Theoretical Models of Microvascular Oxygen Transport to Tissue
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
To improve understanding of microvascular O 2 transport, theoretical modeling has been pursued for many years. The large number of studies in this area attests to the complexities (i.e., biochemical, structural, and hemodynamic) involved. This article focuses on theoretical studies from the last two decades and, in particular, on models of O 2 transport to tissue by discrete microvessels. A brief discussion of intravascular O 2 transport is first given, highlighting the physiological importance of intravascular resistance to blood‐tissue O 2 transfer. This is followed by a description of the Krogh tissue cylinder model of O 2 transport by a single capillary, which is shown to remain relevant in modified forms that relax many of the original biophysical assumptions. However, there are many geometric and hemodynamic complexities that require the consideration of microvascular arrays and networks. Multivessel models are discussed that have shown the physiological importance of heterogeneities in vessel spacing, O 2 supply, red blood cell flow path, as well as interactions between capillaries and arterioles. These realistic models require sophisticated methods for solving the governing partial differential equations, and a range of solution techniques are described. Finally, the issue of experimental validation of microvascular O 2 delivery models is discussed, and new directions in O 2 transport modeling are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krogh, A. (1919) · The Journal of Physiology · doi:10.1113/jphysiol.1919.sp001839 · Cited by 1,426 · cited 3×
“Inspired by the structure of skeletal muscle, with its parallel muscle fibers and capillaries, Krogh [49] originated the idea of representing the O2 transport in an entire microvascular bed by a single capillary that supplies O2 to the cylinder of tissue surrounding it.”
BackgroundInfluentialThe biological lifetime of nitric oxide: Implications for the perivascular dynamics of NO and O 2
Thomas, D. D., Liu, X., Kantrow, S. P., & Lancaster, J. R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.1.355 · Cited by 760 · cited 1×
“, O2-dependent production and consumption of NO [53,84]).”
BackgroundBlood flow in microvascular networks. Experiments and simulation.
Pries, A. R., Secomb, T. W., Gaehtgens, P., & Gross, J. F. (1990) · Circulation Research · doi:10.1161/01.res.67.4.826 · Cited by 566 · cited 1×
“This model, which also included a two-phase simulation of network blood flow (based on [68]),”
MethodTheory of oxygen transport to tissue.
Popel, A. S. (1989) · PubMed · Cited by 406
Effect of a maldistribution of microvascular blood flow on capillary O2 extraction in sepsis
Ellis, C. G., Bateman, R. M., Sharpe, M. D., Sibbald, W. J., & Gill, R. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2002.282.1.h156 · Cited by 278
Federspiel, W. J., & Popel, A. S. (1986) · Microvascular Research · doi:10.1016/0026-2862(86)90052-x · Cited by 262 · cited 5×
“Following earlier work [34], Federspiel and Popel [18] considered stationary spherical RBCs arranged in single file with a full description of diffusion of free and Hb-bound O2 inside the RBCs, the kinetics of Hb-O2 binding, and diffusion of O2 in the surrounding plasma.”
BackgroundInfluentialGreen's Function Methods for Analysis of Oxygen Delivery to Tissue by Microvascular Networks
Secomb, T. W., Hsu, R., Park, E. Y. H., & Dewhirst, M. W. (2004) · Annals of Biomedical Engineering · doi:10.1114/b:abme.0000049036.08817.44 · Cited by 238 · cited 1×
“A review and extension of the above Green’s function method was given in [77].”
MethodMicrovascular and tissue oxygen gradients in the rat mesentery
Tsai, A. G., Friesenecker, B., Mazzoni, M. C., Kerger, H., Buerk, D. G., Johnson, P. C., & Intaglietta, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.12.6590 · Cited by 230 · cited 1×
“[86] proposed that extremely high arteriolar wall O2 consumption (see discussion of their methods in [26]) was causing the discrepancy between theory and experiment, but an analysis of available data based on the O2 diffusion and consumption properties of the wall [89] concluded that O2 fluxes had been overestimated,…”
BackgroundAnalysis of oxygen transport to tumor tissue by microvascular networks
Secomb, T. W., Hsu, R., Dewhirst, M. W., Klitzman, B., & Gross, J. F. (1993) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(93)90070-c · Cited by 204 · cited 1×
“This model was extended to include variable O2 consumption (using an iterative procedure) and used to study O2 transport in mammary adenocarcinoma tumors [76].”
MethodGOLDMAN, D., & POPEL, A. S. (2000) · Journal of Theoretical Biology · doi:10.1006/jtbi.2000.2113 · Cited by 203 · cited 6×
“Following earlier work [34], Federspiel and Popel [18] considered stationary spherical RBCs arranged in single file with a full description of diffusion of free and Hb-bound O2 inside the RBCs, the kinetics of Hb-O2 binding, and diffusion of O2 in the surrounding plasma.”
BackgroundMethodInfluentialSelf-citationIntravital imaging of tumour vascular networks using multi-photon fluorescence microscopy
TOZER, G. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.07.015 · Cited by 163 · cited 1×
“by Pittman [64]; however, a combination of existing and emerging techniques [1,26,43,81,85,90] shows promise for supporting further theoretical advances based on the development and validation of realistic models of in vivo O2 transport.”
