Global contact lens prescribing 2000-2020
The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Abstract
CLINICAL RELEVANCE: Contact lens prescribing data serve as a benchmark for eye care clinicians in assessing their own prescribing patterns and provide useful contextual information for researchers and the contact lens industry. PURPOSE: To document global trends in contact lens prescribing during the first two decades of this century. METHODS: A longitudinal survey of contact lens prescribing was conducted by asking contact lens practitioners to provide 11 items of information from 10 consecutive contact lens fits between January and March each year from 1996 to 2020, inclusive. RESULTS: Data relating to 406,859 contact lens fits were collected from 71 countries between 1996 and 2020, generating 4.5 million data points. Demographic analysis for 61 nations returning ≥100 fits demonstrated that a majority of lenses (65-70%) were fitted to females. The average age of lens wearers was 30.8 ± 13.9 years for males and 32.5 ± 14.3 years for females. Trend analysis of 20 countries returning prescribing data for ≥13 years between 2000 and 2020 revealed the following: increase in the age of lens wearers; dramatic rise in the extent of fitting silicone hydrogel and daily disposable lenses; increased fitting of soft toric and multifocal lenses; increasing proportion of rigid lens fits in specialist (non-spherical) designs; incomplete provision of near contact lens corrections for contact lens wearing presbyopes; ongoing low levels of extended wear fits; and almost exclusive use of multi-purpose care systems. Daily disposable lenses were used for both full-time and part-time wear, whereas rigid and soft reusable lenses were primarily worn full time. CONCLUSIONS: The evolution of international contact lens fitting over the first two decades of this century is documented. The data presented here may assist all stakeholders in advancing contact lens clinical practice, informing contact lens research, and guiding contact lens manufacturers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The benefits of FFLs are the most pronounced in high myopia and hyperopia [57,58].”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [58]
Citations
Cites
The Incidence of Contact Lens–Related Microbial Keratitis in Australia
Stapleton, F., Keay, L., Edwards, K., Naduvilath, T., Dart, J. K. G., Brian, G., & Holden, B. A. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.04.002 · Cited by 666
Cho, P., Cheung, S. W., & Edwards, M. (2005) · Current Eye Research · doi:10.1080/02713680590907256 · Cited by 596
Poggio, E. C., Glynn, R. J., Schein, O. D., Seddon, J. M., Shannon, M. J., Scardino, V. A., & Kenyon, K. R. (1989) · New England Journal of Medicine · doi:10.1056/nejm198909213211202 · Cited by 572
Refractive Error and Ethnicity in Children
Kleinstein, R. N. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.8.1141 · Cited by 448
Incidence of keratitis of varying severity among contact lens wearers
Morgan, P. B. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.052688 · Cited by 269
Self-citationEvans, B. J. W. (2007) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2007.00488.x · Cited by 223
Deaner, R. O., Geary, D. C., Puts, D. A., Ham, S. A., Kruger, J., Fles, E., Winegard, B., & Grandis, T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049168 · Cited by 190
INTERNATIONAL CONTACT LENS PRESCRIBING IN 2002.
Morgan, P. B., Efron, N., Woods, C. A., JONES, D. A., Tranoudis, Y., van der Worp, E., Helland, M., Buskerud, H. I., Hong, A. Y. C., Barr, J. T., et al. (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb03925.x · Cited by 170
Self-citationOxygen Permeability and Water Content of Silicone Hydrogel Contact Lens Materials
EFRON, N., MORGAN, P. B., CAMERON, I. D., BRENNAN, N. A., & GOODWIN, M. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e31804375ed · Cited by 139
Self-citationHypoxic Effects on the Anterior Eye of High-Dk Soft Contact Lens Wearers Are Negligible
Covey, M., Sweeney, D. F., Terry, R., Sankaridurg, P. R., & Holden, B. A. (2001) · Optometry and Vision Science · doi:10.1097/00006324-200102000-00009 · Cited by 138 · cited 1×
“These lenses are capable of delivering near-natural levels of oxygenation to the cornea during both open- and closed-eye wear and across a wide range of powers, thus minimising hypoxic effects on the anterior eye.(16) These oxygenation-related benefits have largely fuelled the increased fitting of silicone hydrogel le…”
Background
Research works printed but not linked: 5
- Kerr C, Chauhan K. The ACLM contact lens yearbook 2020. Devizes: The Association of Contact Lens Manufacturers; 2020.
