CoChat

Bias in Filter-Based Aerosol Light Absorption Measurements Due to Organic Aerosol Loading: Evidence from Ambient Measurements

Open access
Lack, Daniel A., Cappa, Christopher D., Covert, David S., Baynard, Tahllee, Massoli, Paola, Sierau, Berko, Bates, Timothy S., Quinn, Patricia K., Lovejoy, Edward R., Ravishankara, A. R. · 2008 · Aerosol Science and Technology
Cited by 235

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

During the 2006 Texas Air Quality Study/Gulf of Mexico Atmospheric Composition and Climate Study (TexAQS/GoMACCS 2006) a filter-based (Particle Soot Absorption Photometer, or PSAP) and a photoacoustic-based aerosol light absorption technique were deployed and here the data are compared. The level of agreement between the two techniques with ambient aerosol depended on the abundance of organic aerosol (OA), with the ratio of OA to light absorbing carbon (LAC) mass (R OA−LAC ) of particular importance. When OA mass concentration was low the agreement between the methods was within instrumental uncertainties (PSAP measuring 12% higher), however at high (R OA−LAC ) (∼15–20) the difference in agreement was between 50 and 80%. This difference is similar to the bias observed in the laboratory studies of a companion paper using non-absorbing OA and LAC (Cappa et al. 2008a). It was found that most of the OA was oxidized and non-absorbing in nature. We postulate that the observed differences results from a bias in the filter-based measurements due to (a) the redistribution of liquid-like organic particulate matter (PM) around the fiber filters thereby modifying the filter surface and subsequent light scattering, and (b) the possible coating and absorption enhancement of pre-existing absorbing PM (i.e., soot) as OA deposition and redistribution occurs. We stop short or recommending a universal correction using these findings due to the magnitude of the bias showing some dependence on air mass type. Any use of this data for a correction must consider the uncertainties in measuring OA mass concentrations, LAC mass concentrations and type of OA present. The observed PSAP bias may have a significant impact on the accuracy of aerosol single scatter albedo (SSA) and LAC mass concentrations derived from filter-based aerosol absorption methods from regions impacted by large amounts of OA. Although this study was performed using the PSAP we caution users of other filter-based instrumentation to the possibility of a similar bias in those instruments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/02786820802389277

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 235

Metadata

Authors
Lack, D. A., Cappa, C. D., Covert, D. S., Baynard, T., Massoli, P., Sierau, B., Bates, T. S., Quinn, P. K., Lovejoy, E. R., & Ravishankara, A. R.
Venue
Aerosol Science and Technology
Published
2008-10-23
Volume
42
Issue
12
Pages
1033-1041
ISSN
  • 0278-6826 (ISSN-L)
  • 1521-7388
OpenAlex
W4255632308
Cited by
235
References
30
FWCI
12.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.