On-line soft sensing in upstream bioprocessing
Open accessThe DOI matches its Crossref record; 150 of the 150 references it cites were found in a registry or an index.
Abstract
This review provides an overview and a critical discussion of novel possibilities of applying soft sensors for on-line monitoring and control of industrial bioprocesses. Focus is on bio-product formation in the upstream process but also the integration with other parts of the process is addressed. The term soft sensor is used for the combination of analytical hardware data (from sensors, analytical devices, instruments and actuators) with mathematical models that create new real-time information about the process. In particular, the review assesses these possibilities from an industrial perspective, including sensor performance, information value and production economy. The capabilities of existing analytical on-line techniques are scrutinized in view of their usefulness in soft sensor setups and in relation to typical needs in bioprocessing in general. The review concludes with specific recommendations for further development of soft sensors for the monitoring and control of upstream bioprocessing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“When developing a software sensor, different techniques could be employed individually or in combination, in parallel or in sequence (Randek and Mandenius 2018; Rathore et al. 2021).”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Randek and Mandenius 2018
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Data-driven Soft Sensors in the process industry
Kadlec, P., Gabrys, B., & Strandt, S. (2009) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.12.012 · Cited by 1,845 · cited 2×
“These models are widely used in academia as well as in industry, especially in the chemical process industries [3].”
BackgroundAdvances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Quality by design for biopharmaceuticals
Rathore, A. S., & Winkle, H. (2009) · Nature Biotechnology · doi:10.1038/nbt0109-26 · Cited by 830 · cited 1×
“control towards optimal process conditions [9].”
Soft Sensors for Monitoring and Control of Industrial Processes
(2007) · Advances in Industrial Control · doi:10.1007/978-1-84628-480-9 · Cited by 710
A 21st century technique for food control: Electronic noses
Peris, M., & Escuder-Gilabert, L. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.02.009 · Cited by 580
Quality by Design in Biopharmaceuticals
Yang, H. (2016) · doi:10.1201/9781315371726-7 · Cited by 543
Liu, J., Mazumdar, D., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603106 · Cited by 346
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
Applications of Terahertz Spectroscopy in Biosystems
Plusquellic, D. F., Siegrist, K., Heilweil, E. J., & Esenturk, O. (2007) · ChemPhysChem · doi:10.1002/cphc.200700332 · Cited by 310
Application of the near-infrared spectroscopy in the pharmaceutical technology
Jamrógiewicz, M. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.03.009 · Cited by 299 · cited 1×
“Moreover, the same MVDA model as built on the laboratory scale can be used in a scaled-up process [80].”
MethodWalther, J., Godawat, R., Hwang, C., Abe, Y., Sinclair, A., & Konstantinov, K. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.05.010 · Cited by 238
Soft sensors in bioprocessing: A status report and recommendations
Luttmann, R., Bracewell, D. G., Cornelissen, G., Gernaey, K. V., Glassey, J., Hass, V. C., Kaiser, C., Preusse, C., Striedner, G., & Mandenius, C. (2012) · Biotechnology Journal · doi:10.1002/biot.201100506 · Cited by 238 · cited 3×
“Data acquired at a specific process/plant are used to build the model with established statistical and chemometric methods, such as partial least squares (PLS), principal component analysis (PCA) and artificial neural networks [4].”
BackgroundMethodSelf-citationHigh-speed high-performance liquid chromatography of peptides and proteins
Chen, H., & Horváth, C. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(94)01254-c · Cited by 237 · cited 1×
“Although HPLC is well-established in industry for analyzing process samples, it is seldom used for on-line monitoring and control of bioprocesses, mostly due to limited robustness and modest resolution of complex biological samples [96].”
BackgroundBioprocess control: Advances and challenges
Alford, J. S. (2006) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2006.05.039 · Cited by 232
End-to-end integrated fully continuous production of recombinant monoclonal antibodies
Godawat, R., Konstantinov, K., Rohani, M., & Warikoo, V. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.06.393 · Cited by 226
Real-time bioprocess monitoring
Vojinović, V., Cabral, J. M. S., & Fonseca, L. P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.07.059 · Cited by 221
Choi, J.-I., & Lee, S. Y. (1999) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19990305)62:5<501::aid-bit1>3.0.co;2-y · Cited by 219
Process analytical technology (PAT) for biopharmaceuticals
Glassey, J., Gernaey, K. V., Clemens, C., Schulz, T. W., Oliveira, R., Striedner, G., & Mandenius, C. (2011) · Biotechnology Journal · doi:10.1002/biot.201000356 · Cited by 211 · cited 2×
“Soft sensors may indeed exert a strong impact on the control of biopharmaceutical production, leading to improved product quality, process automation, resource utilization and compliance with regulatory demands [11].”
BackgroundSelf-citationWorkman, Koch, M., & Veltkamp, D. (2005) · Analytical Chemistry · doi:10.1021/ac050620o · Cited by 203
Advances in on-line monitoring and control of mammalian cell cultures: Supporting the PAT initiative
Teixeira, A. P., Oliveira, R., Alves, P. M., & Carrondo, M. J. T. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.05.003 · Cited by 193
Cervera, A. E., Petersen, N., Lantz, A. E., Larsen, A., & Gernaey, K. V. (2009) · Biotechnology Progress · doi:10.1002/btpr.280 · Cited by 175 · cited 1×
“However, the NIR and MIR spectroscopy are associated with several difficulties that can influence the quality of the model predictions such as variations during the culture, disturbances due to the sampling techniques and model robustness [81].”