- Rowe N, Beasley N, and Adams R. Sport, physical activity and health: future prospects for improving the health of the nation. In: Rowe, N, editor. Driving up participation: the challenge for sport. London: Sport England; 2004. p. 14–26.
- Atkinson TCO. Farewell to hard times? Ophthalmic Optician. 1976;16:919–937.
- 10.1097/00006324-198802000-00005 · doi:10.1097/00006324-198802000-00005
- Morgan PB. Taking stock of the UK contact lens market. Optician. 2009;238(6209):36–38.
Cited by
TFOS Lifestyle: Impact of contact lenses on the ocular surface
Jones, L., Efron, N., Bandamwar, K. L., Barnett, M., Jacobs, D. S., Jalbert, I., Pult, H., Rhee, M. K., Sheardown, H. D., Shovlin, J. P., et al. (2023) · The Ocular Surface · doi:10.1016/j.jtos.2023.04.010 · Cited by 88
Self-citationBCLA CLEAR Presbyopia: Management with contact lenses and spectacles
Morgan, P. B., Efron, N., PAPAS, E. B., Barnett, M., Carnt, N. A., Dutta, D., Hepworth, A., Little, J., Nagra, M., Pult, H., et al. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102158 · Cited by 44
“Details of how this survey is conducted have been published previously [24], and so will not be repeated here in full.”
BackgroundInfluentialSelf-citationMoledina, M., Roberts, H. W., Mukherjee, A. N., Spokes, D. M., Pimenides, D., Stephenson, C., Bassily, R., Rajan, M. S., & Myerscough, J. (2023) · Eye · doi:10.1038/s41433-023-02404-3 · Cited by 35
“This is likely related in part to an absolute increase in CL wearers in all populations but also because trends in CL prescribing show an increase in the average age of CL wearers, who may have more susceptibility to microbial keratitis [15, 19, 28, 29].”
BackgroundBiomaterials for Ophthalmic Applications
Ferraz, M. P. (2022) · Applied Sciences · doi:10.3390/app12125886 · Cited by 23
“They also, economically speaking, represent the most important category and have undergone the most important and complex evolution [18].”
BackgroundContact Lenses Loaded with Melatonin Analogs: A Promising Therapeutic Tool against Dry Eye Disease
Navarro-Gil, F. J., Huete‐Toral, F., Dominguez-Godinez, C., Carracedo, G., & Crooke, A. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11123483 · Cited by 22
“Furthermore, given that the last CL prescribing data showed a dramatic increase in the fitting of daily disposable lenses, the soaked lenses, with a drug release over 5–6 h and are faster and cheaper than other kinds of loaded CLs, seem to be a better alternative [30,52].”
BackgroundInternational trends in daily disposable contact lens prescribing (2000–2023): An update
Morgan, P. B., Efron, N., Woods, C. A., Jones, D., Jones, L., & Nichols, J. J. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102259 · Cited by 21
Self-citationChallenges to the new soft contact lens wearer and strategies for clinical management
Morgan, P. B., & Sulley, A. L. (2023) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2023.101827 · Cited by 20
Self-citationTFOS Lifestyle Report Introduction: A Lifestyle Epidemic - Ocular Surface Disease
Craig, J. P., Alves, M., Wolffsohn, J. S., Downie, L. E., Efron, N., Galor, A., Gomes, J. Á. P., Jones, L., Markoulli, M. P., Stapleton, F. J., et al. (2023) · The Ocular Surface · doi:10.1016/j.jtos.2023.04.014 · Cited by 18
“They are prescribed primarily for the correction of refractive errors [7], including the control of myopia progression, but also for many other reasons, including medical indications.”
