CoChat

Reproducibility of blood pressure variability, white‐coat effect and dipping pattern in untreated, uncomplicated and newly diagnosed essential hypertension

Open access
Stenehjem, Aud‐E., Os, Ingrid · 2004 · Blood Pressure
Cited by 59

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To investigate the reproducibility of blood pressure (BP) variability, white-coat effect (WCE) and nocturnal dipping pattern in untreated patients with uncomplicated essential hypertension using 24-hour ambulatory BP monitoring (ABPM). METHODS: Seventy-five newly diagnosed, untreated essential hypertensive subjects (54 men, 21 women 47.6 +/- 9.3 years) were recruited for the study based on conventional measured BP from a total of 180 patients referred for ABPM. Of these, 65 patients underwent repeated ABPM after 4 weeks observation without treatment. Reproducibility of BP, nocturnal dipping pattern, WCE and BP variability were assessed using different methods. RESULTS: The average 24-hour BP (140.8 +/- 11.9/91.8 +/- 6.4 vs. 140.5 +/- 14.5/90.7 +/- 7.6 mmHg, ns) or PP (49.6 +/- 10.8 vs. 49.8 +/- 9.8 mmHg, ns) did not change, nor did daytime BP or PP. The WCE diminished significantly during the observation period (reduction in SBP WCE delta8.2 +/- 12.5 mmHg, p < 0.0001, in DBP WCE, delta3.3 +/- 9.2 mmHg, p = 0.008 and in PP WCE delta4.8 +/- 11.2 mmHg, p = 0.002). Variability in SBP, DBP and PP decreased consistently and significantly during the observation period. The nocturnal dipping pattern was unchanged in 82% of the patients. In 12% non-dipping pattern was converted to dipping pattern after repeated measurement. CONCLUSION: Average ABPs are highly reproducible in patients with uncomplicated essential hypertension of limited duration. Similarly, nocturnal dipping pattern reproduced satisfactorily. These measures have important clinical applicability. The white-coat effect as well as variability are greatly attenuated during repeated measurements, and these measures may thus be of less utility in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/08037050410021432

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 59

Metadata

Authors
Stenehjem, A., & Os, I.
Venue
Blood Pressure
Published
2004-01
Volume
13
Issue
4
Pages
214-224
ISSN
  • 0803-7051 (ISSN-L)
  • 1651-1999
OpenAlex
W2164755552
Cited by
59
References
8
FWCI
1.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of blood pressure variability, white‐coat effect and dipping pattern in untreated, uncomplicated and newly diagnosed essential hypertension. https://app.cochat.ai/papers/10.1080/08037050410021432
The paper
Stenehjem, A., & Os, I. (2004). Reproducibility of blood pressure variability, white‐coat effect and dipping pattern in untreated, uncomplicated and newly diagnosed essential hypertension. Blood Pressure. https://doi.org/10.1080/08037050410021432

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.