Abstract
Metastable β Ti alloys are widely projected for manufacturing the next generation of biomedical implants. The primary applications of these materials are envisaged in orthopedic, cardiovascular, and orthodontic biomedical devices. Development of an alloyprogresses through stages of compositional design, thermo-mechanical processing, and evaluation of material performance. This review tracks the progress at these three stages of alloy development particularly for use in orthopedic devices. The strategies to design low modulus compositions of β Ti alloys are critically reviewed. This is followed by the processing routes employed to achieve high strength to modulus ratio suitable for orthopedic applications. The effect of processing on performance metrics of these alloys vis-à-vis fatigue resistance, tribological response, corrosion behaviour, and biocompatibility are reviewed. In the end, targeted research areas for the future are highlighted along with encouraging strategies, with the aim to ensue clinical application of β Ti alloys.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
Titanium alloys in total joint replacement—a materials science perspective
Long, M., & Rack, H. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00146-4 · Cited by 3,510 · cited 1×
“Furthermore, β Ti alloys have a lower modulus than current metallic biomaterials Ti – 6Al – 4V (110 GPa), 316L stainless steel (200 GPa), and Co – Cr – Mo alloys (200 – 230 GPa) [21].”
BackgroundThe metallurgy and processing science of metal additive manufacturing
Sames, W. J., List, F. A., Pannala, S., Dehoff, R. R., & Babu, S. S. (2016) · International Materials Reviews · doi:10.1080/09506608.2015.1116649 · Cited by 2,529 · cited 1×
“[127] SLM using mixture of elemental powders manufacturing [137,138].”
MethodChen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398 · cited 3×
“Implants corrode in the body despite high corrosion resistance due to high salinity, low oxygen, presence of biomolecules, low pH during in fl ammation in body environment, and damage to the protective oxide fi lm by fretting or wear [7,8].”
BackgroundTreatment of Infections Associated with Surgical Implants
Darouiche, R. O. (2004) · New England Journal of Medicine · doi:10.1056/nejmra035415 · Cited by 2,257 · cited 1×
“The rate of implant failure by bacterial infection is reported to be between 0.5% and 5.0% [26 – 28].”
BackgroundInfluentialMetal Additive Manufacturing: A Review of Mechanical Properties
Lewandowski, J. J., & Seifi, M. (2016) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070115-032024 · Cited by 1,722 · cited 1×
“[127] SLM using mixture of elemental powders manufacturing [137,138].”
MethodDevelopment of new metallic alloys for biomedical applications
Niinomi, M., Nakai, M., & Hieda, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.037 · Cited by 1,623 · cited 1×
“[7,34,35].”
Design and mechanical properties of new β type titanium alloys for implant materials
Kuroda, D., Niinomi, M., Morinaga, M., Kato, Y., & Yashiro, T. (1998) · Materials Science and Engineering A · doi:10.1016/s0921-5093(97)00808-3 · Cited by 1,323 · cited 1×
“One of the early compositions to be designed using this approach was Ti – 29Nb – 13Ta – 4.6 Zr with an elastic modulus close to 50 GPa [42].”
MethodInfluentialPhase-field models in materials science
Steinbach, I. (2009) · Modelling and Simulation in Materials Science and Engineering · doi:10.1088/0965-0393/17/7/073001 · Cited by 1,310
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Biological factors contributing to failures of osseointegrated oral implants, (II). Etiopathogenesis
Esposito, M., Hirsch, J., Lekholm, U., & Thomsen, P. (1998) · European Journal of Oral Sciences · doi:10.1046/j.0909-8836..t01-6-.x · Cited by 1,176 · cited 1×
“Aside from biomaterial properties, endogenous factors that a ff ect osseointegration include age, general health, bone quality, and anatomical location [32].”
BackgroundThe significance of infection related to orthopedic devices and issues of antibiotic resistance
Campoccia, D., Montanaro, L., & Arciola, C. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.044 · Cited by 1,109
An introduction to phase-field modeling of microstructure evolution
Moelans, N., Blanpain, B., & Wollants, P. (2008) · Calphad · doi:10.1016/j.calphad.2007.11.003 · Cited by 1,006
Corrosion of Metal Orthopaedic Implants*
Jacobs, J. J., Gilbert, J. L., & Urban, R. M. (1998) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199802000-00015 · Cited by 967
Ribeiro, M., Monteiro, F. J., & Ferraz, M. P. (2012) · Biomatter · doi:10.4161/biom.22905 · Cited by 824 · cited 1×
“Surgical procedures, host factors, anatomical sites, and biomaterial properties can a ff ect the bacterial response [25 – 27].”
