The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparative ecotoxicity assessment of magnetosomes and magnetite nanoparticles
Abstract
Magnetite nanoparticles (MNPs) are gaining attention because of their biomedical, environmental and industrial applications. However, they have limited uses because of ecotoxicity. On contrast, bacterially synthesized MNPs such as magnetosomes are found to be biocompatible and less toxic due to the lipid bilayer membrane found around magnetite. In this context, this study compares the physio-chemical properties and toxicology effects of MNPs and magnetosomes in different models such as human red blood cells, macrophage cell lines (RAW 264.7), onion root tips ( Allium cepa), Artemia salina (A. salina ) and zebrafish embryo ( Danio rerio ). MNPs showed 38.59% hemolysis whereas the maximum hemolysis induced by magnetosomes was 7.03% for the same concentration (250 μg/ml). The cytotoxicity of MNPs and magnetosomes were 36.01% and 13.4%, respectively, at 250 μg/ml. Onion root tip assay revealed high toxicity when treated with MNPs than magnetosomes. The MNPs were further tested for its toxicity against A. salina and 50% mortality rate was observed. Similarly, notable malformation was seen in zebrafish embryo treated with MNPs. However, magnetosomes did not exhibit any mortality and malformation in A. salina and zebrafish embryo. The study revealed that magnetosomes are safe and do not cause any potential risk to environment compared to synthetic MNPs. Abbreviation: MNPs: Magnetic nanoparticles; ATCC: American Type Culture Collection; MTB: Magnetotactic bacteria; MSR-1: Magnetospir…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Only IML pegylation induced a slight increase on their hemolysis capacity (1% to ~2%), although within the normal range of hemolysis that is considered biocompatible (0–2%) [47].”
From Biomimetic Magnetoliposomes as Oxaliplatin Nanocarriers: In Vitro Study for Potential Application in Colon Cancer (2020) · cites this paper as [47]
Citations
Cites
Magnetic iron oxide nanoparticles: synthesis and surface functionalization strategies
Wu, W., He, Q., & Jiang, C. (2008) · Nanoscale Research Letters · doi:10.1007/s11671-008-9174-9 · Cited by 2,300
Flagged first, then by citations
Research works printed but not linked: 45
- Abu-Dief AM, 2018, Beni-Suef Univ J Basic and Appl Sci
- 10.1016/j.ijpharm.2012.06.015 · DOI
- 10.1186/1743-8977-6-1 · DOI · Paper page
- 10.1155/2014/256919 · DOI
- 10.1128/JB.141.3.1399-1408.1980 · DOI
- 10.1038/nrmicro842 · DOI
- 10.1016/j.biomaterials.2004.03.016 · DOI · Paper page
- 10.2138/am.2008.2678 · DOI
- 10.3390/s130506423 · DOI
- 10.1016/j.desal.2010.10.052 · DOI
- 10.1128/JB.170.2.834-841.1988 · DOI
- 10.1016/S0304-8853(98)00560-5 · DOI
- 10.1016/S0580-9517(08)70503-8 · DOI
- 10.1016/j.tiv.2005.06.034 · DOI
- 10.1007/s00216-009-3191-0 · DOI
- Komeili A, Li Z, Newman DK, Jensen GJ. 2006. Magnetosomes are cell membrane invaginations organized by the actin-like protein MamK. Science, 311(5758): 242–245. · DOI
- 10.1002/smll.201101059 · DOI
- 10.1016/S0927-7757(02)00305-9 · DOI
- 10.3390/molecules18077533 · DOI
- 10.1016/j.jes.2017.05.012 · DOI
- 10.1016/j.jiec.2013.09.035 · DOI
- 10.1126/science.1114397 · DOI · Paper page
- Noori A, 2011, Afr J Biotechnol, 10, 1221
- [OECD] Organisation for Economic Co-operation and Development, 1998, OECD Guideline for Testing of Chemicals 212: fish, short term toxicity test on embryo and sac-fry stages
- 10.1016/j.colsurfb.2009.03.004 · DOI
- 10.3390/ijms161024417 · DOI
- 10.1186/s40199-015-0105-x · DOI
- 10.1177/0960327115579208 · DOI
- 10.1080/10590500802708267 · DOI
- 10.1007/s13205-017-0780-z · DOI
- 10.1186/s12951-017-0305-2 · DOI
- 10.1016/j.tibtech.2008.04.005 · DOI
- Schulte C, 1994, Atla, 22, 12
- 10.1016/j.toxrep.2014.11.002 · DOI
- 10.2174/1381612821666150917094031 · DOI
- 10.1155/2011/469031 · DOI
- 10.1016/j.mycmed.2009.01.001 · DOI
- 10.1016/j.jmmm.2009.02.077 · DOI
- 10.1088/2043-6262/1/4/045013 · DOI
- 10.1016/j.toxrep.2015.03.015 · DOI
- 10.1111/j.1472-765X.2007.02143.x · DOI
- 10.1016/j.jmmm.2004.01.094 · DOI
- 10.1016/S1004-9541(08)60104-4 · DOI
- 10.1371/journal.pone.0046286 · DOI
- 10.1080/10934520701792779 · DOI
Cited by
Sorted by citations
Garcia-Pinel, B., Jabalera, Y., Ortiz, R., Cabeza, L., Jimenez-Lopez, C., Melguizo, C., & Prados, J. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060589 · Cited by 40
Metadata
- Authors
- Raguraman, V., & Suthindhiran, K.
- Affiliations
- Marine Biotechnology and Bioproducts Laboratory, School of Biosciences and Technology, Vellore Institute of Technology, Vellore, India
- Venue
- International Journal of Environmental Health Research
- Publisher
- Informa UK Limited
- Published
- 2019-02-04
- Volume
- 30
- Issue
- 1
- Pages
- 13-25
- ISSN
- 0960-3123
- 1369-1619
- Cited by
- 16
- References
- 1
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review