BackgroundBiomass measurement online: the performance of in situ measurements and software sensors
Kiviharju, K., Salonen, K., Moilanen, U., & Eerikäinen, T. (2008) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-008-0346-5 · Cited by 173
Whelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159
Sun, Y., Quyen, T. L., Hung, T. Q., Chin, W. H., Wolff, A., & Bang, D. D. (2015) · Lab on a Chip · doi:10.1039/c4lc01459f · Cited by 158
Application of mechanistic models to fermentation and biocatalysis for next-generation processes
Gernaey, K. V., Lantz, A. E., Tufvesson, P., Woodley, J. M., & Sin, G. (2010) · Trends in biotechnology · doi:10.1016/j.tibtech.2010.03.006 · Cited by 155 · cited 1×
“The mechanistic models are built on physical, chemical and biological insights and an understanding of the transformation processes in the production organisms [113].”
BackgroundPeris, M., & Escuder‐Gilabert, L. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.048 · Cited by 155
In situ sensor techniques in modern bioprocess monitoring
Beutel, S., & Henkel, S. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3470-5 · Cited by 154
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
In‐situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation
Arnold, S. A., Crowley, J., Woods, N., Harvey, L. M., & McNeil, B. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10738 · Cited by 149 · cited 2×
“glucose, ammonia, glutamine, glycerol, lactate, ethanol and total protein), as well as cell numbers or biomass [78,79] can be derived from one spectrum.”
BackgroundBerry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Software sensors in bioprocess engineering
Chéruy, A. (1997) · Journal of Biotechnology · doi:10.1016/s0168-1656(96)01644-6 · Cited by 142
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134 · cited 1×
“predictions and validation is difficult [83].”
Arnold, S. A., Gaensakoo, R., Harvey, L. M., & McNeil, B. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10383 · Cited by 126 · cited 1×
“In situ NIR/MIR spectroscopy with multivariate data analysis (MVDA) of spectra meets many of the expectations of an ideal soft sensor: samples do not need to be removed, data are generated continuously in real-time, additional reagents are not required and it is easy to install and sterilize the in situ probe; all qua…”
BackgroundRathore, A. S., Yu, M., Yeboah, S., & Sharma, A. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21759 · Cited by 126
In-situ microscopy: Online process monitoring of mammalian cell cultures
Joeris, K., Frerichs, J.-G., Konstantinov, K., & Scheper, T. H. (2002) · Cytotechnology · doi:10.1023/a:1021170502775 · Cited by 125 · cited 2×
“In addition, an ISM probe can conveniently be sterilized in-place, allowing the probe to stay in the reactor during the entire process [86].”
BackgroundMulti-wavelength single-molecule fluorescence analysis of transcription mechanisms
Friedman, L. J., & Gelles, J. (2015) · Methods · doi:10.1016/j.ymeth.2015.05.026 · Cited by 116 · cited 1×
“Drawbacks with the technique are that the signals of different components often overlap, and images often have low signal-to-noise ratio which makes discrimination of real signals from noise a challenge [95].”
BackgroundInternational Council for Harmonisation (ICH)
(2019) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789813278851_0047 · Cited by 114
Production of Biologicals from Animal Cells in Culture
(1991) · Elsevier eBooks · doi:10.1016/c2013-0-04581-1 · Cited by 112
Workman, Veltkamp, D. J., Doherty, S., Anderson, B. B., Creasy, K. E., Koch, M., Tatera, J. F., Robinson, A. L., Bond, L., Burgess, L. W., et al. (1999) · Analytical Chemistry · doi:10.1021/a1990007s · Cited by 111
Ödman, P., Johansen, C. L., Olsson, L., Gernaey, K. V., & Lantz, A. E. (2009) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2009.08.018 · Cited by 107 · cited 1×
“Yeast fermentation producing biomass and ethanol monitored using in situ multi wavelength fluorimetry Models based on PARAFAC, PLS and PCA are used to estimate key process parameters (biomass, ethanol and glucose) [89]”
MethodOptical sensor systems for bioprocess monitoring
Marose, S. (1999) · Trends in biotechnology · doi:10.1016/s0167-7799(98)01247-5 · Cited by 102
von Stosch, M., Davy, S., Francois, K., Galvanauskas, V., Hamelink, J., Luebbert, A., Mayer, M., Oliveira, R., O'Kennedy, R., Rice, P., et al. (2014) · Biotechnology Journal · doi:10.1002/biot.201300385 · Cited by 102
Sandnes, J. M., Ringstad, T., Wenner, D., Heyerdahl, P. H., Källqvist, T., & Gislerød, H. R. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.08.034 · Cited by 99 · cited 1×
“This soft sensor-like setup has the potential to be extended to other on-line sensors in microalgae cultures, such as NIR spectroscopy [128] and off-gas analysis [129].”
