Mycobacterial Aerosol Collection Efficiency of Respirator and Surgical Mask Filters under Varying Conditions of Flow and Humidity
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Collection efficiency was measured for a wide range of surgical masks and certified respirator filters using a 0.55-μm latex sphere aerosol at 45 L/min. Results were used to select representative filters and surgical masks for subsequent biological aerosol challenges. Collection efficiency of 16 respirator filters and 5 surgical masks was determined using a Mycobacterium abscessus aerosol at 45 and 85 L/min and 30 and 70 percent relative humidity. The bioaerosol was measured using two instruments: (1) an aerodynamic particle sizer, which detects both biological and nonbiological aerosols, and (2) a modified six-stage Andersen sampler, which detects only those aerosols able to replicate. Filter penetration of the latex and biological aerosols was highest and most variable for the surgical masks. Latex aerosol penetration through respirator filters ranged from 0.3 to 10 percent for dust/mist (DM) filters and from 0.09 to 3.4 percent for dust/fume/mist (DFM) filters; high efficiency particulate air (HEPA) filter penetration was always less than 0.01 percent. Median penetration of the biological aerosol was 2, 0.4, and 0.02 percent for DM, DFM, and HEPA filters, respectively. Higher flow resulted in higher penetration for all filters (as expected) and changes in relative humidity exerted only minimal influence on the collection of bioaerosols. The two sampling instruments gave similar values of filter efficiency; the total particle counter was generally less variable than the via…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, previous studies have shown agreement between physical penetrations of inert and biological aerosols at particle sizes of 1 µm and above.(13,16,24,31,32)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [31]
Citations
Cites
Simultaneous Statistical Inference
Miller, R. G. (1981) · Springer Series in Statistics · doi:10.1007/978-1-4613-8122-8 · Cited by 5,604
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Simultaneous Statistical Inference
Weeks, D. L., & Miller, R. G. (1967) · Biometrics · doi:10.2307/2528445 · Cited by 1,361
NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES,
Andersen, A. A. (1958) · Journal of Bacteriology · doi:10.1128/jb.76.5.471-484.1958 · Cited by 1,311
De, N., Rs, K., Rl, L., Chrismon, J. H., Merritt, R., Da, A., & Giovino, G. A. (1994) · PubMed · Cited by 797
Positive-Hole Correction of Multiple-Jet Impactors for Collecting Viable Microorganisms
MACHER, J. M. (1989) · American Industrial Hygiene Association Journal · doi:10.1080/15298668991375164 · Cited by 256
Annals of occupational hygiene
(1982) · Journal of Sound and Vibration · doi:10.1016/0022-460x(82)90337-6 · Cited by 146
Aerosol Science for Industrial Hygienists
(1995) · Elsevier eBooks · doi:10.1016/b978-0-08-042029-5.x5000-4 · Cited by 133
Aerodynamic particle size measurement by laser-doppler velocimetry
Wilson, J. C., & Liu, B. Y. H. (1980) · Journal of Aerosol Science · doi:10.1016/0021-8502(80)90030-0 · Cited by 124
Chen, S.-K., Vesley, D., Brosseau, L. M., & Vincent, J. H. (1994) · American Journal of Infection Control · doi:10.1016/0196-6553(94)90116-3 · Cited by 124
Self-citation
Research works printed but not linked: 7
- Brosseau L. M., Journal of the American Biological Safety Association
- 1994, Morbidity and Mortality Weekly Report, 43, 1
- 1992, NIOSH Recommended Guidelines for Personal Respiratory Protection of Workers in Health-Care Facilities Potentially Exposed to Tuberculosis. DHHS(NIOSH)
- 1995, Respiratory Protective Devices, Final Rule. 42 Code of Federal Regulations Part 84, RIN 0905-AB58. DHHS(NIOSH)
- Stevens G. A., 1989, Sodium Chloride and Dioctyl Phthalate Aerosol Filter Efficiency as a Function of Particle Size and Flowrate. Am. Ind. Hyg. Assoc. J, 50, 257
- McCullough N. V., Am. Ind. Hyg. Assoc. J
- Runyon E. H., 1974, Bergey's Manual of Determinative Bacteriology, pp. 681-701
Cited by
Loeb, M., Dafoe, N., Mahony, J., John, M., Sarabia, A., Glavin, V., Webby, R., Smieja, M., Earn, D. J. D., Chong, S., et al. (2009) · JAMA · doi:10.1001/jama.2009.1466 · Cited by 465
Bałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mei058 · Cited by 234
“…and Willeke, 1992; Qian et al., 1997b, 1998; Barrett and Rousseau, 1998; Huang et al., 1998; Han, 2000; Martin and Moyer, 2000) as well as biological particles (Brosseau et al., 1997; McCullough et al., 1997; Qian et al., 1997a, 1998; Reponen et al., 1999; Wang et al., 1999; Lee et al., 2004a).”
