heart Journal · doi:10.1016/j.ahj.2011.07.017 · Cited by 701 · see citing works
Varnfield, M., Karunanithi, M., Lee, C.-K., Honeyman, E., Arnold, D., Ding, H., Smith, C., & Walters, D. L. (2014) · Heart · doi:10.1136/heartjnl-2014-305783 · Cited by 528 · see citing works
Ades, P. A., Keteyian, S. J., Wright, J. S., Hamm, L. F., Lui, K., Newlin, K., Shepard, D. S., & Thomas, R. J. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.10.014 · Cited by 450 · see citing works
Participation and adherence to cardiac rehabilitation programs. A systematic review
Ruano-Ravina, A., Pena-Gil, C., Abu-Assi, E., Raposeiras, S., van 't Hof, A., Meindersma, E., Bossano Prescott, E. I., & González-Juanatey, J. R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.08.120 · Cited by 413 · see citing works
Kakria, P., Tripathi, N. K., & Kitipawang, P. (2015) · International Journal of Telemedicine and Applications · doi:10.1155/2015/373474 · Cited by 410 · see citing works
Piepoli, M. F., Hoes, A. W., Agewall, S., Albus, C., Brotons, C., Catapano, A. L., Cooney, M.-T., Corrà, U., Cosyns, B., Deaton, C., et al. (2016) · Open Access CRIS of the University of Bern · doi:10.7892/boris.89711 · Cited by 408 · see citing works
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Self-citationVariable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345 · see citing works
Self-citationAlternative models of cardiac rehabilitation: A systematic review
Clark, R. A., Conway, A., Poulsen, V., Keech, W., Tirimacco, R., & Tideman, P. (2013) · European Journal of Preventive Cardiology · doi:10.1177/2047487313501093 · Cited by 300 · see citing works
El-Amrawy, F., & Nounou, M. I. (2015) · Healthcare Informatics Research · doi:10.4258/hir.2015.21.4.315 · Cited by 287 · see citing works
Participation in Cardiac Rehabilitation, Readmissions, and Death After Acute Myocardial Infarction
Dunlay, S. M., Pack, Q. R., Thomas, R. J., Killian, J. M., & Roger, V. L. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2014.02.008 · Cited by 262 · see citing works
Heart Rate Monitors: Validity, Stability, and Functionality
Léger, L., & Thivierge, M. (1988) · The Physician and Sportsmedicine · doi:10.1080/00913847.1988.11709511 · Cited by 210 · see citing works
Current State of Commercial Wearable Technology in Physical Activity Monitoring 2015-2017
Bunn, J., Navalta, J. W., Fountaine, C. J., & Reece, J. (2018) · International Journal of Exercise Science · doi:10.70252/njqx2719 · Cited by 194 · see citing works
Shephard, R. J. (2010) · Yearbook of Sports Medicine · doi:10.1016/s0162-0908(09)79486-3 · Cited by 172 · see citing works
Impact of cardiac rehabilitation and exercise training programs in coronary heart disease
Kachur, S. M., Chongthammakun, V., Lavie, C. J., Schutter, A. D., Arena, R. A., Milani, R. V., & Franklin, B. A. (2017) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2017.07.002 · Cited by 149 · see citing works
Feasibility of home-based cardiac telerehabilitation: Results of TeleInterMed study
Piotrowicz, E., Korzeniowska‐Kubacka, I., Chrapowicka, A., Wolszakiewicz, J., Dobraszkiewicz-Wasilewska, B., Batogowski, M., Piotrowski, W., & Piotrowicz, R. (2014) · Cardiology Journal · doi:10.5603/cj.a2014.0005 · Cited by 64 · see citing works
Brouwers, R. W. M., Kraal, J. J., Traa, S., Spee, R. F., Oostveen, L. M. L. C., & Kemps, H. (2017) · BMC Cardiovascular Disorders · doi:10.1186/s12872-017-0477-6 · Cited by 59 · see citing works
Alzahrani, A., Hu, S., Azorin-Peris, V., Barrett, L. A., Esliger, D., Hayes, M., Akbare, S., Achart, J., & Kuoch, S. (2015) · Sensors · doi:10.3390/s151025681 · Cited by 56 · see citing works
Kraal, J. J., Vromen, T., Spee, R. F., Kemps, H., & Peek, N. B. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.07.051 · Cited by 47 · see citing works
Real-Time Monitoring in Home-Based Cardiac Rehabilitation Using Wrist-Worn Heart Rate Devices
Medina-Quero, J., Olmo, M. R. F., Peláez, M. D., & Espinilla, M. (2017) · Sensors · doi:10.3390/s17122892 · Cited by 36 · see citing works
Determining Target Heart Rate for Exercising in a Cardiac Rehabilitation Program
Sebastian, L. A., REEDER, S. J., & Williams, M. A. (2014) · The Journal of Cardiovascular Nursing · doi:10.1097/jcn.0000000000000154 · Cited by 26 · see citing works
Association Between Phase 3 Cardiac Rehabilitation and Clinical Events
Brawner, C. A., Girdano, D. A., Ehrman, J. K., & Keteyian, S. J. (2016) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000201 · Cited by 13 · see citing works
Verrill, D. E., Ashley, R., Witt, K., & Forkner, T. (1996) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-199601000-00002 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829 · see citing works
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160 · see citing works
Koerber, D., Khan, S., Shamsheri, T., Kirubarajan, A., & Mehta, S. (2023) · Journal of Racial and Ethnic Health Disparities · doi:10.1007/s40615-022-01446-9 · Cited by 91 · see citing works
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Validity of heart rate measurements in wrist-based monitors across skin tones during exercise
Hung, S. H., Serwa, K., Rosenthal, G., & Eng, J. J. (2025) · PLOS ONE · doi:10.1371/journal.pone.0318724 · Cited by 21 · see citing works
Kostrna, J., Oparina, E., Palacios, C., Rodriguez, A. J., Pei, J., Ajmal, A., & Ramella-Roman, J. C. (2026) · Sensors · doi:10.3390/s26102922 · Cited by 2 · see citing works
- Authors
- Etiwy, M., Akhrass, Z., Gillinov, L., Alashi, A., Wang, R., Blackburn, G., Gillinov, S. M., Phelan, D., Gillinov, A. M., Houghtaling, P. L., Javadikasgari, H., & Desai, M. Y.
- Affiliations
- Cleveland Clinic (US)
- Corresponding author
- Desai, Milind Y.
- ORCID
- Venue
- Cardiovascular Diagnosis and Therapy
- Publisher
- AME Publishing Company
- Published
- 2019-06
- Volume
- 9
- Issue
- 3
- Pages
- 262-271
- ISSN
- 2223-3652 (ISSN-L)
- 2223-3660
- PMC
- PMC6603497
- OpenAlex
- W2944738013
- Cited by
- 143
- References
- 33
- Citations by year
- 2026: 14 · 2025: 26 · 2024: 20 · 2023: 21 · 2022: 27 · 2021: 18 · 2020: 13 · 2019: 4
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Update notices
- erratum (2020-06-29)
- Open access
- diamond
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Cardiovascular Diagnosis and Therapy (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Cleveland Clinic
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- wearable heart rate monitor, cardiac rehabilitation, heart rate accuracy, wrist-worn devices, Apple Watch, Fitbit, treadmill exercise, stationary cycling, cardiovascular disease
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review