BackgroundNavrátil, M., Norberg, A., Lembrén, L., & Mandenius, C. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.07.013 · Cited by 87 · cited 2×
“glucose, ammonia, glutamine, glycerol, lactate, ethanol and total protein), as well as cell numbers or biomass [78,79] can be derived from one spectrum.”
BackgroundMethodSelf-citationA flow injection flow cytometry system for on-line monitoring of bioreactors
Zhao, R., Natarajan, A., & Srienc, F. (1999) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19990305)62:5<609::aid-bit13>3.0.co;2-c · Cited by 86
mRNA display selection and solid‐phase synthesis of Fc‐binding cyclic peptide affinity ligands
Menegatti, S., Hussain, M., Naik, A. D., Carbonell, R. G., & Rao, B. M. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24760 · Cited by 85 · cited 1×
“tives for harsh conditions and long-term use [104,105].”
BackgroundMini‐review: soft sensors as means for PAT in the manufacture of bio‐therapeutics
Mandenius, C., & Gustavsson, R. (2015) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4477 · Cited by 84 · cited 1×
“To be really useful as tools in bioprocess monitoring, the soft sensors should have capacity to measure such critical process and quality parameters that existing in-process methods fail to monitor [5].”
Self-citationSkibsted, E., Lindemann, C., Roca, C., & Lisbeth Olsson, A. (2001) · Journal of Biotechnology · doi:10.1016/s0168-1656(01)00257-7 · Cited by 84 · cited 1×
“2D-fluorescence spectroscopy shows high specificity and sensitivity for the fluorophores, it can, as NIR/MIR spectroscopy, be applied in situ and non-invasively with fiber-optical probes, it measures in real-time, and can be sterilized in place [93,94].”
BackgroundReal-Time on-Line Flow Cytometry for Bioprocess Monitoring
Broger, T., Odermatt, R. P., Huber, P., & Sonnleitner, B. (2011) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2011.05.003 · Cited by 83
Enzyme-catalyzed synthesis of sugar-containing monomers and linear polymers
Park, O.-J., Kim, D., & Dordick, J. S. (2000) · Biotechnology and Bioengineering · doi:10.1002/1097-0290(20001020)70:2<167::aid-bit6>3.0.co;2-p · Cited by 83
In-line and real-time prediction of recombinant antibody titer by in situ Raman spectroscopy
André, S., Cristau, L. S., Gaillard, S., Devos, O., Calvosa, É., & Duponchel, L. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.08.050 · Cited by 82
Modelling and optimization of a recombinant BHK-21 cultivation process using hybrid grey-box systems
Teixeira, A. P., Cunha, A. E., Clemente, J. J., Moreira, J. L., Cruz, H., Alves, P. M., Carrondo, M. J. T., & Oliveira, R. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.04.024 · Cited by 82 · cited 1×
“The method is not implemented online [119]”
Fermentanomics: Monitoring Mammalian Cell Cultures with NMR Spectroscopy
Bradley, S. A., Ouyang, A., Purdie, J., Smitka, T. A., Wang, T., & Kaerner, A. (2010) · Journal of the American Chemical Society · doi:10.1021/ja101962c · Cited by 80
Two-dimensional fluorescence spectroscopy: A novel approach for controlling fed-batch cultivations
Hantelmann, K., Kollecker, M., Hüll, D., Hitzmann, B., & Scheper, T. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.07.016 · Cited by 80
Binding site on human immunoglobulin G for the affinity ligand HWRGWV
Yang, H., Gurgel, P. V., Williams, D. K., Bobay, B. G., Cavanagh, J., Muddiman, D. C., & Carbonell, R. G. (2010) · Journal of Molecular Recognition · doi:10.1002/jmr.967 · Cited by 80 · cited 1×
“tives for harsh conditions and long-term use [104,105].”
BackgroundA review of non-invasive optical-based image analysis systems for continuous bioprocess monitoring
Höpfner, T., Bluma, A., Rudolph, G., Lindner, P., & Scheper, T. (2010) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-009-0319-8 · Cited by 78 · cited 1×
“cells and their state in a culture have been shown in a number of studies in academia and industry during the past 15 years (see, reviews by [85] and [33]).”
BackgroundSurribas, A., Geißler, D., Gierse, A., Scheper, T. H., Hitzmann, B., Montesinos, J. L. G., & Valero, F. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2006.01.002 · Cited by 77 · cited 1×
“Also, monitoring the concentration of glycerol, methanol and heterologous proteins in Pichia pastoris [90], and the human basic fibroblast growth factor in Escherichia coli [91], together with IgG4 in CHO cell cultivations [92].”
BackgroundHybrid process models for process optimisation, monitoring and control
Galvanauskas, V., Simutis, R., & L�bbert, A. (2004) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-004-0385-x · Cited by 76 · cited 1×
“Demonstrates the feasibility of combining data-driven models with first principle models [118]”
MethodMeasurement, Monitoring, Modelling and Control of Bioprocesses
Mandenius, C., & Titchener-Hooker, N. J. (2013) · Advances in biochemical engineering, biotechnology · doi:10.1007/978-3-642-36838-7 · Cited by 75
Self-citationWang, Q., Li, Z., Ma, Z., & Liang, L. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.109 · Cited by 74
2-Dimensional fluorescence spectroscopy for on-line bioprocess monitoring
Lindemann, C., Marose, S., Nielsen, H. O., & Scheper, T. H. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00195-6 · Cited by 74 · cited 1×
“2D-fluorescence spectroscopy shows high specificity and sensitivity for the fluorophores, it can, as NIR/MIR spectroscopy, be applied in situ and non-invasively with fiber-optical probes, it measures in real-time, and can be sterilized in place [93,94].”
