The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
Abstract
Self-monitoring blood glucose (SMBG) systems have the potential to play an important role in the management of diabetes and in the reduction of risk of serious secondary clinical complications. This review describes the transition from simple urine sugar screening tests to sophisticated meter and reagent strip systems to monitor blood glucose. Significant developments in design and technology over the past four decades are described since the first meter was introduced in 1970. Factors that have influenced this evolution and the challenges to improve analytical performance are discussed. Current issues in the role of SMBG from the clinical, patient and manufacturer perspectives, notably adherence, costs and regulations, are also considered.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Urine is a noninvasive fluid for inexpensive, easy to use glucose testing, that has historically dominated diabetes monitoring before the blood glucose sensors era (Figure 4F) 169.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [169]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Laboratory techniques in biochemistry and molecular biology
Work, T. S., & Work, E. (1973) · Food and Cosmetics Toxicology · doi:10.1016/0015-6264(73)90270-8 · Cited by 2,181
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Folin, O., & Wu, H. M. (1919) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)87378-1 · Cited by 1,191
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,132
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s106 · Cited by 1,037
Research works printed but not linked: 14
- IBMS History Committee, 2005, From matula to mass spectrometry: a history of urine tests in the investigation of human disease.
- Benedict SR., 1908, J Biol Chem, 277, e5
- Walter B., 1983, Anal Chem, 55, 498A
- Sonntag O., 1993, Analysis with carrier-bound reagents, 1
- Hill JB, 1961, J Lab Clin Med, 57, 970
- Cheah JS, 1974, Singapore Med J, 15, 51
- Thai AC, 1981, Singapore Med J, 22, 275
- 1982, Clin Chem, 28, 2448
- Forest RD, 1987, Diabetes Res, 6, 119
- American Diabetes Association, 1996, Diabetes Care, 19, 62
- Devreese K, 1993, Eur J Clin Chem Clin Biochem, 31, 829
- International Organisation for Standardisation, 2003, In vitro diagnostic test systems for blood glucose monitoring systems for self testing in managing diabetes mellitus.
- American Diabetes Association, 2010, Diabetes Care, 33, Sll
- National Institute for Health and Clinical Excellence, 2009, Type 2 diabetes: neiver agents for blood glucose control in type 2 diabetes (Partial update of CG66)
Cited by
Sorted by citations
Items 401–456 of 456
[Bilateral surgery of giant emphysema blisters and its late results].
Brunner, W. (1970) · PubMed
Newer Modalities in the Treatment of Type 2 Diabetes Mellitus: Focus on Technology
Schorr, A. B. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.84285
Roussarie, E. (2018) · theses.fr (ABES) · doi:10.70675/d28c302fze0e6z43caz8473z22ea305468ed
Proposal of Electrode System for Measuring Level of Glucose in the Blood
Fiedorova, K., & Augustýnek, M. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-3-030-14907-9_5
Measures of Glycemic Control and The Case for More Frequent Testing of HbA1c
Burd, J. F. (2019) · Nursing & Primary Care · doi:10.33425/2639-9474.1102
Appropriate Medical Technology in the Era of the 4th Industrial Revolution
Rhee, S. Y. (2019) · Korean Journal of Medicine · doi:10.3904/kjm.2019.94.5.387
Needle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquito
Rojas, J. T. D. C. (2020) · doi:10.11575/prism/37628
권선희, 김하늬, 고선영, 조치현, 김장수, & Seung, L. C. (2014)
Metabolic syndrome and the risk of kidney diseases: the impact of life style modification
Moaty, M. I. A., Shebini, S. M. E., Ahmed, N. H., Essa, H. A., & Tapozada, S. T. (2021) · Egyptian Journal of Chemistry · doi:10.21608/ejchem.2021.78093.3818
Boloya, V. E., Patricia, T. E., Kasia, B., Boye, S. I., & Proph, T. P. (2021) · International Journal of Research Publications · doi:10.47119/ijrp100781620211982