BackgroundBiomaterial strategies for engineering implants for enhanced osseointegration and bone repair
Agarwal, R., & García, A. J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.013 · Cited by 789 · cited 1×
“A good osseointegration ensures implant stability and longevity [29 – 31].”
BackgroundThe future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779 · cited 1×
“Surgical procedures, host factors, anatomical sites, and biomaterial properties can a ff ect the bacterial response [25 – 27].”
BackgroundA new look at biomedical Ti-based shape memory alloys
Biesiekierski, A., Wang, J., Gepreel, M. A.-H., & Wen, C. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.01.018 · Cited by 719 · cited 1×
“Comprehensive reviews on biomedical functional β Ti alloys by Miyazaki and co-workers [1,2] and Wen and co-workers [3] can be found in literature.”
BackgroundManufacture by selective laser melting and mechanical behavior of a biomedical Ti–24Nb–4Zr–8Sn alloy
Zhang, L., Klemm, D., Eckert, J., Hao, Y., & Sercombe, T. B. (2011) · Scripta Materialia · doi:10.1016/j.scriptamat.2011.03.024 · Cited by 597 · cited 6×
“The strength along other direction of the AM material was not reported for detailed comparison with wrought alloy [125].”
BackgroundMethodInfluentialFatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti–29Nb–13Ta–4.6Zr
Niinomi, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00069-3 · Cited by 549 · cited 1×
“Ti – 29Nb – 13Ta – 4.6Zr is the most comprehensively investigated alloy for its fatigue properties [99,142 – 147].”
BackgroundMetal ion release from metal implants
Hanawa, T. (2004) · Materials Science and Engineering: C · doi:10.1016/j.msec.2004.08.018 · Cited by 528 · cited 1×
“Implants corrode in the body despite high corrosion resistance due to high salinity, low oxygen, presence of biomolecules, low pH during in fl ammation in body environment, and damage to the protective oxide fi lm by fretting or wear [7,8].”
BackgroundBiologic effects of implant debris.
Hallab, N. J., & Jacobs, J. J. (2009) · PubMed · Cited by 422
Sing, S. L., Yeong, W. Y., & Wiria, F. E. (2015) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2015.11.141 · Cited by 414 · cited 4×
“In contrast, the unmelted particles after AM in case of powder mixtures are powders of elements with high melting point such as Nb and Ta [127,130,135,136].”
BackgroundMethodInfluentialFirst-principles calculations for development of low elastic modulus Ti alloys
Ikehata, H., Nagasako, N., Furuta, T., Fukumoto, A., Miwa, K., & Saito, T. (2004) · Physical Review B · doi:10.1103/physrevb.70.174113 · Cited by 413
Sabban, R., Bahl, S., Chatterjee, K., & Suwas, S. (2018) · Acta Materialia · doi:10.1016/j.actamat.2018.09.064 · Cited by 398 · cited 1×
“These non-equilibrium microstructures, for example, ultra fi ne microstructures or high dislocation densities, can yield superior mechanical properties that are otherwise challenging to achieve [123,124].”
BackgroundSelf-citationWear particles, periprosthetic osteolysis and the immune system
Goodman, S. B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.035 · Cited by 340 · cited 1×
“The human body identi fi es wear debris as foreign objects thereby initiating an in fl ammatory response eventually leading to osteolysis [11,12].”
BackgroundAdvances in metals and alloys for joint replacement
Kunčická, L., Kocich, R., & Lowe, T. C. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.04.002 · Cited by 329 · cited 2×
“New compositions of β Ti alloys are composed of non-toxic elements such as Nb, Ta, Mo, Fe, Sn, and Zr, among others [33,34].”
BackgroundFischer, M., Joguet, D., Robin, G., Peltier, L., & Laheurte, P. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.02.033 · Cited by 295 · cited 4×
“In contrast, the unmelted particles after AM in case of powder mixtures are powders of elements with high melting point such as Nb and Ta [127,130,135,136].”