BackgroundIn-situ imaging sensors for bioprocess monitoring: state of the art
Bluma, A., Höpfner, T., Lindner, P., Rehbock, C., Beutel, S., Riechers, D., Hitzmann, B., & Scheper, T. H. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4181-y · Cited by 72 · cited 1×
“cells and their state in a culture have been shown in a number of studies in academia and industry during the past 15 years (see, reviews by [85] and [33]).”
BackgroundThe development and applications of thermal biosensors for bioprocess monitoring
Ramanathan, K., Rank, M., Svitel, J., Dzgoev, A., & Danielsson, B. (1999) · Trends in biotechnology · doi:10.1016/s0167-7799(99)01378-5 · Cited by 71
Dielectric monitoring of growth and sporulation of Bacillus thuringiensis
Sarrafzadeh, M., Belloy, L., Esteban, G., Navarro, J. M., & Ghommidh, C. (2005) · Biotechnology Letters · doi:10.1007/s10529-005-2543-x · Cited by 69
Mandenius, C., Wang, R., Aldén, A., Bergström, G., Thébault, S., Lutsch, C., & Ohlson, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.005 · Cited by 69
Self-citationSandor, M., Rüdinger, F., Bienert, R., Grimm, C., Solle, D., & Scheper, T. H. (2013) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2013.08.002 · Cited by 68 · cited 1×
“However, also here, the abovementioned models and algorithms need extensive offline model calibration [28,135,136].”
BackgroundHaack, M. B., Lantz, A. E., & Lisbeth Olsson, A. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.05.009 · Cited by 67
Culture temperature modulates aggregation of recombinant antibody in cho cells
Gomez, N., Subramanian, J., Ouyang, J., Nguyen, M. D. H., Hutchinson, M., Sharma, V. K., Lin, A. A., & Yuk, I. H. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.23288 · Cited by 65 · cited 1×
“monoclonal antibody, growth factor) [50,99,100].”
Guez, J. S., Cassar, J. P., Wartelle, F., Dhulster, P., & Suhr, H. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.04.028 · Cited by 64 · cited 1×
“The performance of ISM is in several processes considered reliable, stable and robust enough for long-term monitoring [32,86].”
BackgroundAutomated Measurement and Monitoring of Bioprocesses: Key Elements of the M3C Strategy
Sonnleitner, B. (2012) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2012_173 · Cited by 61
Carrondo, M. J. T., Alves, P. M., Carinhas, N., Glassey, J., Hesse, F., Merten, O., Micheletti, M., Noll, T., Oliveira, R., Reichl, U., et al. (2012) · Biotechnology Journal · doi:10.1002/biot.201200226 · Cited by 59
Self-citationPfeiffer, S. A., & Nagl, S. (2015) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/3/3/034003 · Cited by 59
Calorimetric control for high cell density cultivation of a recombinant Escherichia coli strain
Biener, R., Steinkämper, A., & Hofmann, J. F.-X. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.004 · Cited by 59
Simplified off-gas analyses in animal cell cultures for process monitoring and control purposes
Aehle, M., Kuprijanov, A., Schaepe, S., Simutis, R., & Lübbert, A. (2011) · Biotechnology Letters · doi:10.1007/s10529-011-0686-5 · Cited by 58
Software sensors for fermentation processes
Sundström, H., & Enfors, S. (2007) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-007-0157-5 · Cited by 57 · cited 1×
“equations estimated key process parameters (l, oxygen transfer and biomass) [115]”
BackgroundMonitoring of microalgal cultivations with on-line, flow-through microscopy
Havlik, I., Reardon, K. F., Ünal, M., Lindner, P., Prediger, A., Babitzky, A., Beutel, S., & Scheper, T. (2013) · Algal Research · doi:10.1016/j.algal.2013.04.001 · Cited by 56 · cited 1×
“For on-line monitoring of microalgae cultures, ISM supported by advanced signal imaging processing appears to be a powerful means for capturing critical data on-line [127] showed how the ISM placed in a flow-through chamber connected to photobioreactors with Chlamydomonas and Chlorella cultures could be used to estima…”
MethodBergström, G., Christoffersson, J., Schwanke, K., Zweigerdt, R., & Mandenius, C.-F. (2015) · Lab on a Chip · doi:10.1039/c5lc00449g · Cited by 56
Self-citationJezierski, S., Belder, D., & Nagl, S. (2012) · Chemical Communications · doi:10.1039/c2cc38093e · Cited by 56
Bioprocess Iterative Batch-to-Batch Optimization Based on Hybrid Parametric/Nonparametric Models
Teixeira, A. P., Clemente, J. J., Cunha, A. E., Carrondo, M. J. T., & Oliveira, R. (2006) · Biotechnology Progress · doi:10.1021/bp0502328 · Cited by 52 · cited 1×
“avoiding some of their disadvantages [124].”
