Reliability of Near-Infrared Spectroscopy for Determining Muscle Oxygen Saturation During Exercise
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Near-infrared spectroscopy is currently used to assess changes in the oxygen saturation of the muscle during exercise. The primary purpose of this study was to assess the reliability of near-infrared spectroscopy in determining muscle oxygen saturation (StO2) in the vastus lateralis during cycling and the gastrocnemius during running for exercise intensities at lactate threshold and maximal effort. Test-retest reliability was determined from an intraclass correlation coefficient obtained from a one-way analysis of variance. Reliability of muscle StO2 for the gastrocnemius at lactate threshold was R = .87, and R = .88 at maximal effort. Reliability of muscle StO2 for the vastus lateralis at lactate threshold was R = .94 and R = .99 at maximal effort.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It also has a high level of reliability during repeated incremental running and cycling tests (Austin et al., 2005).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Austin et al., 2005
In the citing paper
“There has been some controversy surrounding the use of NIRS devices during some incremental running or cycling tests, as some studies have shown correlations between ventilatory thresholds and SmO2 breakpoints (Austin et al., 2005; Feldmann et al., 2022), the first ventilatory threshold and SmO2 breakpoint (van der Zwaard et al., 2016), the second ventilatory threshold and SmO2 breakpoint (Fontana”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Austin et al., 2005
In the citing paper
“However, there is some discrepancy since it does state that it is actually valid in an incremental cycle machine test (Crum et al., 2017), and in another incremental race test it is mentioned that it depends on the subject (Austin et al., 2005).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Austin et al., 2005
In the citing paper
“Although reproducibility of ventilatory thresholds [4] and lactate threshold [5] are known to be high, data on reproducibility of NIRS signals [5,20–22] and NIRS derived breakpoints [23] is limited.”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [5]
In the citing paper
“There is consensus that one can obtain ventilatory or lactate thresholds reproducibly from an incremental exercise test [1,4,5] and can use these thresholds for training purposes [1].”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [5]
Citations
Cites
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 3×
“Mancini et al. (1994) demonstrated that NIRS is a valid tool for determining muscle oxygen use.”
MethodInfluentialMuscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Lactate Kinetics and Individual Anaerobic Threshold*
Stegmann, H., Kindermann, W., & Schnabel, A. (1981) · International Journal of Sports Medicine · doi:10.1055/s-2008-1034604 · Cited by 499
Energy expenditure from minute-by-minute heart-rate recording: comparison with indirect calorimetry
Spurr, G., Prentice, A., Murgatroyd, P., Goldberg, G., Reina, J., & Christman, N. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.3.552 · Cited by 414
The Anaerobic Threshold Measurement to Evaluate Exercise Performance 1, 2
Wasserman, K. (1984) · American Review of Respiratory Disease · doi:10.1164/arrd.1984.129.2p2.s35 · Cited by 413
Physiological Assessment of Human Fitness
LeMura, L. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199607000-00027 · Cited by 395
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy
Hamaoka, T., Iwane, H., Shimomitsu, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Kurosawa, Y., & Chance, B. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.3.1410 · Cited by 280
Research works printed but not linked: 3
- 2004, Investigator's brochure
- Miyashita M., 1981, Journal of Sports Medicine and Physical Fitness, 21, 209
- Wasserman K., 1984, American Review of Respiratory Disease, 61, 260
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1330899 · Cited by 206
“…during exercise (r= 0.92) (Mancini et al., 1994), and from the reproducibility of its measurements during repeated incremental running (r = 0.87–0.88) and cycling (r = 0.94–0.99) tests to exhaustion (Austin et al., 2005), there is little published information regarding the reliability of the Moxy.”
BackgroundInfluentialHwang, C.-L., Yu, C.-J., Shih, J.-Y., Yang, P.-C., & Wu, Y.-T. (2012) · Supportive Care in Cancer · doi:10.1007/s00520-012-1452-5 · Cited by 161
“The probe was firmly attached to the skin overlying the lower third of the vastus lateralis muscle (approximately 10–12 cm above the knee joint) of the lower right limb [22], parallel to the major axis of the thigh.”
BackgroundHaemoglobin oxygen saturation as a biomarker: the problem and a solution
Boas, D. A., & Franceschini, M. A. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0250 · Cited by 135
van der Zwaard, S., Jaspers, R. T., Blokland, I. J., Achterberg, C., Visser, J. M., den Uil, A. R., Hofmijster, M. J., Levels, K., Noordhof, D. A., de Haan, A., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162914 · Cited by 95
“99) [5] and following arterial arm or leg occlusion (ICC = 0.”
Background
Metadata
- Authors
- Austin, K. G., Daigle, K. A., Patterson, P., Cowman, J., Chelland, S., & Haymes, E. M.
- Affiliations
- Florida State University (US)
- San Diego State University (US)
- Venue
- Research Quarterly for Exercise and Sport
- Publisher
- Informa UK Limited
- Published
- 2005-12
- Volume
- 76
- Issue
- 4
- Pages
- 440-449
- ISSN
- 0034-5377 (ISSN-L)
- 0270-1367
- 2168-3824
- OpenAlex
- W2067170187
- Semantic Scholar
- f9420ccf241973cc804010bc3b150c7844a0166c
- Cited by
- 58
- References
- 32
- Citations by year
- 2025: 6 · 2024: 4 · 2023: 7 · 2022: 5 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 8 · 2017: 1 · 2016: 5 · 2015: 1 · 2012: 3
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Research Quarterly for Exercise and Sport (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Keywords
- near-infrared spectroscopy, muscle oxygen saturation, test-retest reliability, vastus lateralis, gastrocnemius, cycling, running, lactate threshold, intraclass correlation coefficient
- MeSH terms
- Adult, Analysis of Variance, Bicycling, Female, Heart Rate, Humans, Male, Oxygen, Oxygen Consumption, Physical Endurance, Running, Reproducibility of Results, Exercise, Muscle, Skeletal, Spectroscopy, Near-Infrared, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).