BackgroundMethodInfluentialBahl, S., Mishra, S., Yazar, K. U., Kola, I. R., Chatterjee, K., & Suwas, S. (2019) · Additive manufacturing · doi:10.1016/j.addma.2019.04.016 · Cited by 274 · cited 1×
“These non-equilibrium microstructures, for example, ultra fi ne microstructures or high dislocation densities, can yield superior mechanical properties that are otherwise challenging to achieve [123,124].”
BackgroundSelf-citationDevelopment of Ti–Nb–Zr alloys with high elastic admissible strain for temporary orthopedic devices
Ozan, S., Lin, J., Li, Y., İpek, R., & Wen, C. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.03.023 · Cited by 257 · cited 1×
“A combination of e/a with Bo – Md and Molyb-denum (Mo) equivalence is often used to design β Ti alloys [58 – 60].”
MethodSuper-elastic titanium alloy with unstable plastic deformation
Hao, Y., Li, S. J., Sun, S. Y., Zheng, C., Hu, Q., & Yang, R. (2005) · Applied Physics Letters · doi:10.1063/1.2037192 · Cited by 237 · cited 3×
“The incipient elastic modulus of Ti – 24Nb – 4Zr – 8Sn was reported to be 42 GPa that stabilised to 33 GPa after a few loading cycles [56].”
BackgroundMethodInfluentialBone and metal: An orthopaedic perspective on osseointegration of metals
Goriainov, V., Cook, R., M. Latham, J., G. Dunlop, D., & Oreffo, R. O. C. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.004 · Cited by 223 · cited 2×
“A good osseointegration ensures implant stability and longevity [29 – 31].”
BackgroundUnalloyed titanium for implants in bone surgery
Pohler, O. E. M. (2000) · Injury · doi:10.1016/s0020-1383(00)80016-9 · Cited by 214 · cited 1×
“Orthopedic implants experience cyclic loading during their service life, which is noted to cause failure [19,20,139].”
BackgroundBai, Y., Deng, Y., Zheng, Y., Li, Y., Zhang, R., Lv, Y., Zhao, Q., & Wei, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.062 · Cited by 209 · cited 2×
“The corrosion medium also has a signi fi cant impact on the corrosion rate of the alloys [155].”
BackgroundResultDeformation physics of shape memory alloys – Fundamentals at atomistic frontier
Chowdhury, P. B., & Şehitoğlu, H. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.03.003 · Cited by 194 · cited 1×
“Nonetheless, such a framework also has the potential to go beyond elastic modulus and even predict the strength of β Ti alloys [74,75].”
BackgroundWang, Q., Han, C., Choma, T., Wei, Q., Yan, C., Song, B., & Shi, Y. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.04.026 · Cited by 194
HUBER, M., REINISCH, G., TRETTENHAHN, G., ZWEYMULLER, K., & LINTNER, F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.07.032 · Cited by 180 · cited 3×
“The human body identi fi es wear debris as foreign objects thereby initiating an in fl ammatory response eventually leading to osteolysis [11,12].”
BackgroundTribo-electrochemical characterization of metallic biomaterials for total joint replacement
Diomidis, N., Mischler, S., More, N. S., & Roy, M. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.034 · Cited by 161
A revisit to atomistic rationale for slip in shape memory alloys
Chowdhury, P. B., & Şehitoğlu, H. (2016) · Progress in Materials Science · doi:10.1016/j.pmatsci.2016.10.002 · Cited by 160 · cited 1×
“Nonetheless, such a framework also has the potential to go beyond elastic modulus and even predict the strength of β Ti alloys [74,75].”
BackgroundBiocompatibility of new Ti–Nb–Ta base alloys
Hussein, A., Gepreel, M. A.-H., Gouda, M. K., Hefnawy, A., & Kandil, S. H. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.12.071 · Cited by 151 · cited 1×
“The corrosion resistance of β Ti alloys may be better [157,158], similar [76,159], or worse [57,160] than cp-Ti or Ti – 6Al – 4V.”
BackgroundKarre, R., Niranjan, M. K., & Dey, S. R. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.01.061 · Cited by 145 · cited 2×
“The ideal composition which possesses the lowest possible modulus in the ternary Ti – Nb – Zr system, was proposed based on the fi rst principles calculations [69].”