BackgroundA comparison of facemask and respirator filtration test methods
Rengasamy, S., Shaffer, R., Williams, B., & Smit, S. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1225157 · Cited by 198
“However, previous studies with approximately similar size FFRs and SMs showed significantly higher penetrations or lower efficiencies for SMs.[25,28,38] Products with poor or mediocre filtration performance such as the SM models in this study can be consistently identified using only a more challenging method such as…”
BackgroundMethodInfluentialFace Masks and the Cardiorespiratory Response to Physical Activity in Health and Disease
Hopkins, S. R., Dominelli, P. B., Davis, C. K., Guenette, J. A., Luks, A. M., Molgat-Seon, Y., Sá, R. C., Sheel, A. W., Swenson, E. R., & Stickland, M. K. (2021) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202008-990cme · Cited by 190
Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators
Bergman, M. S., Viscusi, D. J., Heimbuch, B. K., Wander, J. D., Sambol, A. R., & Shaffer, R. E. (2010) · Journal of Engineered Fibers and Fabrics · doi:10.1177/155892501000500405 · Cited by 177
Respiratory protection against bioaerosols: Literature review and research needs
Rengasamy, A., Zhuang, Z., & BerryAnn, R. (2004) · American Journal of Infection Control · doi:10.1016/j.ajic.2004.04.199 · Cited by 138
“In another study, the penetration of Mycobacterium abscessus aerosol through 16 respirator filters and 5 surgical masks were determined at 2 different flow rates and at a different relative humidity.(27) The median penetration of M abscessus was 2%, 0.”
BackgroundLin, T.-H., Chen, C.-C., Huang, S.-H., Kuo, C.-W., Lai, C.-Y., & Lin, W.-Y. (2017) · PLoS ONE · doi:10.1371/journal.pone.0186217 · Cited by 118
MCCULLOUGH, N., BROSSEAU, L., & VESLEY, D. (1997) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(97)00022-7 · Cited by 75
“/min) and two conditions of relative humidity (30±5 and 70±5%) (McCullough et al., in review; Brosseau et al., 1997).”
BackgroundMethodInfluentialSelf-citationExpiratory aerosol particle escape from surgical masks due to imperfect sealing
Cappa, C. D., Asadi, S., Barreda, S., Wexler, A. S., Bouvier, N. M., & Ristenpart, W. D. (2021) · Scientific Reports · doi:10.1038/s41598-021-91487-7 · Cited by 68
How much COVID-19 face protections influence speech intelligibility in classrooms?
Caniato, M., Marzi, A., & Gasparella, A. (2021) · Applied Acoustics · doi:10.1016/j.apacoust.2021.108051 · Cited by 57
“This variety of protections not only has an impact on the filtering of aerosol particles [5], but also on communication capabilities.”
