Application of the finite element method in dental implant research
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
This article provides a review of the achievements and advancements in dental technology brought about by computer-aided design and the all powerful finite element method (FEM) of analysis. The scope of the review covers dental implants, jawbone surrounding the implant and the biomechanical implant and jawbone interaction. Prevailing assumptions made in the published finite element analysis (FEA) and their limitations are discussed in some detail which helps identify the gaps in research as well as future research direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of matrix structural analysis
Przemieniecki, J. S. (1985) · UCLA Biblioteca de Ingenieria Civil · Cited by 1,626
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283 · cited 1×
“This might also have led to unrealistic results (Rho et al. 1993).”
Application of finite element analysis in implant dentistry: A review of the literature
Geng, J.-P., Tan, K. B. C., & Liu, G.-R. (2001) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.115251 · Cited by 1,106
The Excessive Loss of Branemark Fixtures in Type IV Bone: A 5‐Year Analysis
Jaffin, R. A., & Berman, C. L. (1991) · Journal of Periodontology · doi:10.1902/jop.1991.62.1.2 · Cited by 1,049
Wolff, J. (1986) · Springer eBooks · doi:10.1007/978-3-642-71031-5 · Cited by 802
Lindquist, L. W., Carlsson, G. E., & Jemt, T. (1996) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1996.070405.x · Cited by 697
Bone remodeling I: theory of adaptive elasticity
Cowin, S. C., & Hegedus, D. H. (1976) · Journal of Elasticity · doi:10.1007/bf00041724 · Cited by 665
Suggested guidelines for the topographic evaluation of implant surfaces.
Wennerberg, A., & Albrektsson, T. O. (2000) · PubMed · Cited by 462
Influence of implant length and diameter on stress distribution: A finite element analysis
Himmlová, L., Dostálová, T., Kácovský, A., & Konvic̆ková, S. (2004) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2003.08.008 · Cited by 443
Koolstra, J. H., van Eijden, T. M. G. J., Weijs, W. A., & Naeije, M. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90219-9 · Cited by 366
Recent development on computer aided tissue engineering — a review
Sun, W., & Lal, P. (2002) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(01)00116-x · Cited by 360
Holmgren, E. P., Seckinger, R. J., Kilgren, L. M., & Mante, F. (1998) · Journal of Oral Implantology · doi:10.1563/1548-1336(1998)024<0080:epoodi>2.3.co;2 · Cited by 347
The mechanism of bone remodeling and resorption around press-fitted THA stems
Van Rietbergen, B., Huiskes, R., Weinans, H., Sumner, D. R., Turner, T. M., & Galante, J. O. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90001-u · Cited by 299
Eskitascioglu, G., Usumez, A., Sevimay, M., Soykan, E., & Unsal, E. (2004) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2003.10.018 · Cited by 251
O'Sullivan, D., Sennerby, L., & Meredith, N. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01041.x · Cited by 235
Borchers, L., & Reichart, P. (1983) · Journal of Dental Research · doi:10.1177/00220345830620021401 · Cited by 223
Influence of Implant Length and Bicortical Anchorage on Implant Stress Distribution
Pierrisnard, L., Renouard, F., Renault, P., & Barquins, M. (2003) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2003.tb00208.x · Cited by 220
Mechanical properties of metaphyseal bone in the proximal femur
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90350-v · Cited by 199
Finite element analysis of six endosseous implants
Rieger, M. R., Mayberry, M., & Brose, M. O. (1990) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(90)90325-7 · Cited by 181
Rationale for the Application of Immediate Load In Implant Dentistry: Part I
Misch, C. E., Wang, H., Misch, C. M., Sharawy, M., Lemons, J. E., & Judy, K. W. M. (2004) · Implant Dentistry · doi:10.1097/01.id.0000140461.25451.31 · Cited by 179
Rokni, S. H., Todescan, R., Watson, P., Pharoah, M. J., Adegbembo, A. O., & Deporter, D. A. (2005) · PubMed · Cited by 151
The Role of the Finite Element Model in Dental Implants
DeTolla, D. H., Andreana, S., Patra, A., Buhite, R. J., & Comella, B. (2000) · Journal of Oral Implantology · doi:10.1563/1548-1336(2000)026<0077:trotfe>2.3.co;2 · Cited by 137
Finite element analysis of three‐ and four‐unit bridges
Farah, J. W., Craig, R. G., & Meroueh, K. A. (1989) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1989.tb01384.x · Cited by 121
Oral function in subjects with overdentures supported by osseointegrated implants
Haraldson, T., Jemt, T., STÅLBLAD, P., & Lekholm, U. (1988) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.1988.tb01550.x · Cited by 115
Zarone, F., Apicella, A., Nicolais, L., Aversa, R., & Sorrentino, R. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140114.x · Cited by 108
Concept of the Law of Bone Remodelling
Wolff, J. (1986) · Springer eBooks · doi:10.1007/978-3-642-71031-5_1 · Cited by 100
In vivo horizontal bending moments on implants.
Richter, E. (1998) · PubMed · Cited by 99
Mandibular deformation in subjects with osseointegrated implants.
Hobkirk, J. A., & Schwab, J. (1991) · PubMed · Cited by 89
Periodontal ligament stresses in the initiation of occlusal traumatism
Reinhardt, R. A., Pao, Y. C., & Krejci, R. F. (1984) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1984.tb00815.x · Cited by 38
Adaptive reconstruction of bone geometry from serial cross-sections
Knopf, G. K., & Al-Naji, R. (2001) · Artificial Intelligence in Engineering · doi:10.1016/s0954-1810(01)00006-1 · Cited by 20
Cited by
Baggi, L., Cappelloni, I., Di Girolamo, M., Maceri, F., & Vairo, G. (2008) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)60259-0 · Cited by 535
State of the Art of Micro‐CT Applications in Dental Research
Swain, M. V., & Xue, J. (2009) · International Journal of Oral Science · doi:10.4248/ijos09031 · Cited by 412
Finite element analysis: A boon to dentistry
Trivedi, S. (2014) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2014.11.008 · Cited by 240
Cicciù, M., Cervino, G., Bramanti, E., Lauritano, F., Lo Gudice, G., Scappaticci, L., Rapparini, A., Guglielmino, E., & Risitano, G. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/943839 · Cited by 86
FEM and VonMises analyses of different dental implant shapes for masticatory loading distribution
CICCI�, M. (2014) · Oral & Implantology · doi:10.11138/orl/2014.7.1.001 · Cited by 62
Metadata
- Authors
- Van Staden, R. C., Guan, H., & Loo, Y. C.
- Venue
- Computer Methods in Biomechanics and Biomedical Engineering
- Publisher
- Informa UK Limited
- Published
- 2006-08
- Volume
- 9
- Issue
- 4
- Pages
- 257-270
- ISSN
- 1025-5842 (ISSN-L)
- 1476-8259
- OpenAlex
- W2068373826
- Cited by
- 298
- References
- 30
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.