CoChat

Inhalation of Ultrafine and Fine Particulate Matter Disrupts Systemic Vascular Function

Rundell, Kenneth W., Hoffman, Jay R., Caviston, Renee, Bulbulian, Ronald, Hollenbach, Amanda M. · 2007 · Inhalation Toxicology
Cited by 150

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

This study investigated the effects of particulate matter (PM) with aerodynamic diameter 0.02-1 microm (noted as PM1) inhalation during exercise on conduit artery and microvascular function. Inhalation of internal combustion-derived PM is associated with cardiovascular mortality and morbidity. Direct action of PM on the vascular endothelium is likely, as a substantial fraction of ultrafine PM translocates from the alveoli to the circulatory system. Sixteen intercollegiate athletes performed 30 min of exercise while inhaling low or high PM1. Flow-mediated brachial artery dilation (FMD) using high-resolution ultrasonography with simultaneous measurements of forearm oxygen kinetics using near infrared spectrophotometry (NIRS) was done before and after exercise. Basal brachial artery vasoconstriction was found after high PM1 exercise (4.0%, 4.66 +/- 0.609 to 4.47 +/- 0.625 mm diameter; p = .0002), but not after low PM1 exercise (-0.3%, 4.66 +/- 0.626 to 4.68 +/- 0.613 mm diameter). FMD was impaired after high PM1 exercise (6.8 +/- 3.58% for preexercise FMD and 0.30 +/- 2.74% for postexercise FMD, p = .0001), but not after low PM1 exercise (6.6 +/- 4.04% for preexercise FMD and 4.89 +/- 4.42% for postexercise FMD). Reduction in forearm muscle reperfusion estimated by reoxygenation slope-to-baseline after 4 min cuff ischemia was observed for high PM1 exercise (55% vs. 3%, p = .0006); no difference was noted for low PM1 exercise. Brachial artery FMD was significantly correlated to muscle reoxygenation slope-to-baseline (r = .50, p = .005). Acute inhalation of high [PM1] typical of urban environments impairs both systemic conduit artery function and microcirculation. The observed decrease reoxygenation slope-to-baseline after cuff release is consistent with reduced blood flow in the muscle microvasculature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/08958370601051727

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 150

Metadata

Authors
Rundell, K. W., Hoffman, J. R., Caviston, R., Bulbulian, R., & Hollenbach, A. M.
Venue
Inhalation Toxicology
Published
2007-01
Volume
19
Issue
2
Pages
133-140
ISSN
  • 0895-8378 (ISSN-L)
  • 1091-7691
OpenAlex
W1985535395
Cited by
150
References
7
FWCI
5.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inhalation of Ultrafine and Fine Particulate Matter Disrupts Systemic Vascular Function. https://app.cochat.ai/papers/10.1080/08958370601051727
The paper
Rundell, K. W., Hoffman, J. R., Caviston, R., Bulbulian, R., & Hollenbach, A. M. (2007). Inhalation of Ultrafine and Fine Particulate Matter Disrupts Systemic Vascular Function. Inhalation Toxicology. https://doi.org/10.1080/08958370601051727

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.