BackgroundSelf-citationShekhawat, N. S., Hall, L. N., Sulewski, M. E., Woreta, F. A., Wang, J., Smith, K. M., & Kuo, I. C. (2023) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000993 · Cited by 18
BCLA CLEAR presbyopia: Management with intraocular lenses
Schnider, C. M., Yuen, L., Rampat, R., Zhu, D., Dhallu, S. K., Trinh, T., Gurnani, B., Abdelmaksoud, A. H., Bhogal-Bhamra, G. K., Wolffsohn, J. S., et al. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102253 · Cited by 18
“The use of monovision for the management of presbyopia using contact lenses has been utilised since the early 1960s and in refractive surgery since the mid-1990s [2,3].”
Shaker, L. M., Al‐Amiery, A. A., & Isahak, W. N. R. W. (2024) · International Journal of Low-Carbon Technologies · doi:10.1093/ijlct/ctad136 · Cited by 21
A clearer vision: a mini-review on contact lenses
Shaker, L. M., Al‐Amiery, A. A., & Al‐Azzawi, W. K. (2023) · Journal of Optics · doi:10.1007/s12596-023-01222-w · Cited by 17
“Daily disposable lenses are convenient, hygienic, and reduce the risk of eye infections [18].”
Zhu, Q., Wang, Y., Wang, L., & Su, G. (2024) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2024.124702 · Cited by 15
Topical review: Twenty‐five years of silicone hydrogel soft contact lenses
Walsh, K., Jones, L., Morgan, P. B., PAPAS, E. B., & Sulley, A. L. (2025) · Optometry and Vision Science · doi:10.1097/opx.0000000000002267 · Cited by 16
“69,70 Despite the importance of increasing corneal oxygenation during contact lens wear, there has not been a “Dk arms race” over the 25 years of SiHy product launches.”
Self-citationAffluence and Contact Lens Prescribing
Efron, N., & Morgan, P. B. (2022) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000933 · Cited by 14
Self-citationEfron, N., Morgan, P. B., Woods, C. A., JONES, D. A., Jones, L., & Nichols, J. J. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102310 · Cited by 14
Self-citationCoşkun, A., Savaş, İ. N., Can, O., & Lippi, G. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453152 · Cited by 16
“%) are females, with users in the age group of 15–24 representing the highest percentage (approximately 25%), and a decline observed with increasing or decreasing age [211].”
International trends in rigid contact lens prescribing (2000–2023): An update
Efron, N., Morgan, P. B., Woods, C. A., Jones, D., Jones, L., & Nichols, J. J. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102255 · Cited by 13
Self-citationColored contact lens with all-weather humidity-triggered discoloration
Dong, H., Jin, X., Zhang, S.-X., Xue, C. Q., Liu, M., & Luo, Y. (2023) · Dyes and Pigments · doi:10.1016/j.dyepig.2023.111483 · Cited by 10
Real-Time Ocular Comfort Reporting in Monthly Replacement Contact Lens Wearers
Call, T., Pucker, A. D., McGwin, G., Franklin, Q. X., & Logan, A. (2023) · Clinical Optometry · doi:10.2147/opto.s403319 · Cited by 10
Profile of contact lens prescribing in GCC countries
Noushad, B., Mohamed, Z. D., Vankudre, G. S., Hussaindeen, J. R., Rani, K., Elhaj, M., & Alshamli, N. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102128 · Cited by 9
Advances in Contact Lens Care Solutions: PVP-I Disinfectant and HAD Wetting Agents From Japan
Itokawa, T., Yamasaki, K., Suzuki, T., & Koh, S. (2023) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000001060 · Cited by 8
The clinical impact of contact lens wear on neural structure and function of the cornea
Chiang, J. C. B., Tajbakhsh, Z., & Wolffsohn, J. S. (2024) · Clinical and Experimental Optometry · doi:10.1080/08164622.2024.2401511 · Cited by 8
International trends in prescribing contact lenses for myopia control (2011–2024): An update
Efron, N., Morgan, P. B., Woods, C. A., JONES, D. A., Jones, L., Santodomingo‐Rubido, J., & Nichols, J. J. (2025) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2025.102451 · Cited by 8
Self-citationRichards, J., Rickert, M. E., Carr, K., Meyer, D., & Kollbaum, P. S. (2024) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13292 · Cited by 7
“Specifically, due to the changing contact lens market, 32 a significantly smaller proportion of the available data were hydrogel (16.1”
BackgroundInfluentialCurrent status of contact lenses usage in Korea: A population-based cohort study 2021
Kim, M. S., Paik, J., Kim, D., Hwang, H. S., Han, K., & Na, K. (2024) · PLoS ONE · doi:10.1371/journal.pone.0296279 · Cited by 7
“In addition, the distribution of refractive errors, the level of training of contact lens dispensers (optometrists, ECPs, or unregulated lens sellers), the age and sex ratio of the population, and the socioeconomic conditions of the patients affect the status of prescriptions for contact lenses [5].”