Instrumentation of Biotechnological Processes
Sonnleitner, B. (1999) · Advances in biochemical engineering, biotechnology · doi:10.1007/3-540-48773-5_1 · Cited by 52
Rathore, A. S., Wood, R., Sharma, A., & Dermawan, S. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21982 · Cited by 51
Luchner, M., Gutmann, R., Bayer, K., Dunkl, J., Hansel, A., Herbig, J., Singer, W., Strobl, F., Winkler, K., & Striedner, G. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24579 · Cited by 50
Continuous weak-affinity immunosensing
Ohlson, S., Jungar, C., Strandh, M., & Mandenius, C. (2000) · Trends in biotechnology · doi:10.1016/s0167-7799(99)01411-0 · Cited by 49
Self-citationPetersen, N., Ödman, P., Padrell, A. E. C., Stocks, S., Lantz, A. E., & Gernaey, K. V. (2010) · Biotechnology Progress · doi:10.1002/btpr.288 · Cited by 48
Glassey, J. (2012) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2012_171 · Cited by 47 · cited 1×
“The data-driven models, on the other hand, are entirely based on empirical observations of the actual process [122].”
BackgroundGolabgir, A., & Herwig, C. (2016) · Chemie Ingenieur Technik · doi:10.1002/cite.201500101 · Cited by 47 · cited 1×
“equations for estimation of cell specific variables [121] CRITICAL REVIEWS IN BIOTECHNOLOGY 113”
MethodLee, C.-Y., Wu, K.-Y., Su, H.-L., Hung, H.-Y., & Hsieh, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.009 · Cited by 47
Experience in using an ethanol sensor to control molasses feed-rates in baker's yeast production
Axelsson, J. P., Mandenius, C. F., Holst, O., Hagander, P., & Mattìasson, B. (1988) · Bioprocess and Biosystems Engineering · doi:10.1007/bf00372854 · Cited by 46
Self-citationWarth, B., Rajkai, G., & Mandenius, C. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.02.023 · Cited by 45
Self-citationMelcher, M., Scharl, T., Spangl, B., Luchner, M., Cserjan, M., Bayer, K., Leisch, F., & Striedner, G. (2015) · Biotechnology Journal · doi:10.1002/biot.201400790 · Cited by 45 · cited 1×
“coli fed-batch cultivation producing recombinant protein using online 2D fluorescence and stands bioreactor sensors The combination of the two data-driven techniques, ANN and random forest modeling, show good capacity to estimate key information [117]”
MethodBuczkowska, A., Nery, E. W., Górski, Ł., Zamojska, A., Szewczyk, K. W., Wróblewski, W., & Ciosek, P. (2010) · Talanta · doi:10.1016/j.talanta.2010.02.039 · Cited by 45
Ehgartner, D., Sagmeister, P., Herwig, C., & Wechselberger, P. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4469 · Cited by 45 · cited 1×
“Accurate estimation of cell density [18]”
Cimander, C., Bachinger, T., & Mandenius, C. (2003) · Journal of Biotechnology · doi:10.1016/s0168-1656(03)00121-4 · Cited by 44 · cited 1×
“In situ NIR/MIR spectroscopy with multivariate data analysis (MVDA) of spectra meets many of the expectations of an ideal soft sensor: samples do not need to be removed, data are generated continuously in real-time, additional reagents are not required and it is easy to install and sterilize the in situ probe; all qua…”
BackgroundSelf-citationJohnson-Chavarria, E. M., Agrawal, U., Tanyeri, M., Kuhlman, T. E., & Schroeder, C. M. (2014) · Lab on a Chip · doi:10.1039/c4lc00057a · Cited by 43
Calorimetric bioprocess monitoring by small modifications to a standard bench-scale bioreactor
Schubert, T., Breuer, U., Harms, H., & Maskow, T. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.02.013 · Cited by 43
Krishnamoorthy, G., Carlen, E. T., Bomer, J. G., Wijnperlé, D., de Boer, H. L., van den Berg, A., & Schasfoort, R. B. M. (2010) · Lab on a Chip · doi:10.1039/c000705f · Cited by 43
Carotenoid Production by Bacteria, Microalgae, and Fungi
Schweiggert, R. M., & Carle, R. (2016) · Carotenoids · doi:10.1002/9781118622223.ch12 · Cited by 42 · cited 1×
“complex, nutrient supplements, while bacteria and algae have less need for such complex supplements); their responses to environmental changes differ (mammalian cells are more sensitive to nutritional and environmental changes than bacteria, bacteria react fast to changes while algae are slower) [13,14].”