Nabais, J. M. V. (2020) · Boletim da Sociedade Portuguesa de Química · doi:10.52590/m3.p694.a30002333
Evolución de los sistemas de infusión de insulina: el camino al páncreas artificial
de la Maza-Viadero, M. E. S., Almeda-Valdés, P., & Faradji-Hazan, R. N. (2021) · Revista Mexicana de Endocrinología Metabolismo y Nutrición · doi:10.24875/rme.m21000015
Non-invasive microwave detection of blood glucose level
Oloyo, A. (2020) · Research Explorer (The University of Manchester)
Bee Products for Relieving Menopausal Symptoms
Fouad, S., Elgendy, A., Monir, R., Abdel-Wahhab, K. G., Shafei, H. F., & Hegazi, A. G. (2022) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2022.8191
Development of an electrochemical immunosensor for phenylketonuria monitoring
Stewart, A. (2021) · Queensland University of Technology · doi:10.5204/thesis.eprints.208391
Clinical applications of wearable and non-contact sensors
俊世, 田. (2020) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.90.11
“Past” and “Future” of Healthcare Electronics
ヘルスケアエレクトロニクス研究会 (2022) · Journal of The Japan Institute of Electronics Packaging · doi:10.5104/jiep.26.93
(2014) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781782621126-00092
Biosensors, customisation, and prototyping
Rogosic, R. (2023) · doi:10.26481/dis.20230404rr
Biosensors for Point‐of‐Care Applications: Replacing Pathology Labs by Bedside Devices
Sinha, M., Banerjee, S., Majumdar, S., & Kushagra, A. (2023) · doi:10.1002/9783527837946.ch9
Technik und Nachhaltigkeit im Gesundheits- und Pflegewesen
Elsbernd, A., Schmucker, M., & Zürn, T. (2023) · Springer Reference Pflege, Therapie, Gesundheit · doi:10.1007/978-3-662-64954-1_32-1
Nakamura, Y., & Furukawa, S. (2023) · World Journal of Diabetes · doi:10.4239/wjd.v14.i10.1562
Sensing techniques for environmental pollutants
Qu, K., & Dan, D. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-21966-5.00007-7
A IMPORTÂNCIA DO TRATAMENTO DO DIABETES MELLITUS TIPO 2: UMA REVISÃO DE LITERATURA
de Almeida, M. C., Silva, M. V. S., & de Oliveira, C. M. S. (2023) · Revista Ibero-Americana de Humanidades, Ciências e Educação · doi:10.51891/rease.v9i11.12026
Modeling, Estimation, and Feedback Techniques in Type 2 Diabetes
Ahdab, M. A. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau614554303
The History of Inpatient Diabetes
Brooks, D., Schulman‐Rosenbaum, R., Galindo, R. J., & Umpierrez, G. E. (2023) · Contemporary Endocrinology · doi:10.1007/978-3-031-44648-1_1
Biochipping in forensic medicine as a technology for determining readiness to cause harm: a review
Tukenova, Z. S., Джафарович, А. Х., Begaliyev, Y. N., Seralieva, A. M., & Shayakhmetova, Z. B. (2024) · Russian Journal of Forensic Medicine · doi:10.17816/fm16092
(2024) · Journal of Medical Clinical Case Reports · doi:10.47485//2767-5416.1062
Zhang, D., Yang, Y., Zhang, J., Chen, J., Huang, L., Zhang, L., & Liu, X. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4791181
Ball, C. M., & Featherstone, P. J. (2024) · Anaesthesia and Intensive Care · doi:10.1177/0310057x241235761
Upconversion properties of lanthanide-doped core/shell nanostructures and their emerging application
Tamboli, S., Nair, G. B., Dhoble, S. J., & Swart, H. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15830-8.00010-x
Technik und Nachhaltigkeit im Gesundheits- und Pflegewesen
Elsbernd, A., Schmucker, M., & Zürn, T. (2024) · Springer Reference Pflege, Therapie, Gesundheit · doi:10.1007/978-3-662-68278-4_32
Indications, specifics and reimbursement of glucose sensors in type 2 diabetes patients
Štechová, K. (2024) · Vnitřní lékařství · doi:10.36290/vnl.2024.077
Point-of-Care Assays for Examining Body Fluids and Cells
Ramanujam, N., & Crouch, B. (2024) · Cambridge University Press eBooks · doi:10.1017/9781108980746.005
A History of the GlucometerPreprint
Iudt, C. V. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4634309
Interpretation of Meters, Pumps, and Continuous Glucose Monitoring Downloads
Weaver, K., & Hirsch, I. B. (2019) · doi:10.2337/9781580406932.part1_ch08
Diagnostic Devices Based on Nanomaterial-Modified Ultramicroelectrode Used in Biomolecular Detection
