Deposition of Tobacco Smoke Particles in a Low Ventilation Room
Open accessThe DOI matches its Crossref record.
Abstract
Deposition on indoor surfaces is an important removal mechanism for tobacco smoke particles. We report measurements of deposition rates of environmental tobacco smoke particles in a room-size chamber. The deposition rates were determined from the changes in measured concentrations by correcting for the effects of coagulation and ventilation. The airflow turbulent intensity parameter was determined independently by measuring the air velocities in the chamber. Particles with diameters < 0.25 μm coagulate to form larger particles of sizes between 0.25 and 0.5 μm. The effect of coagulation on the particles > 0.5 μm was found to be negligible. Comparison between our measurements and calculations using the theory of Crump and Seinfeld (1981) showed smaller measured deposition rates for particles from 0.1 to 0.3 μm in diameter and greater measured deposition rates for particles larger than 0.6 μm at three mixing intensities. Comparison of Nazaroff and Cass' model (1989a) for natural convection flow showed good agreement with the measurements for particles > 0.1 μm in diameter; however, measured deposition rates exceeded model predictions by a factor of approximately 4 for particles in size range of 0.05–0.1 μm in diameter. These results were used to predict deposition of sidestream smoke particles on interior surfaces. Calculations predict that in 10 hours after smoking one cigarette, 22% of total sidestream particles by mass will deposit on interior surfaces at 0.03 air change per hour (ACH), 6% will deposit at 0.5 ACH, and 3% will deposit at 1 ACH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416
Self-citationParticle size characterization and emission rates during indoor activities in a house
Hussein, T., Glytsos, T., Ondráček, J., Dohányosová, P., Ždímal, V., Hämeri, K., Lazaridis, M., Smolík, J., & Kulmala, M. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.03.053 · Cited by 271
Performance and costs of particle air filtration technologies: Air filtration technology
Fisk, W. J., Faulkner, D., Palonen, J., & Seppanen, O. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01136.x · Cited by 242
“Data from Xu et al. (1994) Unpublished data from Thatcher, Lawrence Berkeley National Lab.”
MethodResultParticle deposition indoors: a review
Lai, A. C. K. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01159.x · Cited by 226
Indoor Particulate Matter during HOMEChem: Concentrations, Size Distributions, and Exposures
Patel, S., Sankhyan, S., Boedicker, E. K., DeCarlo, P. F., Farmer, D. K., Goldstein, A. H., Katz, E. F., Nazaroff, W. W., Tian, Y., Vanhanen, J., et al. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c00740 · Cited by 214
Self-citation
Metadata
- Authors
- Xu, M., Nematollahi, M., Sextro, R. G., Gadgil, A. J., & Nazaroff, W. W.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1994-01
- Volume
- 20
- Issue
- 2
- Pages
- 194-206
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W1984910072
- Cited by
- 109
- References
- 0
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deposition of Tobacco Smoke Particles in a Low Ventilation Room. https://app.cochat.ai/papers/10.1080/02786829408959676
- The paper
- Xu, M., Nematollahi, M., Sextro, R. G., Gadgil, A. J., & Nazaroff, W. W. (1994). Deposition of Tobacco Smoke Particles in a Low Ventilation Room. Aerosol Science and Technology. https://doi.org/10.1080/02786829408959676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.