Cited by 16Blood Pressure and Hypertension StudiesCardiovascular Health and Disease PreventionNon-Invasive Vital Sign Monitoring

Comparison of nocturnal blood pressure based on home versus ambulatory blood pressure measurement: The Ohasama Study

Open access
Hosohata, Keiko, Kikuya, Masahiro, Asayama, Kei, Metoki, Hirohito, Imai, Yutaka, Ohkubo, Takayoshi·2020·Clinical and Experimental Hypertension

Abstract

Objectives The nocturnal blood pressure (BP) is a strong predictor of hypertensive target organ damage including that in cardiovascular diseases. The use of ambulatory BP (ABP) monitoring has enabled the evaluation of nocturnal BP and detection of non-dippers. This study compared nocturnal BP values, nocturnal decline in BP, and the prevalence of non-dippers based on ABP and home BP (HBP) measurements in a general population. Methods Data on HBP measured with HEM 747-IC-N (Omron Healthcare Co., Ltd.) and 24-hour ABP measured with ABPM-630 (Nippon Colin) were obtained from fifty-five participants aged ≥ 20 years (mean age: 65.1 years, 78.2% women). To exclude a systematic difference between the two methods, we conducted a validation study for HBP and ABP in another population that consisted of hypertensive outpatients (mean age: 65.4 years, 53.4% women). Results After adjusting for the systematic difference in BP between the two methods calculated in the validation study (3.9 mmHg for systolic and 3.0 mmHg for diastolic), morning and daytime (average of morning and evening) HBP were significantly lower than morning (average of 2 h after waking) and daytime (average of being awake) ABP, respectively. No significant difference was found in nocturnal BP between HBP and ABP monitoring regardless of the quality of sleep during nocturnal HBP measurement. Agreement between HBP and ABP in the detection of non-dippers was low mainly due to the difference in daytime BP values. Conclusio…

Integrity signals

Registry

Crossref · 10.1080/10641963.2020.1779281

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hosohata, K., Kikuya, M., Asayama, K., Metoki, H., Imai, Y., & Ohkubo, T.
Affiliations
  • Osaka University of Pharmaceutical Sciences (JP)
  • Teikyo University (JP)
  • Tohoku Medical and Pharmaceutical University (JP)
  • Tohoku Institute for Management of Blood Pressure (JP)
Corresponding author
Ohkubo, Takayoshi
Venue
Clinical and Experimental Hypertension
Published
2020-06-11
Volume
42
Issue
8
Pages
685-691
ISSN
  • 0148-3927 (ISSN-L)
  • 1064-1963
  • 1525-6006
OpenAlex
W3033117275
Cited by
16
References
38
Citations by year
2026: 1 · 2025: 4 · 2024: 5 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 2
FWCI
0.93
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • Clinical and Experimental Hypertension (publishedVersion)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
  • Lirias (submittedVersion, other-oa)
Funders
Comprehensive Research on Cardiovascular and Life-Style Related
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
nocturnal blood pressure, home blood pressure monitoring, ambulatory blood pressure monitoring, non-dippers, nocturnal blood pressure dipping, measurement agreement, hypertension, hypertensive target organ damage, sleep quality, Ohasama study
MeSH terms
Aged, Blood Pressure, Blood Pressure Determination, Female, Humans, Hypertension, Male, Middle Aged, Outpatients, Sleep, Prevalence, Blood Pressure Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review