Bias in Filter-Based Aerosol Light Absorption Measurements Due to Organic Aerosol Loading: Evidence from Ambient Measurements
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
During the 2006 Texas Air Quality Study/Gulf of Mexico Atmospheric Composition and Climate Study (TexAQS/GoMACCS 2006) a filter-based (Particle Soot Absorption Photometer, or PSAP) and a photoacoustic-based aerosol light absorption technique were deployed and here the data are compared. The level of agreement between the two techniques with ambient aerosol depended on the abundance of organic aerosol (OA), with the ratio of OA to light absorbing carbon (LAC) mass (R OA−LAC ) of particular importance. When OA mass concentration was low the agreement between the methods was within instrumental uncertainties (PSAP measuring 12% higher), however at high (R OA−LAC ) (∼15–20) the difference in agreement was between 50 and 80%. This difference is similar to the bias observed in the laboratory studies of a companion paper using non-absorbing OA and LAC (Cappa et al. 2008a). It was found that most of the OA was oxidized and non-absorbing in nature. We postulate that the observed differences results from a bias in the filter-based measurements due to (a) the redistribution of liquid-like organic particulate matter (PM) around the fiber filters thereby modifying the filter surface and subsequent light scattering, and (b) the possible coating and absorption enhancement of pre-existing absorbing PM (i.e., soot) as OA deposition and redistribution occurs. We stop short or recommending a universal correction using these findings due to the magnitude of the bias showing some dependence on air mass type. Any use of this data for a correction must consider the uncertainties in measuring OA mass concentrations, LAC mass concentrations and type of OA present. The observed PSAP bias may have a significant impact on the accuracy of aerosol single scatter albedo (SSA) and LAC mass concentrations derived from filter-based aerosol absorption methods from regions impacted by large amounts of OA. Although this study was performed using the PSAP we caution users of other filter-based instrumentation to the possibility of a similar bias in those instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2018) · Geophysical Research Letters · doi:10.1002/(issn)1944-8007 · Cited by 3,049
Light Absorption by Carbonaceous Particles: An Investigative Review
Bond, T. C., & Bergstrom, R. W. (2006) · Aerosol Science and Technology · doi:10.1080/02786820500421521 · Cited by 2,980 · cited 1×
“The mass concentration of LAC for the ambient data, was estimated from the measured babs,PAS using a mass absorption coefficient (MAC) of 7.75 m2g−1 (literature value converted to 532 nm from 550 nm using Åabs = 1, Kirchstetter et al. 2004) from Bond and Bergstrom (2006).”
MethodInfluentialEvidence that the spectral dependence of light absorption by aerosols is affected by organic carbon
Kirchstetter, T. W., Novakov, T., & Hobbs, P. V. (2004) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2004jd004999 · Cited by 1,608 · cited 3×
“Kirchstetter et al. (2004) showed that some compounds in OA emitted by biomass combustion (termed CBROWN due to their brown or yellow appearance) have a spectral dependence of light absorption that is stronger than that due to soot (i.e., Åabs for soot = 1; Åabs for CBROWN > 1).”
BackgroundMethodInfluentialWeingartner, E., Saathoff, H., Schnaiter, M., Streit, N., Bitnar, B., & Baltensperger, U. (2003) · Journal of Aerosol Science · doi:10.1016/s0021-8502(03)00359-8 · Cited by 1,260 · cited 2×
“Slowik et al. (2007) found Rabs was consistently 1.2 for aethelometer and PAS absorption, while Weingartner et al. (2003) found discrepancies in aethelometer results when soot particles were coated with organic aerosol (OA) from ozonolysis of α-pinene.”
BackgroundInfluentialHansen, A. D. A., Rosen, H., & Novakov, T. (1984) · Science of The Total Environment · doi:10.1016/0048-9697(84)90265-1 · Cited by 1,081 · cited 1×
“The filter-based method is integral to the aethelometer (Hansen et al. 1984; Arnott et al. 2005), the particle soot absorption photometer (PSAP) (Bond et al. 1999; Virkkula et al. 2005) and the multi-angle absorption photometer (MAAP) 1033 (Petzold et al. 2005).”
MethodCalibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols
Bond, T. C., Anderson, T. L., & Campbell, D. (1999) · Aerosol Science and Technology · doi:10.1080/027868299304435 · Cited by 1,022 · cited 9×
“We present PSAP data (babs,PSAP) corrected using the firmware corrections for the three wavelength PSAP which includes the filter transmission, flow and basic sample area corrections from Bond et al. (1999).”
