Evaluation of magnetic nanoparticles for magnetic fluid hyperthermia
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Background: Magnetic nanoparticles (MNPs) generate heat when exposed to an alternating magnetic field. Consequently, MNPs are used for magnetic fluid hyperthermia (MFH) for cancer treatment, and have been shown to increase the efficacy of chemotherapy and/or radiation treatment in clinical trials. A downfall of current MFH treatment is the inability to deliver sufficient heat to the tumor due to: insufficient amounts of MNPs, unequal distribution of MNPs throughout the tumor, or heat loss to the surrounding environment.Objective: In this study, the objective was to identify MNPs with high heating efficiencies quantified by their specific absorption rate (SAR).Methods: A panel of 31 commercially available MNPs were evaluated for SAR in two different AMFs. Additionally, particle properties including iron content, hydrodynamic diameter, core diameter, magnetic diameter, magnetically dead layer thickness, and saturation mass magnetization were investigated.Results: High SAR MNPs were identified. For SAR calculations, the initial slope, corrected slope, and Box–Lucas methods were used and validated using a graphical residual analysis, and the Box–Lucas method was shown to be the most accurate. Other particle properties were identified and examined for correlations with SAR values. Positive correlations of particle properties with SAR were found, including a strong correlation for the magnetically dead layer thickness.Conclusions: This work identified high SAR MNPs for hyperthermia, and provides insight into properties which correlate with SAR which will be valuable for synthesis of next-generation MNPs. SAR calculation methods must be standardized, and this work provides an in-depth analysis of common calculation methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Self-citationGuidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N., & Kuyatt, C. E. (2018) · doi:10.6028/nist.tn.1297-1993 · Cited by 2,582 · cited 1×
“The data are presented as an arithmetic mean ± standard uncertainty of the mean (sðYÞ) [51].”
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Jordan, A., Scholz, R., Wust, P., Fähling, H., & Felix, R. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(99)00088-8 · Cited by 1,494
Progress in applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Thanh, N. T. K., Jones, S. K., & Dobson, J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224001 · Cited by 1,455 · cited 1×
“Despite clinical successes [11], pitfalls of current MFH treatment include the inability to deliver sufficient heat to the tumor due to insufficient MNP tumor loading, heterogeneous distribution of MNPs throughout the tumor, and loss of heat to the surrounding tissues [12,13].”
BackgroundSelf-citationMaier-Hauff, K., Ulrich, F., Nestler, D., Niehoff, H., Wust, P., Thiesen, B., Orawa, H., Budach, V., & Jordan, A. (2011) · Journal of Neuro-Oncology · doi:10.1007/s11060-010-0389-0 · Cited by 1,429
Magnetic Nanoparticles: Surface Effects and Properties Related to Biomedicine Applications
Issa, B., Obaidat, I., Albiss, B., & Haik, Y. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141121266 · Cited by 1,245 · cited 1×
“Thus, the thickness of the magnetically dead layer might contribute to the anisotropy of the MNPs, even though other studies have stated that a small magnetically dead layer will result in improvement of magnetic performance of the nanoparticles such as saturation magnetization [46,67].”
BackgroundSelective Inductive Heating of Lymph Nodes
GILCHRIST, R. K., MEDAL, R., SHOREY, W. D., HANSELMAN, R. C., PARROTT, J. C., & TAYLOR, C. B. (1957) · Annals of Surgery · doi:10.1097/00000658-195710000-00007 · Cited by 1,091
Size-Sorted Anionic Iron Oxide Nanomagnets as Colloidal Mediators for Magnetic Hyperthermia
Fortin, J.-P., Wilhelm, C., Servais, J., Ménager, C., Bacri, J.-C., & Gazeau, F. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067457e · Cited by 1,038 · cited 1×
“Among the highest SAR values for synthetic MNPs reported in the literature is 1650W/(g iron oxide) by the ISM at 31 kA/m and 700 kHz [57] and 600W/g (g of material and calculation method not specified) at 11 kA/m and 410 kHz [58], corresponding to ILP values of 3.”
Background
Cited by
Magnetic nanoparticles in biomedical applications: A review
Materón, E. M., Miyazaki, C. M., Carr, O., Joshi, N., Picciani, P. H. S., Dalmaschio, C. J., Davis, F., & Shimizu, F. M. (2021) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2021.100163 · Cited by 456
Heating technology for malignant tumors: a review
Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1779357 · Cited by 422
Cancer therapy with iron oxide nanoparticles: Agents of thermal and immune therapies
Soetaert, F., Korangath, P., Serantes, D., Fiering, S., & Ivkov, R. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.06.025 · Cited by 406
Paswan, S. K., Kumari, S., Kar, M., Singh, A., Pathak, H., Borah, J. P., & Kumar, L. (2021) · Journal of Physics and Chemistry of Solids · doi:10.1016/j.jpcs.2020.109928 · Cited by 377
Kharat, P. B., Somvanshi, S. B., Khirade, P. P., & Jadhav, K. M. (2020) · ACS Omega · doi:10.1021/acsomega.0c03332 · Cited by 212
Szwed, M., & Marczak, A. (2024) · Cancers · doi:10.3390/cancers16061156 · Cited by 161
“When exposed to a magnetic field, the oscillatory vibrations of MNPs are accompanied by a local increase in temperature and the release of cargo, such as anticancer drugs [48,49].”
Background
Metadata
- Authors
- Lanier, O. L., Korotych, O. I., Monsalve, A. G., Wable, D., Savliwala, S., Grooms, N. W. F., Nacea, C., Tuitt, O. R., & Dobson, J.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2019-01-01
- Volume
- 36
- Issue
- 1
- Pages
- 686-700
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2963188424
- Cited by
- 167
- References
- 60
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.