Indoor Sources of Ultrafine and Accumulation Mode Particles: Size Distributions, Size-Resolved Concentrations, and Source Strengths

Open access
Wallace, Lance · 2006 · Aerosol Science and Technology
Cited by 187

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

Ultrafine (< 100 nm) and accumulation mode (0.1–1 μm) particles were monitored in an occupied suburban house at 5-minute intervals for 37 consecutive months between November 21, 1997 and December 31, 2000. Number concentrations for 126 particle sizes from 9.8–947 nm were measured in 259,176 scans. Of 282 separate activities, 18 were chosen for detailed analysis. These included cooking with a gas stove, toasting with electric toasters and toaster ovens, burning candles and incense, and using a gas-powered clothes dryer. Activities leading to increased particle concentrations occurred 17.5% of the time, and accounted for more than half the total concentration of ultrafines and about a quarter of the total accumulation mode particles. The average duration of elevated particle concentrations ranged from 20 minutes to 3 hours. Combustion of natural gas (boiling water, gas clothes dryer) showed number peaks near 10 nm, while the electric toaster and toaster oven had peaks close to 30 nm. More complex cooking (burners plus gas oven) produced peaks in the 35–50 nm range. Burning candles and incense resulted in peaks in the 60-nm range. Finally, outdoor sources peaked at nearly 70 nm, indicating the influence of aging in shifting modes to higher diameters. The highest mean number concentrations were due to complex cooking, producing average number concentrations of 35,000–50,000 cm− 3, compared to 12,000 cm−3 outdoors and less than 3500 cm−3 indoors when no sources were observed. A strong contribution of the vented gas-powered clothes dryer was also noted (30,000 cm− 3). Volume concentrations due to these combustion events ranged from < 1 (μm/cm)3 to nearly 100 (μm/cm)3. Source strengths were calculated for three common cooking types (boiling water, deep-frying, oven baking, and broiling) and ranged from 5 × 10 12 to 4 × 10 13 particles per cooking event. The detailed concentration and size distribution data collected here may be useful for models of indoor air particle concentrations due to indoor sources and infiltration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786820600612250

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 187

Metadata

Authors
Wallace, L.
Venue
Aerosol Science and Technology
Published
2006-06
Volume
40
Issue
5
Pages
348-360
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W2052016434
Cited by
187
References
44
FWCI
3.97
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.