BackgroundMajchrzycka, K., Okrasa, M., Szulc, J., & Gutarowska, B. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13010098 · Cited by 47
Samaranayake, L. P., Fakhruddin, K. S., Ngo, H. C., Chang, J. W. W., & Panduwawala, C. (2020) · Acta Odontologica Scandinavica · doi:10.1080/00016357.2020.1810769 · Cited by 39
Ratnesar-Shumate, S. A., Wu, C., Wander, J., Lundgren, D. A., Farrah, S. R., Lee, J., Wanakule, P., Blackburn, M. B., & Lan, M.-F. (2008) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2007.08.0036 · Cited by 39
“…media against inert particles (Qian et al., 1998; Richardson et al., 2006; Rengasamy et al., 2007) and against aerosols containing MS2 coli phage (Brosseau et al., 1997; Balazy et al., 2006) showed less than 2% penetration at airflow rates near 30 L/min for the most penetrating size (~ 50 nm),…”
BackgroundYassi, A., Bryce, E., Moore, D., Janssen, R., Copes, R., Bartlett, K. H., Fitzgerald, M., Gilbert, M., Bigelow, P., Danyluk, Q., et al. (2004) · TMUshare (Toronto Metropolitan University) · doi:10.32920/23935254.v1 · Cited by 43
Jeong, S. B., Ko, H. S., Seo, S., & Jung, J. H. (2019) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2019.05.153 · Cited by 36
Eninger, R. M., Adhikari, A., Reponen, T. A., & Grinshpun, S. A. (2008) · CLEAN - Soil Air Water · doi:10.1002/clen.200700198 · Cited by 35
Bacterial Survival on Respirator Filters and Surgical Masks
Brosseau, L. M., McCullough, N. V., & Vesley, D. (1997) · Applied Biosafety · doi:10.1177/109135059700200308 · Cited by 38
Self-citationLenhart, S. W., Seitz, T. A., Trout, D. B., & Bollinger, N. (2004) · Applied Biosafety · doi:10.1177/153567600400900104 · Cited by 32
Commentary: The Use of Respirators to Reduce Inhalation of Airborne Biological Agents
Janssen, L., Ettinger, H. J., Graham, S., Shaffer, R. E., & Zhuang, Z. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.799964 · Cited by 33
“The program must include the following provisions, as applicable to the devices in use: (1) selection procedures; (2) medical evaluations of employees required to use respirators; (3) fit testing procedures for tightfitting respirators; (4) procedures for proper use of respirators in routine and reasonably foreseeable…”
Viable Viral Efficiency of N95 and P100 Respirator Filters at Constant and Cyclic Flow
Gardner, P. D., Eshbaugh, J. P., Harpest, S. D., Richardson, A. W., & Hofacre, K. C. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.818228 · Cited by 31
“(15) (16) (17) (18) (19) (20) (21) (22) The FFRs for the most part have been shown to provide protection at or better than their NIOSH certification rating.”
BackgroundSelecting Respirators for Control of Worker Exposure to Infectious Aerosols
McCullough, N. V., & Brosseau, L. M. (1999) · Infection Control and Hospital Epidemiology · doi:10.1086/501602 · Cited by 24
Self-citationLin, T.-H., Tang, F., Chiang, C.-H., Chang, C., & Lai, C.-Y. (2016) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2015.03.0196 · Cited by 19
“Few investigations have focused on the survival of bacteria that are captured by a disposable FFR (Pasanen et al ., 1993; Brosseau et al ., 1997a).”
InfluentialLore, M. B., Sebastian, J. M., Brown, T. L., Viner, A. S., McCullough, N. V., & Hinrichs, S. H. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.640273 · Cited by 17
“Moreover, previous studies have shown agreement between physical penetrations of inert and biological aerosols at particle sizes of 1 μm and above.(13,16,24,31,32)”
Self-citationMajchrzycka, K., Okrasa, M., Szulc, J., & Gutarowska, B. (2017) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2017.02.008 · Cited by 16
Wen, Z., Lu, J., Li, J., Li, N., Zhao, J., Wang, J., Yu, L., & Yang, W. (2010) · Aerobiologia · doi:10.1007/s10453-010-9160-4 · Cited by 14
“Studies on respiratory protection against TB were carried out with nonpathogenic bacteria having physical characteristics similar to those of M. tuberculosis (Chen et al. 1994; Qian et al. 1998; Brosseau et al. 1997).”
Wen, Z., Yang, W., Li, N., Wang, J., Hu, L., Li, J., Yin, Z., Zhang, K., & Dong, X. (2013) · Particuology · doi:10.1016/j.partic.2012.11.009 · Cited by 16
Evaluation of a New Bioactive Nonwoven Fabric for Respiratory Protection
Majchrzycka, K. (2014) · Fibres and Textiles in Eastern Europe · Cited by 11
Performance of Composite Filters Assembled from Multiple Layers of Basic Filtration Media
Wang, P., Liu, Z., & Chen, D. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2020.07.0368 · Cited by 10
“The filtration performance of FFRs has been widely investigated (e.g., Brosseau et al. , 1997; Balazy et al. , 2006a, b; Eninger et al. , 2008; Rengasamy et al. , 2008; Eshbaugh et al. , 2009; Rengasamy et al. , 2009; Cho et al. , 2010; He et al. , 2013; Zuo et al. , 2013).”
