Verification, validation and sensitivity studies in computational biomechanics
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Computational techniques and software for the analysis of problems in mechanics have naturally moved from their origins in the traditional engineering disciplines to the study of cell, tissue and organ biomechanics. Increasingly complex models have been developed to describe and predict the mechanical behavior of such biological systems. While the availability of advanced computational tools has led to exciting research advances in the field, the utility of these models is often the subject of criticism due to inadequate model verification and validation (V&V). The objective of this review is to present the concepts of verification, validation and sensitivity studies with regard to the construction, analysis and interpretation of models in computational biomechanics. Specific examples from the field are discussed. It is hoped that this review will serve as a guide to the use of V&V principles in the field of computational biomechanics, thereby improving the peer acceptance of studies that use computational modeling techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Logic of Scientific Discovery
(2013) · A Realist Theory of Science · doi:10.4324/9780203090732-9 · Cited by 7,731
Software Engineering Economics
Boehm, B. W. (2001) · Pioneers and Their Contributions to Software Engineering · doi:10.1007/978-3-642-48354-7_5 · Cited by 5,981
Verification, Validation, and Confirmation of Numerical Models in the Earth Sciences
Oreskes, N., Shrader-Frechette, K., & Belitz, K. (1994) · Science · doi:10.1126/science.263.5147.641 · Cited by 3,010
Monte Carlo Strategies in Scientific Computing
Liu, J. S. (2004) · Springer Series in Statistics · doi:10.1007/978-0-387-76371-2 · Cited by 2,690
Verification and Validation in Computational Science and Engineering
Roache, P. J. (1998) · Cited by 2,157
Monte Carlo Strategies in Scientific Computing
Hesterberg, T. (2002) · Technometrics · doi:10.1198/tech.2002.s85 · Cited by 1,409 · cited 3×
“…can be singled out from other contributors of uncertainty by their representation as randomly distributed quantities (i.e. probability distributions) using Monte Carlo simulations (Liu 2001) or they can be simulated using a known range of values by way of sensitivity analyses (see Section 6).”
BackgroundMethodStern, F., Wilson, R. V., Coleman, H. W., & Paterson, E. G. (2001) · Journal of Fluids Engineering · doi:10.1115/1.1412235 · Cited by 935 · cited 1×
“The field of computational fluid dynamics (CFD) was the first to initiate formal discussions and requirements regarding V&V (American Institute of Aeronautics and Astronautics 1998, Roache 1998, Stern et al. 1999, 2001, Wilson et al. 2001, Oberkampf et al. 2002).”
Method(2016) · Systems Engineering for Commercial Aircraft · doi:10.4324/9781315611716-18 · Cited by 804
Finite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797 · cited 4×
“A complete description of the constitutive equation and its FE implementation can be found in Weiss et al. (1996).”
BackgroundInfluentialSelf-citationVerification, validation, and predictive capability in computational engineering and physics
Oberkampf, W. L., Trucano, T. G., & Hirsch, C. (2004) · Applied Mechanics Reviews · doi:10.1115/1.1767847 · Cited by 719 · cited 41×
“Non-deterministic metrics are the most comprehensive measure of agreement between computational predictions and experimental results (Oberkampf et al. 2002).”
BackgroundMethodInfluential
Cited by
FEBio: Finite Elements for Biomechanics
Maas, S. A., Ellis, B. J., Ateshian, G. A., & Weiss, J. A. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4005694 · Cited by 1,105
Self-citationHicks, J. L., Uchida, T. K., Seth, A., Rajagopal, A., & Delp, S. L. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029304 · Cited by 748
Validation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip Joint
Anderson, A. E., Ellis, B. J., Maas, S. A., Peters, C. L., & Weiss, J. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2953472 · Cited by 275
Self-citationConsiderations for reporting finite element analysis studies in biomechanics
Erdemir, A., Guess, T. M., Halloran, J., Tadepalli, S. C., & Morrison, T. M. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.038 · Cited by 234
“In biomechanics, the procedures to conduct verification and validation studies and current practice of verification and validation have been described in detail by Anderson et al. (2007) and Henninger et al. (2010).”
MethodBurkhart, T. A., Andrews, D. M., & Dunning, C. E. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.03.022 · Cited by 222
“…finite element models provide a feasible alternative for predicting the response of bone under a variety of loading conditions and have become a popular and powerful tool among biomechanics and orthopedics researchers over the last 20 to 30 years (Anderson et al., 2007; Erdemir et al., 2012).”
BackgroundMethodInfluentialReview on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218
“These efforts have helped to gain information on complex physiological properties or conditions, which would have been otherwise unable to study [14] In this review, we provide an overview of the experimental and modeling efforts explored within the field of cell mechanics.”
BackgroundValidation of computational models in biomechanics
Henninger, H. B., Reese, S. P., Anderson, A. E., & Weiss, J. A. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim649 · Cited by 204
Self-citationFinite element modeling of soft tissues: Material models, tissue interaction and challenges
Freutel, M., Schmidt, H., Dürselen, L., Ignatius, A., & Galbusera, F. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.01.006 · Cited by 184
“More detailed descriptions about the procedures of validation are provided by Anderson et al. (2007), Erdemir et al.”
MethodUse of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue Injury
Sparks, J. L., Vavalle, N. A., Kasting, K. E., Long, B., Tanaka, M. L., Sanger, P. A., Schnell, K., & Conner-Kerr, T. A. (2015) · Advances in Skin & Wound Care · doi:10.1097/01.asw.0000460127.47415.6e · Cited by 168
“Statistical Analysis To assess the accuracy of the mechanical property values implemented in the FE simulations for each synthetic tissue analog, linear regression analyses of model output versus experimental values were conducted for each simulation.(18) A slope value near unity indicated a one-to-one relationship be…”
MethodErdemir, A., Mulugeta, L., Ku, J. P., Drach, A., Horner, M., Morrison, T. M., Peng, G. C. Y., Vadigepalli, R., Lytton, W. W., & Myers, J. G. (2020) · Journal of Translational Medicine · doi:10.1186/s12967-020-02540-4 · Cited by 118
Cucurull‐Sanchez, L., Chappell, M. J., Chelliah, V., Amy Cheung, S. Y., Derks, G., Penney, M., Phipps, A., Malik‐Sheriff, R. S., Timmis, J., Tindall, M. J., et al. (2019) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12381 · Cited by 61
“Here, we refer to model verification as the process in which the modeler determines the degree of self- consistency and robustness of the model prior to assessing its performance against experimental observations.(43,45)”
Method
Metadata
- Authors
- Anderson, A. E., Ellis, B. J., & Weiss, J. A.
- Venue
- Computer Methods in Biomechanics and Biomedical Engineering
- Publisher
- Informa UK Limited
- Published
- 2007-06
- Volume
- 10
- Issue
- 3
- Pages
- 171-184
- ISSN
- 1025-5842 (ISSN-L)
- 1476-8259
- OpenAlex
- W2166093601
- Cited by
- 237
- References
- 42
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.