BackgroundResultInfluentialChang, L., Sun, C., Lee, T.-C., Wang, Y., & Liao, L.-L. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102283 · Cited by 9
Morgan, P. B., Efron, N., Woods, C. A., JONES, D. A., Jones, L., & Nichols, J. J. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102348 · Cited by 7
Self-citationImpact of contact lens correction on wavefront aberrations and vision quality in keratoconus
Swartz, G., Alam, K., Gentle, A., & Downie, L. E. (2025) · Ophthalmic and Physiological Optics · doi:10.1111/opo.70037 · Cited by 8
“56,57 It is estimated that 90% of individuals with keratoconus utilise rigid contact lenses for vision correction.”
Lim, C., García‐Montero, M., Courtis, A., Hainey, P., Madrid‐Costa, D., & Crooke, A. (2024) · Gels · doi:10.3390/gels10110726 · Cited by 6
Microbial keratitis in the age of resistance: unlocking the therapeutic potential of phage therapy
Ibrahim, R., Kumar, P. S., & Aranjani, J. M. (2025) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-025-06961-z · Cited by 6
“A global incidence based on epide - miological studies estimates that the incidence related to the use of a contact lens occurs in 2 to 20 per 10,000 users per year, making prevention and treatment a necessity [ 5].”
Assessing PCR-Positive Acanthamoeba Keratitis—A Retrospective Chart Review
Blaser, F., Bajka, A., Grimm, F., Metzler, S., Herrmann, D., Barthelmes, D., Zweifel, S. A., & Said, S. (2024) · Microorganisms · doi:10.3390/microorganisms12061214 · Cited by 6
“In Switzerland, as in most European countries, soft contact lenses are the most used [43].”
BackgroundPrescribing patterns of myopia control contact lenses among optometrists in Ireland
Moore, M., Flitcroft, I., & Loughman, J. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13096 · Cited by 6
Yamasaki, K., Dantam, J., Sasanuma, K., Hisamura, R., Mizuno, Y., Hui, A., & Jones, L. (2023) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2023.102104 · Cited by 5
Physical properties of soft contact lens multipurpose solutions commercially available in Ghana
Ilechie, A. A., Addo, N. A., Aidoo, E., Armah, A., Faheem, F., & Achimah, B. A. A. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e32491 · Cited by 5
“Contact lenses are gradually evolving into an extremely practical alternative to spectacles in Ghana and many parts of the world [1 – 3].”
BackgroundEfron, N., Morgan, P. B., Woods, C. A., JONES, D. A., Jones, L., & Nichols, J. J. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102276 · Cited by 5
Self-citationInternational trends in prescribing extended wear soft contact lenses (2000–2023): An update
Morgan, P. B., Efron, N., Woods, C. A., JONES, D. A., Jones, L., & Nichols, J. J. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102285 · Cited by 5
Self-citationLutmer, K. M., Wagner, H. E., Richdale, K., Zimmerman, A. B., Datta, A., & Dougherty, B. E. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13078 · Cited by 4
“35 Thus, previous reports may not reflect current wearing patterns.”