Majchrzycka, K., & Brochocka, A. (2015) · Fibres and Textiles in Eastern Europe · doi:10.5604/12303666.1161766 · Cited by 7
Collection Efficiency Comparison of N95 Respirators Saturated with Artificial Perspiration
Larson, D. L. (2020) · ACS Chemical Health & Safety · doi:10.1021/acs.chas.0c00054 · Cited by 5
Respirator Filter Reuse Test Using the Laboratory Simulant Mycobacterium Tuberculosis (H37RA Strain)
Johnson, B., Winters, D. R., Shreeve, T. R., & Coffey, C. C. (1998) · Applied Biosafety · doi:10.1177/109135059800300306 · Cited by 5
Evaluation of at-home methods for N95 filtering facepiece respirator decontamination
Chen, T. X., Pinharanda, A., Steinemann, N. A., Yasuma-Mitobe, K., Lee, E., Hahn, J., Wu, L., Fanourakis, S., Peterka, D. S., & Hillman, E. M. C. (2021) · Scientific Reports · doi:10.1038/s41598-021-99129-8 · Cited by 3
Personal Respiratory Protection
McCullough, N. V. (2016) · ASM Press eBooks · doi:10.1128/9781555819637.ch21 · Cited by 3
Self-citationCurrent Issues in Exposure Assessment for Workplace Aerosols
Vincent, J. H., Brosseau, L. M., Ramachandran, G., Tsai, P., Spear, T. M., Werner, M., & McCullough, N. V. (1997) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/41.inhaled_particles_viii.607 · Cited by 2
Self-citationEvaluation of Low-Pressure Drop Antimicrobial and Hybrid Air Filters
Sullivan, P. D. (2006) · Defense Technical Information Center (DTIC) · Cited by 1
Wen, Z., Li, N., Li, J., Wang, J., Zhao, J., Yang, W., Hu, L., Dong, X., & Lu, J. (2012) · Applied Biosafety · doi:10.1177/153567601201700106 · Cited by 1
“Studies on respiratory protection against TB were carried out with nonpathogenic bacteria having 29 www.absa.org Applied Biosafety Vol. 17, No. 1, 2012 physical characteristics similar to that of M. tuberculosis (Brosseau et al., 1997; Chen et al., 1994; Qian et al., 1998).”
ResultClynes, N. D., & Bitar, R. A. (2010)
“Advances in Pneumonology”—Over 20 Years Long Tradition
Pneumonologia i Alergologia Polska Editorial Office (2010) · Advances in respiratory medicine · doi:10.5603/arm.27701
Personal Respiratory Protection
McCullough, N. V. (2014) · ASM Press eBooks · doi:10.1128/9781555815899.ch17
Self-citationZielonka, T. M. (2011) · Advances in respiratory medicine · doi:10.5603/arm.27620
Metadata
- Authors
- Brosseau, L. M., McCullough, N. V., & Vesley, D.
- Affiliations
- University of Minnesota (US)
- ORCID
- Brosseau, Lisa M.
- Venue
- Applied Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 1997-06
- Volume
- 12
- Issue
- 6
- Pages
- 435-445
- ISSN
- 1047-322X (ISSN-L)
- 1521-0898
- OpenAlex
- W2079448090
- Semantic Scholar
- 6176aec2edb48e83f51396e6595c68cb99001173
- Cited by
- 43
- References
- 22
- Citations by year
- 2023: 2 · 2021: 3 · 2020: 4 · 2019: 1 · 2017: 2 · 2016: 4 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 1
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Occupational and Environmental Hygiene (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Keywords
- respirator filters, surgical masks, aerosol filtration efficiency, filter penetration, bioaerosols, Mycobacterium abscessus, HEPA filters, flow rate effects, relative humidity effects, aerodynamic particle sizer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.