BackgroundRehbock, C., Beutel, S., Brückerhoff, T., Hitzmann, B., Riechers, D., Rudolph, G., Stahl, F., Scheper, T. H., & Friehs, K. (2008) · Chemie Ingenieur Technik · doi:10.1002/cite.200700164 · Cited by 42
Ohadi, K., Legge, R. L., & Budman, H. M. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25339 · Cited by 41 · cited 2×
“spectroscopy [16,120,143], and electrochemical meth-”
MethodRank, M., Danielsson, B. R. G., & Gram, J. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)85020-b · Cited by 39
Diamond-like carbon-gate pH-ISFET
Voigt, H., Schitthelm, F., Lange, T., Kullick, T., & Ferretti, R. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00236-0 · Cited by 38
Real time in-line monitoring of large scale Bacillus fermentations with near-infrared spectroscopy
Alves-Rausch, J., Bienert, R., Grimm, C., & Bergmaier, D. (2014) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2014.09.004 · Cited by 38 · cited 1×
“A score PCA trajectory is generated for the ideal process course [25]”
MethodFahrner, R. L., & Blank, G. S. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00539-7 · Cited by 38
Development of a high resolution UV spectrophotometer for at-line monitoring of bioprocesses
Noui, L., Hill, J., Keay, P. J., Wang, R. Y., Smith, T., Yeung, K. S. Y., Habib, G., & Hoare, M. (2002) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/s0255-2701(01)00122-2 · Cited by 37
Knothe, G. (2010) · Elsevier eBooks · doi:10.1016/b978-1-893997-62-2.50014-0 · Cited by 37
Automated process monitoring of monoclonal antibody production
Paliwal, S. K., Nadler, T. K., Wang, D. I. C., & Regnier, F. E. (1993) · Analytical Chemistry · doi:10.1021/ac00071a005 · Cited by 37 · cited 1×
“monoclonal antibody, growth factor) [50,99,100].”
Bachinger, T., Mårtensson, P., & Mandenius, C. (1998) · Journal of Biotechnology · doi:10.1016/s0168-1656(97)00187-9 · Cited by 37
Self-citationAutomated flow-injection immunosensor based on current pulse capacitive measurements
Erlandsson, D., Teeparuksapun, K., Mattìasson, B., & Hedström, M. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.08.076 · Cited by 36
Applying Mechanistic Models in Bioprocess Development
Fernandes, R. L., Bodla, V. K., Carlquist, M., Heins, A., Lantz, A. E., Sin, G., & Gernaey, K. V. (2012) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2012_166 · Cited by 33 · cited 1×
“Successful mechanistic modeling should be accompanied with procedures for parameter identification, uncertainty analysis and sensitivity analysis [114].”
MethodCapacitive immunosensor for the detection of host cell proteins
Teeparuksapun, K., Hedström, M., Kanatharana, P., Thavarungkul, P., & Mattìasson, B. (2011) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2011.11.004 · Cited by 33
Biomechatronic Design in Biotechnology: A Methodology for Development of Biotechnological Products
Mandenius, C., & Björkman, M. (2011) · Wiley eBooks · doi:10.1002/9781118067147 · Cited by 33 · cited 1×
“These needs should then guide and constrain the design of the soft sensor in order to find the configuration of analytical techniques and computation methods that best meet these needs [12].”
BackgroundSelf-citationSun, J., Stowers, C. C., Boczko, E. M., & Li, D. (2010) · Lab on a Chip · doi:10.1039/c005029f · Cited by 31
Capillary electrophoresis for monitoring bioprocesses
Alhusban, A. A., Breadmore, M. C., & Guijt, R. M. (2013) · Electrophoresis · doi:10.1002/elps.201200646 · Cited by 30
Chopda, V. R., Gomes, J., & Rathore, A. S. (2016) · Biotechnology Journal · doi:10.1002/biot.201500507 · Cited by 30 · cited 1×
“The example provided by [125] illustrates how important a flexible and efficient software configuration is in order to realize soft sensors in practice.”
BackgroundFluorescence‐based soft sensor for at situ monitoring of chinese hamster ovary cell cultures
Ohadi, K., Aghamohseni, H., Legge, R. L., & Budman, H. M. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25222 · Cited by 29 · cited 1×
“spectroscopy [16,120,143], and electrochemical meth-”
Yang, J., Ai, J., Bao, Y., Yuan, Z., Qin, Y., Xie, Y.-W., Tao, D., Fu, D., & Peng, Y. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2013.11.020 · Cited by 29
Jain, G., Jayaraman, G., Kökpınar, Ö., Rinas, U., & Hitzmann, B. (2011) · Biochemical Engineering Journal · doi:10.1016/j.bej.2011.09.005 · Cited by 28 · cited 1×
“Also, monitoring the concentration of glycerol, methanol and heterologous proteins in Pichia pastoris [90], and the human basic fibroblast growth factor in Escherichia coli [91], together with IgG4 in CHO cell cultivations [92].”
BackgroundYoo, S. J., Jeong, D. H., Kim, J. H., & Lee, J. M. (2016) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-016-1602-0 · Cited by 28 · cited 1×
“On-line application with model predictive control would be another potential opportunity [130].”