BackgroundMethodMartensitic Transformation and Superelastic Properties of Ti-Nb Base Alloys
Kim, H. Y., & Miyazaki, S. (2015) · MATERIALS TRANSACTIONS · doi:10.2320/matertrans.m2014454 · Cited by 144
Ruiz, A. J. O., Fernández, E., Vicente, A., Calvo, J. L., & Ortíz, M. C. (2011) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2011.02.021 · Cited by 144
Microstructure and mechanical properties of cold-rolled TiNbTaZr biomedical β titanium alloy
Wang, L., Lü, W., Qin, J., Zhang, F., & Zhang, D. (2008) · Materials Science and Engineering A · doi:10.1016/j.msea.2008.03.003 · Cited by 134 · cited 2×
“Several investigations have reported a decrease in elastic modulus after cold rolling [85 – 88].”
BackgroundChen, W., Chen, C., Zi, X., Cheng, X., Zhang, X., Lin, Y. C., & Zhou, K. (2018) · Materials Science and Engineering A · doi:10.1016/j.msea.2018.04.087 · Cited by 133
Yılmazer, H., Niinomi, M., Nakai, M., Cho, K., Hieda, J., Todaka, Y., & Miyazaki, T. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.01.056 · Cited by 126
Mechanical Properties of a Newly Additive Manufactured Implant Material Based on Ti-42Nb
Schulze, C., Weinmann, M., Schweigel, C., Keßler, O., & Bader, R. (2018) · Materials · doi:10.3390/ma11010124 · Cited by 120 · cited 2×
“Both pre-alloyed powders prepared by gas atomisation [125,126,129,131 – 134] or mixture of elemental powders [127,128,130,135,136] have been used in AM of β -Ti alloys.”
MethodSelective Laser Melting of Ti-45Nb Alloy
Schwab, H., Prashanth, K. G., Löber, L., Kühn, U., & Eckert, J. (2015) · Metals · doi:10.3390/met5020686 · Cited by 113
Bone formation at the surface of low modulus Ti–7.5Mo implants in rabbit femur
Lin, D., Chuang, C.-C., Lin, J. C., Lee, J.-W., Ju, C. P., & Yin, H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.005 · Cited by 113
Increasing strength of a biomedical Ti-Nb-Ta-Zr alloy by alloying with Fe, Si and O
Stráský, J., Harcuba, P., Bartha∥, K., Fekete, K., Landa, M., Srba, O., & Janeček, M. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.03.026 · Cited by 112 · cited 3×
“Several studies have neglected the contribution of O to e/a [57,63], whereas it has been considered in other reports [64].”
BackgroundMethodResultJiang, Y., Jia, T., Wooley, P. H., & Yang, S. (2013) · PubMed · Cited by 107
Nakai, M., Niinomi, M., & Oneda, T. (2011) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-011-0860-3 · Cited by 101 · cited 10×
“More importantly, higher strength without a signi fi cant increase in modulus can be achieved by fi ne tuning the deformation process and the aging treatment as demonstrated in [99].”
BackgroundMethodInfluentialAfonso, C. R. M., Ferrandini, P. L., Ramirez, A. J., & Caram, R. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.010 · Cited by 97 · cited 2×
“Afonso et al. reported phase separation of β phase on aging Ti – 35Nb – 7Zr – 5Ta alloy at 400°C [80].”
BackgroundNew Ti-Ta-Zr-Nb alloys with ultrahigh strength for potential orthopedic implant applications
Ozan, S., Lin, J., Li, Y., & Wen, C. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.07.011 · Cited by 96
Xie, K. Y., Wang, Y., Zhao, Y., Chang, L., Wang, G., Chen, Z., Cao, Y., Liao, X., Lavernia, E. J., Valiev, R. Z., et al. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.04.044 · Cited by 93
Panigrahi, A., Sułkowski, B., Waitz, T., Özaltın, K., Chromiński, W., Pukenas, A., Horky, J., Lewandowska, M., Skrotzki, W., & Zehetbauer, M. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.04.042 · Cited by 92
Investigations into Ti–(Nb,Ta)–Fe alloys for biomedical applications
Biesiekierski, A., Lin, J., Li, Y., et al. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.12.010 · Cited by 83 · cited 1×
“The presence of a stable thin TiO 2 layer on the surface of Ti makes it corrosion resistant in a variety of environments. β Ti alloys possess superior corrosion resistance as evident from the low corrosion rates in the range of 10 − 9 – 10 − 7 A/cm 2 [43,57,76,79,154 – 156].”