BackgroundMethodResultInfluentialDetermining Aerosol Radiative Properties Using the TSI 3563 Integrating Nephelometer
Anderson, T. L., & Ogren, J. A. (1998) · Aerosol Science and Technology · doi:10.1080/02786829808965551 · Cited by 896 · cited 1×
“Aerosol scattering was measured using a TSI1 nephelometer (model 3563, TSI, Inc., St. Paul, MN), corrected for illumination non-idealities according to Anderson and Ogren (1998) and converted to 532nm using the nephelometerderived scattering Ångström exponent.”
MethodHuebert, B. J., Bates, T., Russell, P. B., Shi, G., Kim, Y. J., Kawamura, K., Carmichael, G., & Nakajima, T. (2003) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2003jd003550 · Cited by 809 · cited 1×
“The majority of in-situ data for aerosol absorption measured globally is based on these filter measurements (e.g., Global Atmospheric Watch program, ACE—Asia, Baltensperger 2003; Huebert et al. 2003).”
MethodSelf-citationLimitations in the enhancement of visible light absorption due to mixing state
Bond, T. C., Habib, G., & Bergstrom, R. W. (2006) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2006jd007315 · Cited by 627 · cited 2×
“The LAC mass concentration is likely an upper limit as the MAC used is for fresh soot and can increase by a factor of ∼1.5 as the aerosol ages (Bond et al. 2006).”
BackgroundInfluentialZhang, Q., Alfarra, M. R., Worsnop, D. R., Allan, J. D., Coe, H., Canagaratna, M. R., & Jimenez, J. L. (2005) · Environmental Science & Technology · doi:10.1021/es048568l · Cited by 605 · cited 1×
“Organic aerosol mass concentrations (including oxygenated organic aerosol (OOA) and hydrocarbon-like organic aerosol (HOA)) were determined from an Aerodyne1 quadrupole aerosol mass spectrometer (QAMS) (Allan et al. 2003; Zhang et al. 2005).”
MethodArnott, W. P., Hamasha, K., Moosmüller, H., Sheridan, P. J., & Ogren, J. A. (2005) · Aerosol Science and Technology · doi:10.1080/027868290901972 · Cited by 598 · cited 2×
“Laboratory comparisons of absorption from soot generated within a controlled flame achieve agreement within stated experimental uncertainties (Bond et al. 1999; Arnott et al. 2005; Virkkula et al. 2005).”
BackgroundMethodAllan, J. D., Jimenez, J. L., Williams, P. I., Alfarra, M. R., Bower, K. N., Jayne, J. T., Coe, H., & Worsnop, D. R. (2003) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2002jd002358 · Cited by 564 · cited 1×
“Organic aerosol mass concentrations (including oxygenated organic aerosol (OOA) and hydrocarbon-like organic aerosol (HOA)) were determined from an Aerodyne1 quadrupole aerosol mass spectrometer (QAMS) (Allan et al. 2003; Zhang et al. 2005).”
MethodPhotoacoustic spectrometer for measuring light absorption by aerosol: instrument description
Patrick Arnott, W., Moosmüller, H., Fred Rogers, C., Jin, T., & Bruch, R. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(98)00361-6 · Cited by 385 · cited 1×
“For example Moosmuller et al. (1998) and Arnott et al. (1999) compared photoacoustic- and aethelometermeasured absorption for ambient samples and found Rabs as low as 0.5 (aethelometer and PAS).”
BackgroundInfluentialSchmid, O., Artaxo, P., Arnott, W. P., Chand, D., Gatti, L. V., Frank, G. P., Hoffer, A., Schnaiter, M., & Andreae, M. O. (2006) · Atmospheric Chemistry and Physics · doi:10.5194/acp-6-3443-2006 · Cited by 330
Mixing of the Organic Aerosol Fractions: Liquids as the Thermodynamically Stable Phases
Marcolli, C., Luo, B., & Peter, T. (2004) · The Journal of Physical Chemistry A · doi:10.1021/jp036080l · Cited by 316 · cited 1×
“Recent theoretical and laboratory studies suggest that complex mixtures of organic compounds that exist as particles are predominantly liquid-like (Marcolli et al. 2004; Subramanian et al. 2007; Cappa et al. 2008b).”