BackgroundGolabgir, A., Hoch, T., Zhariy, M., & Herwig, C. (2015) · Biotechnology Progress · doi:10.1002/btpr.2176 · Cited by 28
Zimmermann, U., Groves, M. R., Schnabl, H., & Pilwat, G. (1980) · The Journal of Membrane Biology · doi:10.1007/bf01869004 · Cited by 27
On-line observation of dough fermentation by magnetic resonance imaging and volumetric measurements
Goetz, J., Gro�, D., & Koehler, P. (2003) · European Food Research and Technology · doi:10.1007/s00217-003-0796-y · Cited by 27
Gustavsson, R., & Mandenius, C. (2012) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-012-0840-z · Cited by 27
Self-citationMartens, S., Borchert, S., Faber, B. W., Cornelissen, G., & Luttmann, R. (2011) · Engineering in Life Sciences · doi:10.1002/elsc.201000163 · Cited by 27
Zimmermann, U., Pilwat, G., & Schnabl, H. (1979) · Springer eBooks · doi:10.1007/978-3-642-51881-2_65 · Cited by 26
Mahadhy, A., Ståhl-Wernersson, E., Mattìasson, B., & Hedström, M. (2014) · Biotechnology Reports · doi:10.1016/j.btre.2014.06.002 · Cited by 26
Mid‐infrared spectroscopy‐based analysis of mammalian cell culture Parameters
Capito, F., Zimmer, A., & Skudas, R. (2015) · Biotechnology Progress · doi:10.1002/btpr.2026 · Cited by 25
A multi‐bioreactor system for optimal production of malaria vaccines with Pichia pastoris
Fricke, J., Pohlmann, K., Tatge, F., Lang, R., Faber, B. W., & Luttmann, R. (2011) · Biotechnology Journal · doi:10.1002/biot.201000385 · Cited by 24
Lundström, H., Brobjer, M., Österlöf, B., & Moks, T. (1990) · Biotechnology and Bioengineering · doi:10.1002/bit.260361011 · Cited by 23 · cited 1×
“monoclonal antibody, growth factor) [50,99,100].”
An In-Line Flow Injection Optical Biosensor for Real-Time Bioprocess Monitoring
Bracewell, D. G., Gill, A., & Hoare, M. (2002) · Food and Bioproducts Processing · doi:10.1205/09603080252938690 · Cited by 21
High-throughput analysis of animal cell cultures using two-dimensional fluorometry
Teixeira, A. P., Duarte, T. M., Oliveira, R., Carrondo, M. J. T., & Alves, P. M. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.11.015 · Cited by 21 · cited 1×
“Also, monitoring the concentration of glycerol, methanol and heterologous proteins in Pichia pastoris [90], and the human basic fibroblast growth factor in Escherichia coli [91], together with IgG4 in CHO cell cultivations [92].”
BackgroundLüder, C., Lindner, P., Bulnes‐Abundis, D., Lu, S. M., Lücking, T. H., Solle, D., & Scheper, T. H. (2014) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.14.13 · Cited by 21 · cited 2×
“In another example with CHO-cells, ISM and MIR spectroscopy were used for monitoring on-line key parameters of the cells and the media composition [28].”
BackgroundMethodIMAC capture of recombinant protein from unclarified mammalian cell feed streams
Kinna, A., Tolner, B., Miranda, E., Titchener-Hooker, N. J., Nesbeth, D., & Chester, K. A. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25705 · Cited by 21
Zhang, D., Yan, F., Sun, Z., Zhang, Q., Xue, S., & Cong, W. (2014) · Bioresource Technology · doi:10.1016/j.biortech.2014.04.083 · Cited by 20 · cited 1×
“This soft sensor-like setup has the potential to be extended to other on-line sensors in microalgae cultures, such as NIR spectroscopy [128] and off-gas analysis [129].”
BackgroundAn integrated silicon sensor with microfluidic chip for monitoring potassium and pH
Sharma, S., Radomska, A., Triantis, I. F., Michelakis, K., Trzebinski, J., Azarbadegan, A., Field, B. C. T., Toumazou, C., Eames, I., & Cass, A. E. G. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0740-y · Cited by 19
Assawajaruwan, S., Reinalter, J., & Hitzmann, B. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9823-2 · Cited by 19
Construction of an online reduced-spectrum NIR calibration model from full-spectrum data
Dodds, S. A., & Heath, W. P. (2004) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.09.002 · Cited by 17 · cited 1×
“spectroscopy [16,120,143], and electrochemical meth-”
Popova, D., Stonier, A., Pain, D., Titchener-Hooker, N. J., & Farid, S. S. (2016) · Biotechnology Journal · doi:10.1002/biot.201500336 · Cited by 15 · cited 1×
“This could involve a variety of downstream process parameters [141,142].”
BackgroundNear-infrared spectroscopy in upstream bioprocesses
Hoehse, M., Alves-Rausch, J., Prediger, A., Roch, P., & Grimm, C. (2015) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.15.1 · Cited by 13
Quadrupole mass spectrometry for automatic liquid and gas phase analysis in continuous fermentation
Heinzle, E., Furukawa, K., & Dunn, I. J. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)87081-8 · Cited by 12
Bonk, S., Sandor, M., Rüdinger, F., Tscheschke, B., Prediger, A., Babitzky, A., Solle, D., Beutel, S., & Scheper, T. (2011) · BMC Proceedings · doi:10.1186/1753-6561-5-s8-p76 · Cited by 11 · cited 1×
“However, also here, the abovementioned models and algorithms need extensive offline model calibration [28,135,136].”