Walkden, A., Brahma, A., Chidambaram, J., Carley, F., & Przybek-Skrzypecka, J. (2023) · Clinical ophthalmology · doi:10.2147/opth.s438990 · Cited by 4
“…tide of shortsightedness worldwide, followed by the soaring number of contact-lens-wearers and finally a globally higher incidence of AK. 10,35,36 Given that AK is a cause of potential medical negligence due to late diagnosis resulting in low visual acuity, all allied healthcare professionals…”
BackgroundChiang, J. C. B., & Wolffsohn, J. S. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102340 · Cited by 5
Defining Daily Disposable Contact Lens Wear in a Clinical Study
Wagner, H. E., Zimmerman, A. B., Lam, D. Y., Kinoshita, B. T., ROSNER, B. A., Mitchell, G. L., & Richdale, K. (2023) · Optometry and Vision Science · doi:10.1097/opx.0000000000001985 · Cited by 4
Morgan, O. A., Mirza, A., Parmar, K. R., Plowright, A. J., Vega, J. A., Orsborn, G. N., Maldonado‐Codina, C., Whitehead, J. C., & Morgan, P. B. (2023) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2023.101887 · Cited by 4
“In recent work, Morgan and Efron [3] noted a much lower fitting rate for soft toric contact lenses in Czechia, Japan, Lithuania, Russia and Taiwan compared to many other markets.”
BackgroundSelf-citationOptical Material Recycling Practices: A Look at Portuguese Optical Centers
Oliveira, A. P., Martínez-Pérez, C., Barqueira, A., Alvarez-Peregrina, C. C., & Sánchez‐Tena, M. Á. (2024) · Sustainability · doi:10.3390/su16145931 · Cited by 4
Contact Lens Prescribing Patterns in Palestine
Beshtawi, I. M., Ghaboun, N., Titi, R. A., Asia, H., Abu-Khalaf, N., & Frehat, R. (2025) · Palestinian medical and pharmaceutical journal/Palestinian medical & pharmaceutical journal · doi:10.59049/2790-0231.11.4.2549 · Cited by 3
Mojarrad, N. G., Rountree, L., Terry, L., Bruce, H., Hallam, E., Jolly, L., Retallic, N., & Evans, K. (2023) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000001031 · Cited by 3
“31 However, the average age of contact lens wearers globally is 31 years old, 3 which is within our inclusion criteria and within one SD of mean age.”
BackgroundShin, S.-M., Park, H.-I., & Sung, A.-Y. (2023) · Micromachines · doi:10.3390/mi14101883 · Cited by 3
“Silicone hydrogel material has high oxygen permeability and is currently widely used in contact lenses [3].”
BackgroundBlanc, E., Faran, S. A., Dufresne, A., Fitzhenry, L., & Mariano, M. (2024) · Journal of Applied Polymer Science · doi:10.1002/app.56324 · Cited by 3
Yang, X.-D., Lyu, Y., & Wan, G. (2024) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-024-06637-0 · Cited by 2
The Impact of Comfort Eluting Agents and Replacement Frequency on Enhancing Contact Lens Performance
Phan, C., Hui, A., Shi, X. C., Zheng, Y., Subbaraman, L. N., Wu, J. Y., & Jones, L. (2025) · Clinical ophthalmology · doi:10.2147/opth.s512246 · Cited by 2
“This is reflected in the increasing popularity of daily disposable CLs over the past decade, 128,131–134 , 142 which accounted for Among the reusable CL modality, the monthly replacement schedule has emerged as the dominant choice worldwide, significantly surpassing the popularity of the 2-week…”
InfluentialPrevalence and Risk Factors of Dry Eye Syndrome in University Students
Kim, J.-M. (2023) · The Korean Journal of Vision Science · doi:10.17337/jmbi.2023.25.4.465 · Cited by 2
What choices of visual correction do people make for recreational running?
Latham, K., Dunn, G., Morrison, A., & Timmis, M. A. (2024) · PLoS ONE · doi:10.1371/journal.pone.0305102 · Cited by 2
“Bivariate analyses also suggested that women and younger people were more likely to use contact lenses, in keeping with other studies [22].”
ResultOcular thermography for optometric practice – a third reincarnation?
Efron, N. (2024) · Clinical and Experimental Optometry · doi:10.1080/08164622.2024.2431090 · Cited by 2
“Numerous types of contact lenses are prescribed today, 13,14 which are known to induce subtle changes to the cornea, 15,16 conjunctiva 17 and eyelids.”