BackgroundAbsorption Coefficient of Atmospheric Aerosol: a Method for Measurement
Lin, C.-I., Baker, M., & Charlson, R. J. (1973) · Applied Optics · doi:10.1364/ao.12.001356 · Cited by 312 · cited 1×
“Filter-based techniques for measuring aerosol light absorption, which have been used for decades (Lin et al. 1973), rely on the change in transmission of light through a filter as it is loaded with aerosol to determine the aerosol absorption coefficient (babs).”
BackgroundEvaluation of Multiangle Absorption Photometry for Measuring Aerosol Light Absorption
Petzold, A., Schloesser, H., Sheridan, P. J., Arnott, W. P., Ogren, J. A., & Virkkula, A. (2005) · Aerosol Science and Technology · doi:10.1080/027868290901945 · Cited by 305 · cited 2×
“%) for pure soot, compared to other filter-based techniques (Petzold et al. 2005).”
BackgroundMethodTropospheric ozone climatology over Beijing: analysis of aircraft data from the MOZAIC program
Ding, A. J., Wang, T., Thouret, V., Cammas, J.-P., & Nédélec, P. (2008) · Atmospheric Chemistry and Physics · doi:10.5194/acp-8-1-2008 · Cited by 285
An Inter-Comparison of Instruments Measuring Black Carbon Content of Soot Particles
Slowik, J. G., Cross, E. S., Han, J.-H., Davidovits, P., Onasch, T. B., Jayne, J. T., Williams, L. R., Canagaratna, M. R., Worsnop, D. R., Chakrabarty, R. K., et al. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701197078 · Cited by 277 · cited 1×
“Slowik et al. (2007) found Rabs was consistently 1.2 for aethelometer and PAS absorption, while Weingartner et al. (2003) found discrepancies in aethelometer results when soot particles were coated with organic aerosol (OA) from ozonolysis of α-pinene.”
InfluentialLack, D. A., Lovejoy, E. R., Baynard, T., Pettersson, A., & Ravishankara, A. R. (2006) · Aerosol Science and Technology · doi:10.1080/02786820600803917 · Cited by 275
Self-citationVirkkula, A., Ahlquist, N. C., Covert, D. S., Arnott, W. P., Sheridan, P. J., Quinn, P. K., & Coffman, D. J. (2005) · Aerosol Science and Technology · doi:10.1080/027868290901963 · Cited by 262 · cited 7×
“An additional filter sample area correction (0.873) according to Sheridan et al. (2005) was applied prior to applying the scattering corrections of Virkkula et al. (2005) (1.3%, 1.6%, and 2.1% for 467 nm, 530 nm, and 660 nm, respectively).”
BackgroundMethodInfluentialSelf-citationThe Reno Aerosol Optics Study: An Evaluation of Aerosol Absorption Measurement Methods
Sheridan, P. J., Arnott, W. P., Ogren, J. A., Andrews, E., Atkinson, D. B., Covert, D. S., Moosmüller, H., Petzold, A., Schmid, B., Strawa, A. W., et al. (2005) · Aerosol Science and Technology · doi:10.1080/027868290901891 · Cited by 237 · cited 1×
“An additional filter sample area correction (0.873) according to Sheridan et al. (2005) was applied prior to applying the scattering corrections of Virkkula et al. (2005) (1.3%, 1.6%, and 2.1% for 467 nm, 530 nm, and 660 nm, respectively).”
MethodInfluentialSelf-citationCappa, C. D., Lack, D. A., Burkholder, J. B., & Ravishankara, A. R. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802389285 · Cited by 217
Self-citationYellow Beads and Missing Particles: Trouble Ahead for Filter-Based Absorption Measurements
Subramanian, R., Roden, C. A., Boparai, P., & Bond, T. C. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701344589 · Cited by 147 · cited 4×
“This bias is likely due to coating of the filter fibers by OA (Subramanian et al. 2007), thereby changing the filter scattering artifact.”