BackgroundBiomechatronic Design in Biotechnology: A Methodology for Development of Biotechnological Products
Mandenius, C., & Björkman, M. (2011) · Cited by 11
Self-citationIntegrated continuous biomanufacturing: A new paradigm for biopharmaceutical production
Goudar, C. T., Titchener-Hooker, N. J., & Konstantinov, K. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.08.015 · Cited by 11
Determination of pH Value in Biotechnology
Henkel, S., & Beutel, S. (2013) · Chemie Ingenieur Technik · doi:10.1002/cite.201200099 · Cited by 9
The impact of technical failures during cultivation of an inclusion body process
Pekarsky, A., Konopek, V., & Oliver Spadiut, A. (2019) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-019-02158-x · Cited by 8
An approach to potentiometric sensing of sugars: Baker's yeast assisted pH electrode
Voitechovič, E., Kirsanov, D. O., & Legin, A. V. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.11.021 · Cited by 7 · cited 1×
“ods, for example electronic tongues [144], may have”
BackgroundHabib, G., Zhou, Y., & Hoare, M. (2000) · Biotechnology and Bioengineering · doi:10.1002/1097-0290(20001020)70:2<131::aid-bit2>3.0.co;2-l · Cited by 7 · cited 1×
“This could involve a variety of downstream process parameters [141,142].”
BackgroundHorak, J., Hofer, S., Sadler, C., Williams, S., & Lindner, W. F. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4571-1 · Cited by 6
2D fluorescence spectroscopy for real-time aggregation monitoring in upstream processing
Schwab, K., & Hesse, F. (2013) · BMC Proceedings · doi:10.1186/1753-6561-7-s6-p94 · Cited by 4
Regulatory Highlights for March−August 2009
Robinson, D. J. S. (2009) · Organic Process Research & Development · doi:10.1021/op900209q · Cited by 1
Research works printed but not linked: 6
- Federal Drug and Food Administration (FDA), 2004, Guidance for Industry: PAT—a framework for innovative pharmaceutical development, manufacturing, and quality assurance
- Sonnleitner B, 1999, Adv Biochem Eng Biotechnol, 66, 1
- Sonnleitner B, 2013, Adv Biochem Eng Biotechnol, 132, 1
- Chen JY, 2003, Biophys J, 84, 156A
- Fernandes RL, 2012, Adv Biochem Eng Biotechnol, 132, 137
- Glassey J, 2012, Adv Biochem Eng Biotechnol, 132, 167
Cited by
A Review on Soft Sensors for Monitoring, Control, and Optimization of Industrial Processes
Jiang, Y., Yin, S., Dong, J., & Kaynak, O. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3033153 · Cited by 667
“articles [11], [14] and [13] focus only on the applications to polymer processing, the upstream bioprocesses, and the food & beverage processes, respectively.”
BackgroundWang, Y., Zhang, C., Liu, F., Jin, Z., & Xia, X. (2023) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2021.2025035 · Cited by 212
Microbioreactor Systems for Accelerated Bioprocess Development
Hemmerich, J., Noack, S., Wiechert, W., & Oldiges, M. (2018) · Biotechnology Journal · doi:10.1002/biot.201700141 · Cited by 169
“The combination of several measurement techniques to construct so-called soft sensors has been applied several times in bioreactor cultivations [90] and these are also promising tools for MBR cultivations.”
BackgroundMachine learning in bioprocess development: from promise to practice
Helleckes, L. M., Hemmerich, J., Wiechert, W., von Lieres, E., & Grünberger, A. (2023) · Trends in Biotechnology · doi:10.1016/j.tibtech.2022.10.010 · Cited by 163
Gargalo, C. L., Udugama, I., Pontius, K., Lopez, P. C., Nielsen, R. F., Hasanzadeh, A., Mansouri, S. S., Bayer, C., Junicke, H., & Gernaey, K. V. (2020) · Journal of Industrial Microbiology and Biotechnology · doi:10.1007/s10295-020-02308-1 · Cited by 133
“Examples and more details on the development and implementation of soft sensors in the biomanufacturing industry are given in [6, 66].”
Background
Metadata
- Authors
- Randek, J., & Mandenius, C.-F.
- Affiliations
- Linköping University (SE)
- Corresponding author
- Mandenius, Carl-Fredrik
- Venue
- Critical Reviews in Biotechnology
- Publisher
- Informa UK Limited
- Published
- 2017-04-20
- Volume
- 38
- Issue
- 1
- Pages
- 106-121
- ISSN
- 0738-8551 (ISSN-L)
- 1549-7801
- OpenAlex
- W2607276443
- Semantic Scholar
- a592fcd83f19df4381b3afb6dc7cec690504ad4f
- Cited by
- 86
- References
- 149
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 11 · 2023: 9 · 2022: 9 · 2021: 12 · 2020: 12 · 2019: 6 · 2018: 3 · 2017: 3
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- green
- zenodo.org
- Licence
- other-oa
- Locations
- Critical Reviews in Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, other-oa)
- Funders
- EU-Horizon 2020 Marie Sklodowska-Curie Innovative Training Network BIORAPID (643056)
- Linköping University
- Cordis (MSC 643056)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Keywords
- soft sensors, real-time process monitoring, bioprocess control, upstream bioprocessing, process analytical technology, sensor performance, process integration, production economics
- MeSH terms
- Biotechnology, Models, Theoretical, Biosensing Techniques, Bioreactors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.