Self-citationSeo, J. (2023) · Optician · doi:10.12968/opti.2023.268.6927.27 · Cited by 1
Schulze, M., & Janssen, M. (2023) · Optician · doi:10.12968/opti.2023.268.6910.26 · Cited by 1
Celebrating 30 years of an ongoing annual international contact lens prescribing survey (1996–2025)
Morgan, P. B., & Efron, N. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102355 · Cited by 1
Self-citationEnhancement of the wettability of rigid gas permeable contact lenses by low-pressure plasma
Zanosko, A. I., Васильев, Д. Д., & Nazarenko, M. V. (2025) · Biomedical Engineering · doi:10.1007/s10527-025-10445-z · Cited by 1
“The International Contact Lens Institute has reported that more than 140mio. people worldwide now use contact lenses, with about 10% of them choosing rigid gas permeable lenses (RGPL) [2].”
Ratnayake, D., Ansah, M., Batham, B., Keddie, D. J., McNee, G. S., & Heaselgrave, W. (2025) · Microorganisms · doi:10.3390/microorganisms13030665 · Cited by 1
“Global contact lens use is rising, with approximately 4.5 million wearers in the UK and over 41 million in the USA [1,2].”
InfluentialCharacterization of the Pre-lens Tear Film in Hydrogel and Silicone Hydrogel Contact Lens Wear
Novo‐Diez, A., Nieto, L. V., Pérez-Charro, S., la Rosa, A. L., López‐Miguel, A., & González-García, M. J. (2025) · Journal of Ophthalmic and Vision Research · doi:10.18502/jovr.v20.16812 · Cited by 1
“[1, 2] Given that hydrogel and silicone hydrogel CLs are the most commonly fitted CLs, [23–25] this study aimed to evaluate the pre-lens tear film changes in the ocular surface induced by CL wear, comparing a hydrogel CL (omafilcon A) and a silicone hydrogel CL (stenfilcon A).”
Impact of user-generated YouTube videos on knowledge and beliefs in contact lens wearers
Yeo, S., Samuels, A., Keay, L. J., Faasse, K., & Carnt, N. A. (2025) · Clinical and Experimental Optometry · doi:10.1080/08164622.2025.2589386 · Cited by 2
“…It is likely that case hygiene is less emphasised by eye care practitioners due to increasing prescribing trends in daily disposable contact lenses, 26 however it is important to note that prescribing trends and usage trends are not the same, and that at least 50% of wearers use reusable contact…”
Balasubramani, K., Arthanari, S., Subramanian, M., & Mohan, P. (2025) · Next Nanotechnology · doi:10.1016/j.nxnano.2025.100321 · Cited by 1
Read, M., Morgan, P. B., Maldonado‐Codina, C., Orsborn, G. N., Vega, J. G. (., & Navascues‐Cornago, M. (2025) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2025.102604 · Cited by 1
Self-citationParimi, V., Elsner, A. E., Clark, C., & King, B. J. (2026) · PLoS ONE · doi:10.1371/journal.pone.0352879 · Cited by 1
Fogt, J. S., Satiani, N., & Patton, K. (2023) · Journal of Contact lens Research and Science · doi:10.22374/jclrs.v7i1.54 · Cited by 1
Biocompatible Coatings for Medical Applications
Mallick, R., Saha, S., Datta, D., Pal, S., & Roy, S. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/9781837675555-00446 · Cited by 1
Toshida, H., Matsuzawa, A., Koh, S., & Hori, Y. (2024) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000001147 · Cited by 1
Thirtieth anniversary of daily disposable contact lenses
Efron, N. (2024) · Clinical and Experimental Optometry · doi:10.1080/08164622.2024.2304041 · Cited by 1
Self-citationAll soft contact lenses should be silicone hydrogel daily disposables
Efron, N. (2024) · Clinical and Experimental Optometry · doi:10.1080/08164622.2024.2416454 · Cited by 1
Self-citationLadopoulos, K., Pateras, E., & Ninos, G. (2026) · Cureus · doi:10.7759/cureus.104008
“The benefits of FFLs are the most pronounced in high myopia and hyperopia [57,58].”
Foreword – Why specialist lenses?
