Verification, validation and sensitivity studies in computational biomechanics
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Computational techniques and software for the analysis of problems in mechanics have naturally moved from their origins in the traditional engineering disciplines to the study of cell, tissue and organ biomechanics. Increasingly complex models have been developed to describe and predict the mechanical behavior of such biological systems. While the availability of advanced computational tools has led to exciting research advances in the field, the utility of these models is often the subject of criticism due to inadequate model verification and validation (V&V). The objective of this review is to present the concepts of verification, validation and sensitivity studies with regard to the construction, analysis and interpretation of models in computational biomechanics. Specific examples from the field are discussed. It is hoped that this review will serve as a guide to the use of V&V principles in the field of computational biomechanics, thereby improving the peer acceptance of studies that use computational modeling techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Software Engineering Economics
Boehm, B. W. (2001) · Pioneers and Their Contributions to Software Engineering · doi:10.1007/978-3-642-48354-7_5 · Cited by 5,981
Finite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797 · cited 4×
“A complete description of the constitutive equation and its FE implementation can be found in Weiss et al. (1996).”
BackgroundInfluentialSelf-citationPeña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Cited by
FEBio: Finite Elements for Biomechanics
Maas, S. A., Ellis, B. J., Ateshian, G. A., & Weiss, J. A. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4005694 · Cited by 1,105
Self-citationHicks, J. L., Uchida, T. K., Seth, A., Rajagopal, A., & Delp, S. L. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029304 · Cited by 748
Validation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip Joint
Anderson, A. E., Ellis, B. J., Maas, S. A., Peters, C. L., & Weiss, J. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2953472 · Cited by 275
Self-citationConsiderations for reporting finite element analysis studies in biomechanics
Erdemir, A., Guess, T. M., Halloran, J., Tadepalli, S. C., & Morrison, T. M. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.038 · Cited by 234
“In biomechanics, the procedures to conduct verification and validation studies and current practice of verification and validation have been described in detail by Anderson et al. (2007) and Henninger et al. (2010).”
MethodReview on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218
“These efforts have helped to gain information on complex physiological properties or conditions, which would have been otherwise unable to study [14] In this review, we provide an overview of the experimental and modeling efforts explored within the field of cell mechanics.”
Background
Metadata
- Authors
- Anderson, A. E., Ellis, B. J., & Weiss, J. A.
- Venue
- Computer Methods in Biomechanics and Biomedical Engineering
- Publisher
- Informa UK Limited
- Published
- 2007-06
- Volume
- 10
- Issue
- 3
- Pages
- 171-184
- ISSN
- 1025-5842 (ISSN-L)
- 1476-8259
- OpenAlex
- W2166093601
- Cited by
- 237
- References
- 3
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.