The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A comparison of facemask and respirator filtration test methods
Open accessAbstract
NIOSH published a Federal Register Notice to explore the possibility of incorporating FDA required filtration tests for surgical masks (SMs) in the 42 CFR Part 84 respirator certification process. There have been no published studies comparing the filtration efficiency test methods used for NIOSH certification of N95 filtering facepiece respirators (N95 FFRs) with those used by the FDA for clearance of SMs. To address this issue, filtration efficiencies of "N95 FFRs" including six N95 FFR models and three surgical N95 FFR models, and three SM models were measured using the NIOSH NaCl aerosol test method, and FDA required particulate filtration efficiency (PFE) and bacterial filtration efficiency (BFE) methods, and viral filtration efficiency (VFE) method. Five samples of each model were tested using each method. Both PFE and BFE tests were done using unneutralized particles as per FDA guidance document. PFE was measured using 0.1 µm size polystyrene latex particles and BFE with ∼3.0 µm size particles containing Staphylococcus aureus bacteria. VFE was obtained using ∼3.0 µm size particles containing phiX 174 as the challenge virus and Escherichia coli as the host. Results showed that the efficiencies measured by the NIOSH NaCl method for "N95 FFRs" were from 98.15-99.68% compared to 99.74-99.99% for PFE, 99.62-99.9% for BFE, and 99.8-99.9% for VFE methods. Efficiencies by the NIOSH NaCl method were significantly (p = <0.05) lower than the other methods. SMs showed lower efficiencies (54.72-88.40%) than "N95 FFRs" measured by the NIOSH NaCl method, while PFE, BFE, and VFE methods produced no significant difference. The above results show that the NIOSH NaCl method is relatively conservative and is able to identify poorly performing filtration devices. The higher efficiencies obtained using PFE, BFE and VFE methods show that adding these supplemental particle penetration methods will not improve respirator certification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq044 · Cited by 352
Self-citationSurgical mask filter and fit performance
Oberg, T., & Brosseau, L. M. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.07.008 · Cited by 310
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
Electrostatic Respirator Filter Media: Filter Efficiency and Most Penetrating Particle Size Effects
Martin, S. B., & Moyer, E. S. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050075617 · Cited by 156
Filtration Performance of FDA-Cleared Surgical Masks
Rengasamy*, S., Miller, A., Eimer, B. C., & Shaffer, R. E. (2009) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167200 · Cited by 69
Self-citationRengasamy, S., Eimer, B. C., & Szalajda, J. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.866715 · Cited by 61
Self-citationSrinivasan, A., Jernign, D. B., Liedtke, L., & Strausbaugh, L. (2004) · Clinical Infectious Diseases · doi:10.1086/421777 · Cited by 51
Brosseau, L. M., McCullough, N. V., & Vesley, D. (1997) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1997.10389533 · Cited by 43 · cited 6×
“However, previous studies with approximately similar size FFRs and SMs showed significantly higher penetrations or lower efficiencies for SMs.[25,28,38] Products with poor or mediocre filtration performance such as the SM models in this study can be consistently identified using only a more challenging method such as…”
BackgroundMethodInfluential
Cited by
SARS-CoV-2 (COVID-19) by the numbers
Bar-On, Y. M., Flamholz, A., Phillips, R., & Milo, R. (2020) · eLife · doi:10.7554/elife.57309 · Cited by 962
Zangmeister, C. D., Radney, J. G., Vicenzi, E. P., & Weaver, J. L. (2020) · ACS Nano · doi:10.1021/acsnano.0c05025 · Cited by 276
Yim, W., Cheng, D., Patel, S., Kui, R., Meng, Y. S., & Jokerst, J. V. (2020) · medRxiv · doi:10.1101/2020.07.07.20148551 · Cited by 104
Metadata
- Authors
- Rengasamy, S., Shaffer, R., Williams, B., & Smit, S.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2016-12-20
- Volume
- 14
- Issue
- 2
- Pages
- 92-103
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2513967391
- Cited by
- 198
- References
- 9
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of facemask and respirator filtration test methods. https://app.cochat.ai/papers/10.1080/15459624.2016.1225157
- The paper
- Rengasamy, S., Shaffer, R., Williams, B., & Smit, S. (2017). A comparison of facemask and respirator filtration test methods. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459624.2016.1225157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.