Harrop, K., Beerten, R., Steenbekkers, G., Voltz, K., Johnson, L., & Siergey, J. (2022) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2022.101797
Self-Assessment of Soft Contact Lens Wear and Care among University Students
Choi, J.-S., & Kim, J.-M. (2023) · The Korean Journal of Vision Science · doi:10.17337/jmbi.2023.25.4.347
Long-term evolution of signs and symptoms in contact lens wearers
Nieto, L. V., la Rosa, A. L., López‐Miguel, A., & González-García, M. J. (2024) · Ciencia y Tecnología para la Salud Visual y Ocular · doi:10.19052/svo.21.iss2.1400
Research impact of various optometric sub-fields
Efron, N. (2024) · Clinical and Experimental Optometry · doi:10.1080/08164622.2024.2341836
Self-citationExperimental Study on Ocular Surface Protection by Soft Contact Lenses Due to Volcanic Ash Exposure
Toshida, H., Matsuzaki, Y., & Miyazaki, M. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13175281
Top ten golden rules for carving out a successful career in academic research
Efron, N. (2024) · Clinical and Experimental Optometry · doi:10.1080/08164622.2024.2410881
Self-citationCPD: Strategies to increase success with new soft CL wearers
Samuels, A., Morgan, P. B., & Sulley, A. L. (2023) · Optician · doi:10.12968/opti.2023.268.6910.20
Self-citation2024 Charles F. Prentice Medal award lecture: Moments of inspiration
Efron, N. (2024) · Optometry and Vision Science · doi:10.1097/opx.0000000000002202
Self-citationQuarter of a century of contact lens prescribing trends in Australia (2000–2024)
Efron, N., Woods, C. A., & Morgan, P. B. (2025) · Clinical and Experimental Optometry · doi:10.1080/08164622.2025.2451346
“Custom-made rigid lenses, such as scleral, semi-scleral 6 and orthokeratology designs, 7 tend to be relatively expensive, thus creating a financial disincentive for patients to regularly replace their lenses.”
InfluentialSelf-citationProfessor Eric Papas: leading exponent of contact lens research and development
Efron, N. (2025) · Clinical and Experimental Optometry · doi:10.1080/08164622.2025.2453046
Self-citationGoal framing of health promotion messages in contact lens wear
Wagner, H. E., Lam, D. Y., & Nguyen, A. L. (2025) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2025.102387
Contact lens discomfort characterization
Nieto, L. V. (2025) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/75849
Contact Lenses: Current Designs and New Strategies
Carnt, N. A., Samuels, A., Yeo, S. L. S., & Stapleton, F. J. (2025) · Royal Society of Chemistry eBooks · doi:10.1039/9781839169779-00013
Refitting Previous Presbyopic Contact Lens Dropouts with a Single Use Multifocal Contact Lens
Fogt, J. S., Roth, M., Travis, B. A., Bickle, K. M., & Gardner, H. P. (2025) · Clinical Optometry · doi:10.2147/opto.s526434
“5,18,19 Reluctance to introduce multifocal lenses can stem from difficulty predicting which patients will be successful, concerns over required chair time, and fear that the fitting is unlikely to succeed.”
Yakar, K. (2025) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2025.104780
Dhallu, S. K. (2025) · Optician · doi:10.12968/opti.2025.272.7016.20
Hilliam, Y., Armstrong, S. D., Langendonk, R. F., Kaye, S. B., & Winstanley, C. (2025) · Journal of Medical Microbiology · doi:10.1099/jmm.0.002073
“Global increases in myopia and industrialization have led to corresponding increases in the use of vision-correcting contact lenses (CLs) [6].”
Ensure your paper gets published: ten tips for responding effectively to reviewer comments
Efron, N. (2025) · Clinical and Experimental Optometry · doi:10.1080/08164622.2025.2589401
Self-citationBanik, A., & Goyal, A. (2025) · Clinical and Experimental Optometry · doi:10.1080/08164622.2025.2596938
Konovchuk, T. V., Onishchenko, O. N., & Nikolaeva, U. M. (2025) · The EYE GLAZ · doi:10.33791/2222-4408-2025-4-361-366
Alzghoul, E. A. (2024) · UNSWorks (UNSW Sydney) · doi:10.26190/unsworks/30611
Corneal sensitivity in new silicone hydrogel contact lens wearers
Seghetti, M., Nosch, D. S., & Albon, J. (2025) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2026.102607
“[80] A non-CL wearer control group would have additionally strengthened the power of this study, by recording corneal sensitivity longitudinally in non-wearers in parallel, to confirm that the changes in corneal sensitivity were due to CL wear and no other environmental factors.”
