Calibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols
Open accessThe DOI matches its Crossref record.
Abstract
Data on light absorption by atmospheric particles are scarce relative to the need for global characterization. Most of the existing data come from methods that measure the change in light transmission through a filter on which particles are collected. We present a calibration of a recently developed filter-based instrument for continuous measurement of light absorption (model PSAP, Radiance Research, Seattle, WA) that has been incorporated in several measurement programs. This calibration uses a reference absorption determined as the difference between light extinction and light scattering by unaltered (suspended) particles. In addition, we perform the same calibration for two other common filter-based methods: an Integrating Plate and the Hybrid Integrating Plate System. For each method, we assess the responses to both particulate light scattering and particulate light absorption. We find that each of the instruments exhibits a significant response to nonabsorbing aerosols and overestimates absorption at 550 nm by suspended particles by about 20-30%. We also present correction factors for the use of the PSAP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Items 101–110 of 110
Linke, C., Möhler, O., Veres, A., Mohácsi, Á., Bozóki, Z., Szabó, G., & Schnaiter, M. (2006) · Atmospheric Chemistry and Physics · doi:10.5194/acp-6-3315-2006 · Cited by 163
Multi-wavelength optical measurement to enhance thermal/optical analysis for carbonaceous aerosol
Chen, L.-W. A., Chow, J. C., Wang, X. L., Robles, J. A., Sumlin, B. J., Lowenthal, D. H., Zimmermann, R., & Watson, J. G. (2015) · Atmospheric Measurement Techniques · doi:10.5194/amt-8-451-2015 · Cited by 161
“…infer the light absorption coefficient (babs), analogous to the principle of optical absorption monitors such as the aethalome- ter (Hansen et al., 1984), particle-soot absorption photometer (PSAP; Bond et al., 1999), and the multi-angle absorption photometer (MAAP; Petzold and Schönlinner, 2004).”
BackgroundPan-Arctic seasonal cycles and long-term trends of aerosol properties from 10 observatories
Schmale, J., Sharma, S., Decesari, S., Pernov, J., Massling, A., Hansson, H.-C., von Salzen, K., Skov, H., Andrews, E., Quinn, P. K., et al. (2022) · Atmospheric Chemistry and Physics · doi:10.5194/acp-22-3067-2022 · Cited by 133
“PSAP: λ= 530 nm converted to σap at 550 nm assuming an Ångström exponent of 1 PSAP 3-λ 10 m2 g−1 Bond et al. (1999); Ogren (2010)”
BackgroundInfluentialEckhardt, S., Hermansen, O., Grythe, H., Fiebig, M., Stebel, K., Cassiani, M., Baecklund, A., & Stohl, A. (2013) · Atmospheric Chemistry and Physics · doi:10.5194/acp-13-8401-2013 · Cited by 128
“We are aware that there are uncertainties in the EBC data, which are related to the conversion, the sampling statistics and scattering correction (Bond et al., 1999); as most analyses are of comparative nature, systematic errors are expected to cancel out.”
BackgroundBates, T. S., Quinn, P. K., Johnson, J. E., Corless, A., Brechtel, F. J., Stalin, S. E., Meinig, C., & Burkhart, J. F. (2013) · Atmospheric Measurement Techniques · doi:10.5194/amt-6-2115-2013 · Cited by 119
“The light absorption coefficient is proportional to the rate of decrease of light transmittance divided by the flow rate of air through the filter (Bond et al., 1999).”
BackgroundMethodYttri, K. E., Lund Myhre, C., Eckhardt, S., Fiebig, M., Dye, C., Hirdman, D., Ström, J., Klimont, Z., & Stohl, A. (2014) · Atmospheric Chemistry and Physics · doi:10.5194/acp-14-6427-2014 · Cited by 93
“The influence of particle scattering has been corrected according to Bond et al. (1999). Assuming that all the light absorption measured is due to BC and that all BC has the same light absorption efficiency, σap values can be converted to equivalent BC (EBC) mass concentrations when divided by the mass absorption cros…”
BackgroundInfluentialAliabadi, A. A., Staebler, R. M., & Sharma, S. (2015) · Atmospheric Chemistry and Physics · doi:10.5194/acp-15-2651-2015 · Cited by 66
Pikridas, M., Bezantakos, S., Močnik, G., Keleshis, C., Brechtel, F., Stavroulas, I., Demetriades, G., Antoniou, P., Vouterakos, P., Argyrides, M., et al. (2019) · Atmospheric Measurement Techniques · doi:10.5194/amt-12-6425-2019 · Cited by 60
CAMP: an instrumented platform for balloon-borne aerosol particle studies in the lower atmosphere
Pilz, C., Düsing, S., Wehner, B., Müller, T., Siebert, H., Voigtländer, J., & Lonardi, M. (2022) · Atmospheric Measurement Techniques · doi:10.5194/amt-15-6889-2022 · Cited by 20
“(4) In addition, Bond et al. (1999) and Ogren (2010) introduced two constants,K1= 0.02± 0.02 andK2= 1.22± 0.2, to correct for loading and enhancement by deposited scattering and absorbing particles, respectively.”
BackgroundInfluentialKinase, T., Taketani, F., Takigawa, M., Zhu, C., Kim, Y., Mordovskoi, P., & Kanaya, Y. (2025) · Atmospheric Chemistry and Physics · doi:10.5194/acp-25-143-2025 · Cited by 4
Metadata
- Authors
- Bond, T. C., Anderson, T. L., & Campbell, D.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1999-06
- Volume
- 30
- Issue
- 6
- Pages
- 582-600
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W1988880047
- Cited by
- 1,022
- References
- 0
- FWCI
- 15.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.