BackgroundInfluentialMeasurement and Uncertainty of the Long-Term Total Solar Irradiance Trend
Dewitte, S., Crommelynck, D., Mekaoui, S., & Joukoff, A. (2004) · Solar Physics · doi:10.1007/s11207-005-5698-7 · Cited by 137 · cited 4×
“#a F ↑ = 1 2 FT T 2(1 − AC ) × [SS Aβa(1 − Rs)2 − 2(1 − SS A)Rs]AOD [2] We estimate the TOA forcing (#a F ↑) using a solar constant (FT ) of 1366 Wm−2 (Dewitte et al. 2004), atmospheric transmission (T ) of 0.76 (Russell et al. 2002), aerosol optical depth (AOD) and aerosol backscatter fraction…”
MethodInfluentialBaynard, T., Lovejoy, E. R., Pettersson, A., Brown, S. S., Lack, D. A., Osthoff, H. D., Massoli, P., Ciciora, S. J., Dubé, W. P., & Ravishankara, A. R. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701222801 · Cited by 121 · cited 1×
“…and measured light absorption (babs,PAS, in Mm−1) at 532 nm. Aerosol extinction (bext) and gas-phase absorption (bext,gas) at 532 nm were measured using a cavity ring downaerosol extinction spectrometer (CRD-AES) sampling aerosolcontaining and aerosol-free air, respectively (Baynard et al. 2007).”
MethodSelf-citationMoosmüller, H., Arnott, W. P., Rogers, C. F., Chow, J. C., Frazier, C. A., Sherman, L., & Dietrich, D. L. (1998) · Journal of Geophysical Research Atmospheres · doi:10.1029/98jd02618 · Cited by 108 · cited 2×
“It was suggested that the discrepancies could be related to “spatial inhomogeneities in aerosol properties” due to separation of sampling inlets, inaccurate instrument measurements or “temporal changes in the aerosol absorption efficiency” (Moosmuller et al. 1998).”
BackgroundInfluentialPhotothermal Interferometric Aerosol Absorption Spectrometry
Sedlacek, A. J., & Lee, J. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701697812 · Cited by 91 · cited 1×
“Sedlacek and Lee (2007), using a photo-thermal interferometery (PTI) technique to measure aerosol absorption on ambient aerosol, showed good correlations with a PSAP (Rabs = 1.03) for low RH conditions.”
MethodInfluentialSchmid, B., Livingston, J. M., Russell, P. B., Durkee, P. A., Jonsson, H. H., Collins, D. R., Flagan, R. C., Seinfeld, J. H., Gassó, S., Hegg, D. A., et al. (2000) · Tellus B · doi:10.3402/tellusb.v52i2.16659 · Cited by 89
Uncertainty Requirements in Radiative Forcing of Climate Change
Schwartz, S. E. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10471006 · Cited by 80 · cited 1×
“Light absorption is a critical component of aerosol optical properties required to determine the radiative forcing by atmospheric aerosol (Schwartz 2004).”
Background
Cited by
Bounding the role of black carbon in the climate system: A scientific assessment
Bond, T. C., Doherty, S. J., Fahey, D. W., Forster, P. M., Berntsen, T., DeAngelo, B. J., Flanner, M. G., Ghan, S., Kärcher, B., Koch, D., et al. (2013) · Journal of Geophysical Research: Atmospheres · doi:10.1002/jgrd.50171 · Cited by 6,385
“In addition, coating of BC with volatile compounds can greatly contribute to variation in filter-based measurements of light absorption [Lack et al., 2008; Cappa et al., 2008; Kondo et al., 2009].”
BackgroundSelf-citationAerosol light absorption and its measurement: A review
Moosmüller, H., Chakrabarty, R. K., & Arnott, W. P. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.02.035 · Cited by 867
Light absorption by organic carbon from wood combustion
Chen, Y., & Bond, T. C. (2010) · Atmospheric Chemistry and Physics · doi:10.5194/acp-10-1773-2010 · Cited by 823
Lack, D. A., & Cappa, C. D. (2010) · Atmospheric Chemistry and Physics · doi:10.5194/acp-10-4207-2010 · Cited by 583
Self-citationBrown carbon and internal mixing in biomass burning particles
Lack, D. A., Langridge, J. M., Bahreini, R., Cappa, C. D., Middlebrook, A. M., & Schwarz, J. P. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1206575109 · Cited by 533
Self-citation
Metadata
- Authors
- Lack, D. A., Cappa, C. D., Covert, D. S., Baynard, T., Massoli, P., Sierau, B., Bates, T. S., Quinn, P. K., Lovejoy, E. R., & Ravishankara, A. R.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2008-10-23
- Volume
- 42
- Issue
- 12
- Pages
- 1033-1041
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W4255632308
- Cited by
- 235
- References
- 30
- FWCI
- 12.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.