CoChat

Perfluorocarbon-based Oxygen Delivery

Open access
Riess, Jean G. · 2006 · Artificial Cells, Blood Substitutes, and Biotechnology
Cited by 233

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

The basic properties of perfluorocarbons (PFCs) and PFC emulsions relevant to their use as oxygen delivery systems are briefly reviewed. The key issues related to the selection of an appropriate, readily excretable PFC and the engineering of a stable injectable PFC emulsion are discussed. Oxygent, a terminally heat-sterilized, injectable 60% w/v PFC emulsion made primarily of F-octyl bromide and a few percent of F-decyl bromide, with egg phospholipids as an emulsifier, has been developed. Its efficacy in avoiding and reducing red cell transfusion during surgery has been established during a Phase III clinical evaluation. Another Phase III clinical trial in cardiopulmonary bypass surgery, with a protocol that included both augmented-acute normovolemic hemodilution and intraoperative autologous donation, has, however, been interrupted following the observation of adverse events. Data analysis assigned these events to an inappropriate study protocol. A search for possible interactions between Oxygent and fluids present during cardiopulmonary bypass surgery detected no effect of the emulsion on hemostasis, hemolysis and blood rheology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10731190600973824

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 233

Metadata

Authors
Riess, J. G.
Venue
Artificial Cells, Blood Substitutes, and Biotechnology
Published
2006-01
Volume
34
Issue
6
Pages
567-580
ISSN
  • 1055-7172 (ISSN-L)
  • 1073-1199
  • 1532-4184
OpenAlex
W2095416951
Cited by
233
References
10
FWCI
3.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.