Bio-Microarray Fabrication Techniques—A Review
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Microarrays with biomolecules (e.g., DNA and proteins), cells, and tissues immobilized on solid substrates are important tools for biological research, including genomics, proteomics, and cell analysis. In this paper, the current state of microarray fabrication is reviewed. According to spot formation techniques, methods are categorized as "contact printing" and "non-contact printing." Contact printing is a widely used technology, comprising methods such as contact pin printing and microstamping. These methods have many advantages, including reproducibility of printed spots and facile maintenance, as well as drawbacks, including low-throughput fabrication of arrays. Non-contact printing techniques are newer and more varied, comprising photochemistry-based methods, laser writing, electrospray deposition, and inkjet technologies. These technologies emerged from other applications and have the potential to increase microarray fabrication throughput; however, there are several challenges in applying them to microarray fabrication, including interference from satellite drops and biomolecule denaturization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Schena, M., Shalon, D., Davis, R. W., & Brown, P. O. (1995) · Science · doi:10.1126/science.270.5235.467 · Cited by 9,609
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Tissue microarrays for high-throughput molecular profiling of tumor specimens
Kononen, J., Bubendorf, L., Kallionimeni, A., Bärlund, M., Schraml, P., Leighton, S., Torhorst, J., Mihatsch, M. J., Sauter, G., & Kallionimeni, O.-P. (1998) · Nature Medicine · doi:10.1038/nm0798-844 · Cited by 4,099
Piner, R. D., Zhu, J., Xu, F., Hong, S., & Mirkin, C. A. (1999) · Science · doi:10.1126/science.283.5402.661 · Cited by 3,052
Fundamentals of Microfabrication
(2016) · Micromechatronics · doi:10.1201/b15830-17 · Cited by 2,109
Fundamentals of Microfabrication
Madou, M. J. (2018) · CRC Press eBooks · doi:10.1201/9781482274004 · Cited by 2,020
Kumar, A., & Whitesides, G. M. (1993) · Applied Physics Letters · doi:10.1063/1.110628 · Cited by 1,605
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
Engineering cell shape and function
Singhvi, R., Kumar, A., Lopez, G. P., Stephanopoulos, G. N., Wang, D. I. C., Whitesides, G. M., & Ingber, D. E. (1994) · Science · doi:10.1126/science.8171320 · Cited by 1,453
Light-generated oligonucleotide arrays for rapid DNA sequence analysis.
Pease, A. C., Solas, D., Sullivan, E. J., Cronin, M. T., Holmes, C. P., & Fodor, S. P. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.11.5022 · Cited by 1,367
Cited by
Lowe, R., Shirley, N., Bleackley, M., Dolan, S., & Shafee, T. (2017) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1005457 · Cited by 1,176
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Bhardwaj, R., Fang, X., Somasundaran, P., & Attinger, D. (2010) · Langmuir · doi:10.1021/la9047227 · Cited by 499
A Review of Graphene‐Based Electrochemical Microsupercapacitors
Xiong, G., Meng, C., Reifenberger, R. G., Irazoqui, P. P., & Fisher, T. S. (2014) · Electroanalysis · doi:10.1002/elan.201300238 · Cited by 365
A Nanoengineering Approach for Investigation and Regulation of Protein Immobilization
Tan, Y. H., Liu, M., Nolting, B., Go, J. G., Gervay-Hague, J., & Liu, G.-Y. (2008) · ACS Nano · doi:10.1021/nn800508f · Cited by 312
The Physical and Biochemical Properties of the Extracellular Matrix Regulate Cell Fate
(2018) · Current Topics in Developmental Biology · doi:10.1016/bs.ctdb.2018.02.002 · Cited by 286
“Toward this objective, microprinting technologies that were originally developed for DNA and protein microarrays have been adapted to build 3D cellular environments with microscale control of the scaffold design (Barbulovic-Nad et al., 2006; MacBeath & Schreiber, 2000).”
MethodInkjet printing of macromolecules on hydrogels to steer neural stem cell differentiation
Ilkhanizadeh, S., Teixeira, A. I., & Hermanson, O. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.018 · Cited by 246
Tears as a source of biomarkers for ocular and systemic diseases
von Thun und Hohenstein-Blaul, N., Funke, S., & Grus, F. H. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2013.07.015 · Cited by 233
Tissue engineering with the aid of inkjet printers
Campbell, P. G., & Weiss, L. E. (2007) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.7.8.1123 · Cited by 221
“In contrast to simple spot patterns used in array technologies for proteomics and genomics [22] , 2D inject printing of growth factors includes more complex shapes and pattern combinations for broader applications intended to direct behaviors of cell populations.”
Protein microarrays for diagnostic assays
Hartmann, M., Roeraade, J., Stoll, D., Templin, M. F., & Joos, T. O. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2379-z · Cited by 173
Biofunctionalization of Multiplexed Silicon Photonic Biosensors
Puumala, L. S., Grist, S. M., Morales, J. M., Bickford, J. R., Chrostowski, L., Shekhar, S., & Cheung, K. C. (2022) · Biosensors · doi:10.3390/bios13010053 · Cited by 55
“This technique offers low sample consumption and good resolution, with minimum spot sizes in the range of 1–100 μm, depending on the pin geometry [33,77,313].”
BackgroundMethodInfluentialWhole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.532767 · Cited by 52
Metadata
- Authors
- Barbulovic-Nad, I., Lucente, M., Sun, Y., Zhang, M., Wheeler, A. R., & Bussmann, M.
- Venue
- Critical Reviews in Biotechnology
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 26
- Issue
- 4
- Pages
- 237-259
- ISSN
- 0738-8551 (ISSN-L)
- 1549-7801
- OpenAlex
- W2062878272
- Cited by
- 376
- References
- 46
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.