BackgroundLin, Z., Wang, L., Xiao-bing, X. U. E., Lü, W., Qin, J., & Zhang, D. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.07.010 · Cited by 83 · cited 1×
“Only a few reports have comprehensively investigated the e ff ect of SPD on the mechanical properties of β Ti alloys [102 – 108].”
BackgroundYan, L., Yuan, Y., Ouyang, L., Li, H., Mirzasadeghi, A., & Li, L. (2016) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2016.07.002 · Cited by 82
Liu, H., Niinomi, M., Nakai, M., Obara, S., & Fujii, H. (2017) · Materials Science and Engineering A · doi:10.1016/j.msea.2017.07.078 · Cited by 72 · cited 10×
“Liu et al. [142] enhanced the fatigue strength by increasing the interstitial O content in Ti – 29Nb – Table 7.”
BackgroundMethodInfluentialOsseointegration and Bioscience of Implant Surfaces - Current Concepts at Bone-Implant Interface
Ramazanoğlu, M., & Oshi, Y. (2011) · InTech eBooks · doi:10.5772/16936 · Cited by 67
In vitro performance assessment of new beta Ti–Mo–Nb alloy compositions
Neacsu, P., Gordin, D. M., Mitran, V., Gloriant, T., Costache, M., & Cîmpean, A. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.11.023 · Cited by 64 · cited 1×
“Various studies have concluded that several compositions of β Ti alloys are equally biocompatible in comparison to either cp-Ti or Ti – 6Al – 4V [57,79,154,182 – 185].”
BackgroundIn vitro and in vivo biological performance of porous Ti alloys prepared by powder metallurgy
do Prado, R. F., Campos, G. E., Santos, E. L. D. S., Bueno, D. A. G., Cairo, C. A. A., Vasconcellos, L. G. O. D., Sagnori, R. S., Tessarin, F. B. P., de Oliveira, F. E., de Oliveira, L. D., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0196169 · Cited by 59
Ion, R., Gordin, D. M., Mitran, V., Osiceanu, P., Dinescu, S., Gloriant, T., & Cîmpean, A. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.11.018 · Cited by 40
Preparation and characterization of alloys of the Ti–15Mo–Nb system for biomedical applications
Júnior, J. R. S. M., Matos, A. A., de Oliveira, R. C., Buzalaf, M. A. R., Costa, I., Rocha, L. A., & Grandini, C. R. (2017) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33868 · Cited by 31
Mohan, P. S., Elshalakany, A. B., Osman, T., Amigó, V., & Mohamed, A. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.09.255 · Cited by 27
In‐vitro and in‐vivo evaluation of a new Ti‐15Mo‐1Bi alloy
Lee, J.-W., Lin, D., Ju, C. P., Yin, H., Chuang, C.-C., & Lin, J. C. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31440 · Cited by 18 · cited 3×
“Unlike the β alloys, a reduction in bone area was noted in Ti – 6Al – 4V with an increase in duration from 12 weeks to 26 weeks [189,190].”
BackgroundInfluentialHisata, Y., Kobayashi, E., & Sato, T. (2015) · MATERIALS TRANSACTIONS · doi:10.2320/matertrans.m2015118 · Cited by 3
Cited by
Recent Progress on Wear‐Resistant Materials: Designs, Properties, and Applications
Zhai, W., Bai, L., Zhou, R., Fan, X., Kang, G., Liu, Y., & Zhou, K. (2021) · Advanced Science · doi:10.1002/advs.202003739 · Cited by 651
Methods and materials for additive manufacturing: A critical review on advancements and challenges
Bhuvanesh Kumar, M., & Sathiya, P. (2021) · Thin-Walled Structures · doi:10.1016/j.tws.2020.107228 · Cited by 372
Metadata
- Authors
- Bahl, S., Suwas, S., & Chatterjee, K.
- Venue
- International Materials Reviews
- Publisher
- SAGE Publications
- Published
- 2020-03-05
- Volume
- 66
- Issue
- 2
- Pages
- 114-139
- ISSN
- 0950-6608 (ISSN-L)
- 1743-2804
- OpenAlex
- W3010354515
- Cited by
- 187
- References
- 68
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.