Contact lens procurement practices and wear habits among users in Oman
Al-Ghaithi, M. D., Al-Esaei, M. M., Al-Qasmi, M. K., Al-Buraiki, K. S., & Noushad, B. (2026) · Medical Hypothesis Discovery & Innovation in Optometry · doi:10.51329/mehdioptometry235
“Global estimates suggest that millions of individuals opts for contact lenses, with the highest uptake among young adults, particularly females [2, 3].”
Efron, N. (2026) · Clinical and Experimental Optometry · doi:10.1080/08164622.2026.2622570
Self-citationTrends in the Management of Keratoconus in Australia
Kha, R., Kandel, H., & Watson, S. L. (2026) · Ophthalmic and Physiological Optics · doi:10.1007/s44402-026-00096-2
Beshtawi, I. M., & Aljarousha, M. (2026) · Cureus · doi:10.7759/cureus.110288
Perschak, P., Said, S., Metzler, S., Zweifel, S. A., Barthelmes, D., Hermann, D., Herrmann, D., Hafezi, F., Kollros, L., Bosch, M. M., et al. (2026) · Journal of Optometry · doi:10.1016/j.optom.2026.100622
“Reusable SCL wearers applied their CLs for a median (IQR [range]) time of 14 (12 - 15 [4 - 24]) hours, RCL users for 13.5 (11.25 - 15 [6 - 18]) hours, and the ScCL subgroup for 13.5 (9 - 15 [6 - 22]) hours.”
InfluentialFriction: the effect on the ocular surface
Sheludchenko, N. V., Sé, A., Vasileva, A. P., Yusef, S. N., Шелудченко, В. М., & Makarova, M. A. (2026) · Russian Annals of Ophthalmology · doi:10.17116/oftalma202614203156
Extended contact lens wear: will we ever break through the ten percent glass ceiling?
Efron, N. (2026) · Clinical and Experimental Optometry · doi:10.1080/08164622.2026.2699201
“2”
Self-citationHalf a century of refractive surgery – where are we now?
Efron, N. (2026) · Clinical and Experimental Optometry · doi:10.1080/08164622.2026.2699206
Self-citationChallenging conventional wisdom
Efron, N. (2026) · Clinical and Experimental Optometry · doi:10.1080/08164622.2026.2703788
Self-citationSoft contact lens wear in children: benefits and limitations
Greenaway, N. L., Sulley, A. L., & Young, G. (2026) · Clinical and Experimental Optometry · doi:10.1080/08164622.2026.2694435
Metadata
- Authors
- Morgan, P. B., & Efron, N.
- Affiliations
- University of Manchester (GB)
- Queensland University of Technology (AU)
- Corresponding author
- Efron, Nathan
- Venue
- Clinical and Experimental Optometry
- Publisher
- Informa UK Limited
- Published
- 2022-02-20
- Volume
- 105
- Issue
- 3
- Pages
- 298-312
- ISSN
- 0816-4622 (ISSN-L)
- 1444-0938
- OpenAlex
- W4213344330
- Cited by
- 102
- References
- 35
- Citations by year
- 2026: 16 · 2025: 25 · 2024: 34 · 2023: 22 · 2022: 5
- FWCI
- 19.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical and Experimental Optometry (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Ocular Infections and Treatments
- Keywords
- contact lens prescribing, contact lens fitting, global trends, silicone hydrogel contact lenses, daily disposable lenses, multifocal lenses, presbyopia, extended wear
- MeSH terms
- Adolescent, Adult, Contact Lenses, Contact Lenses, Hydrophilic, Female, Humans, Male, Optometry, Surveys and Questionnaires, Silicones, Prescriptions, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.