Aliabadi, F., & Sohrabi, B. (2024) · Springer eBooks · doi:10.1007/978-981-97-7445-6_43
Chui, K. T., Gupta, B. B., Vasant, P., & Thomas, J. J. (2025) · Advances in intelligent systems and computing · doi:10.1007/978-3-031-40905-9_9
Highly Protein-resistant AuNPs-ampholytes Modified Boric Acid Hydrogel for Saliva Glucose Detection
Dou, Q., Chen, T., Liping, Z., Qing, D., & Hu, D. (2025) · Open Journal of Analytical and Bioanalytical Chemistry · doi:10.17352/ojabc.000033
Diabetes and Its Management through Continuous Glucose Monitoring Devices
-, D. N. P. (2025) · Journal of Advances in Developmental Research · doi:10.71097/ijaidr.v16.i1.1404 · Cited by 1
Insulin in Its Second Century: History, Evolution, and Aspirations
Mayer, J. P., Thalluri, K., Mickelson, E., Stowell, M. H. B., & DiMarchi, R. D. (2025) · Peptide Science · doi:10.1002/9781119824701.ch08
Yang, M.-M., Liang, W., Zhao, H. H., & Zhang, Y. (2020) · Figshare · doi:10.6084/m9.figshare.12644493
Non-Invasive Wearable Glucose Monitoring System Using NIR Spectroscopy and IoT Integration
Ahmed, T. M., Mahyoob, M., & Mohamed, K. A. (2025) · International Conference on Signal Processing and Information Security (ICSPIS) · doi:10.1109/icspis67605.2025.11318406
Moaty, M. I. A., Shebini, S. M. E., Mohamed, R. A., Sherity, S. Y. E., & Ahmed, N. H. (2026) · Scientific Reports · doi:10.1038/s41598-026-42141-7
Paper-Based Electrochemical Sensors
Korotcenkov, G. S. (2026) · Springer eBooks · doi:10.1007/978-3-032-02713-9_18
Kongdee, R., Bijan Parsia, A., Thabit, H., & Harper, S. (2026) · Scientific Data · doi:10.1038/s41597-026-07189-0
Hybrid deep learning-based blood glucose level monitoring using PPG signals
Soliman, A. Y., Nor, A. M., Omer, O. A., & Mubarak, A. S. (2026) · Signal Image and Video Processing · doi:10.1007/s11760-026-05368-5
El-Hassanein, A. M., Hammad, S. F., Mansour, F. R., & Abdella, A. A. (2026) · RSC Advances · doi:10.1039/d6ra00484a
In vitro and In vivo testing methods
Gao, W., Chen, W., & Rudramuni, K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36348-1.00006-2
Photoplethysmography (PPG) based noninvasive blood glucose monitoring
Ali, M., Hassan, F., & Nie, Z. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36348-1.00009-8
Olamoyegun, M., Olamoyegun, O. D., Akinlade, A. T., Saliu, O. O., & Adeyemi, T. A. (2026) · Cardiovascular Diabetology – Endocrinology Reports · doi:10.1186/s40842-026-00310-7
The Diabetes Technology Timeline
Sriravindrarajah, A., Forner, P. M., & SNAITH, J. R. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_1
A Novel Non-Invasive Technique for Assessing Blood Glucose Concentrations
Manurkar, V., & Bansod, P. P. (2026) · Applied Sciences · doi:10.3390/app16188960
Improving Inpatient Continuous Glucose Monitoring Documentation Through Targeted Nursing Education
MATTEI, L. D., Kashat, M., CELIK, B., Shelden, D., & Brennan, M. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.09.114
Metadata
- Authors
- Clarke, S. F., & Foster, J. R.
- Affiliations
- Institute of Biomedical Science (GB)
- Venue
- British Journal of Biomedical Science
- Publisher
- Frontiers Media SA
- Published
- 2012-01
- Volume
- 69
- Issue
- 2
- Pages
- 83-93
- ISSN
- 0967-4845 (ISSN-L)
- OpenAlex
- W103326292
- Cited by
- 456
- References
- 86
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 38 · 2023: 57 · 2022: 44 · 2021: 43 · 2020: 47 · 2019: 35 · 2018: 26 · 2017: 28 · 2016: 41 · 2015: 30 · 2014: 24 · 2013: 6
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- British Journal of Biomedical Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- blood glucose meters, self-monitoring of blood glucose, diabetes mellitus, test strips, analytical performance, patient adherence, cost, regulation, diabetes management
- MeSH terms
- Diabetes Mellitus, Equipment Design, Humans, Hyperglycemia, Hypoglycemic Agents, Insulin, Blood Glucose Self-Monitoring, Reproducibility of Results, History, 19th Century, History, 20th Century, History, 21st Century
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review