Two-dimensional detector software: From real detector to idealised image or two-theta scan
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Detector systems introduce distortions into acquired data. To obtain accurate angle and intensity information, it is necessary to calibrate, and apply corrections. Intensity non-linearity, spatial distortion, and non-uniformity of intensity response, are the primary considerations. It is better to account for the distortions within scientific analysis software, but often it is more practical to correct the distortions to produce ‘idealised’ data. Calibration methods and software have been developed for single crystal diffraction experiments, using both approaches. For powder diffraction experiments the additional task of converting a two-dimensional image to a one-dimensional spectrum is used to allow Rietveld analysis. This task may be combined with distortion correction to produce intensity information and error estimates. High-pressure experiments can introduce additional complications and place new demands on software. Flexibility is needed to be able to integrate different angular regions separately, and to produce profiles as a function of angle of azimuth. Methods to cope with awkward data are described, and examples of the techniques applied to data from high pressure experiments are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Dollase, W. A. (1986) · Journal of Applied Crystallography · doi:10.1107/s0021889886089458 · Cited by 1,690
Evaluation of single-crystal X-ray diffraction data from a position-sensitive detector
Kabsch, W. (1988) · Journal of Applied Crystallography · doi:10.1107/s0021889888007903 · Cited by 1,505
Calibration and correction of spatial distortions in 2D detector systems
Hammersley, A. P., Svensson, S. O., & Thompson, A. (1994) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(94)90720-x · Cited by 413
Self-citationMesserschmidt, A., & Pflugrath, J. W. (1987) · Journal of Applied Crystallography · doi:10.1107/s002188988708662x · Cited by 391
Cited by
DIOPTAS: a program for reduction of two-dimensional X-ray diffraction data and data exploration
Prescher, C., & Prakapenka, V. B. (2015) · High Pressure Research · doi:10.1080/08957959.2015.1059835 · Cited by 1,981
Juhás, P., Davis, T., Farrow, C. L., & Billinge, S. J. L. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889813005190 · Cited by 1,341
Nanostructured high-energy cathode materials for advanced lithium batteries
Sun, Y.-K., Chen, Z., Noh, H.-J., Lee, D.-J., Jung, H.-G., Ren, Y., Wang, S., Yoon, C. S., Myung, S.-T., & Amine, K. (2012) · Nature Materials · doi:10.1038/nmat3435 · Cited by 1,093
CsV3Sb5 : A Z2 Topological Kagome Metal with a Superconducting Ground State
Ortiz, B. R., Teicher, S. M. L., Hu, Y., Zuo, J. L., Sarte, P. M., Schueller, E. C., Abeykoon, A. M. M., Krogstad, M. J., Rosenkranz, S., Osborn, R., et al. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.247002 · Cited by 970
Electrolyte design for Li-ion batteries under extreme operating conditions
Xu, J., Zhang, J., Pollard, T. P., Li, Q., Tan, S., Hou, S., Wan, H., Chen, F., He, H., Hu, E., et al. (2023) · Nature · doi:10.1038/s41586-022-05627-8 · Cited by 970
Metadata
- Authors
- Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D.
- Venue
- High Pressure Research
- Publisher
- Informa UK Limited
- Published
- 1996-01
- Volume
- 14
- Issue
- 4-6
- Pages
- 235-248
- ISSN
- 0895-7959 (ISSN-L)
- 1477-2299
- OpenAlex
- W1983874564
- Cited by
- 4,674
- References
- 5
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.