BackgroundSimulation of intraluminal gas transport processes in the microcirculation
Hellums, J. D., Nair, P. K., Huang, N. S., & Ohshima, N. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02770991 · Cited by 150 · cited 4×
“This article begins with a brief discussion of intraerythrocyte and intravascular O2 transport [65,34], including factors that determine intravascular resistance to blood-tissue O2 transport.”
BackgroundInfluentialO2 gradients from sarcolemma to cell interior in red muscle at maximal VO2
Gayeski, T. E., & Honig, C. R. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.251.4.h789 · Cited by 141 · cited 1×
“surements of PO2 (based on Mb saturation) in working muscle available at the time [21].”
BackgroundModeling Advection and Diffusion of Oxygen in Complex Vascular Networks
Beard, D. A., & Bassingthwaighte, J. B. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1359450 · Cited by 123 · cited 4×
“Beard and Bassingthwaighte [4] presented a network model of the heart that used 16 parallel capillaries on a hexagonal grid with 160 random cross-connections and included 3D diffusion, Mb facilitation, and Michaelis-Menten consumption.”
BackgroundMethodInfluentialEllsworth, M. L., Popel, A. S., & Pittman, R. N. (1988) · Microvascular Research · doi:10.1016/0026-2862(88)90089-1 · Cited by 119 · cited 2×
“Note that heavily working muscle is the case for which the Krogh geometry remains most relevant, since capillary transport is most dominant and parallel capillaries have the least diffusive interaction [17,74], as discussed below.”
BackgroundA theoretical model for oxygen transport in skeletal muscle under conditions of high oxygen demand
McGuire, B. J., & Secomb, T. W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.5.2255 · Cited by 117 · cited 6×
“Hsu and Secomb [40] presented a steady-state model of O2 transport in capillary networks and surrounding tissue based on the Green’s function method.”
BackgroundMethodInfluentialGoldman, D., Bateman, R. M., & Ellis, C. G. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00547.2005 · Cited by 115 · cited 1×
“In a subsequent study [22], the baseline model for O2 transport during sepsis was considered for decreasing O2 supply.”
BackgroundSelf-citationThe rate of oxygen release and its effect on capillary O2 tension: A mathematical analysis
Gutiérrez, G. (1986) · Respiration Physiology · doi:10.1016/0034-5687(86)90032-0 · Cited by 110 · cited 1×
“Similar previous work using a homogeneous description of blood [33,79] indicated that including Hb-O2 kinetics lowers end-capillary plasma and tissue PO2 compared to the equilibrium case, particularly for hypoxia and anemia.”
A Computational Study of the Effect of Vasomotion on Oxygen Transport from Capillary Networks
Goldman, D., & Popel, A. S. (2001) · Journal of Theoretical Biology · doi:10.1006/jtbi.2000.2254 · Cited by 108 · cited 1×
“The same model was used to study capillary network O2 transport during oscillatory blood flow or vasomotion [25].”
MethodSelf-citationGoldman, D., Bateman, R. M., & Ellis, C. G. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00889.2003 · Cited by 101 · cited 2×
“[23] used parallel arrays in a network transport model ([24], see below) to analyze experimental data on capillary hemodynamics and SO2 in rat skeletal muscle during sepsis [15].”
MethodSelf-citationOxygen Transport and Exchange in the Microcirculation
PITTMAN, R. N. (2005) · Microcirculation · doi:10.1080/10739680590895064 · Cited by 97 · cited 3×
“tally [64], theoretical modeling has been used to”
BackgroundMethodEffect of hemodilution on oxygen transport in arteriolar networks of hamster striated muscle
Kuo, L., & Pittman, R. N. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.2.h331 · Cited by 90 · cited 2×
“To explore experimental data on longitudinal PO2 gradients in arterioles [50] that suggested the O2 permeability of blood-perfused tissue was much greater than expected [67], Weerappuli and Popel Figure 5.”
BackgroundResultRate of oxygen loss from arterioles is an order of magnitude higher than expected
Popel, A. S., Pittman, R. N., & Ellsworth, M. L. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.256.3.h921 · Cited by 90
Beard, D. A. (2006) · PLoS Computational Biology · doi:10.1371/journal.pcbi.0020107 · Cited by 84 · cited 1×
“One important area of current theoretical modeling of the microcirculation involves multiscale models that couple details of O2 transport to related biological processes (such as angiogenesis [56] and metabolism [3]) occurring at similar and smaller scales.”
BackgroundAnalysis of phosphorescence in heterogeneous systems using distributions of quencher concentration
Golub, A. S., Popel, A. S., Zheng, L., & Pittman, R. N. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78084-6 · Cited by 81 · cited 1×
“Therefore, intravital videomicroscopy [43] has been the principal technique used, although it, too, has limitations in terms of the depth at which measurements can be made (typicallyB100 mm), the amount of 3D information that can be obtained, its temporal resolution (and, hence, maximum RBC velocity as well as minimum…”
MethodEstimating oxygen transport resistance of the microvascular wall
Vadapalli, A., Pittman, R. N., & Popel, A. S. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.2.h657 · Cited by 80 · cited 1×
“[86] proposed that extremely high arteriolar wall O2 consumption (see discussion of their methods in [26]) was causing the discrepancy between theory and experiment, but an analysis of available data based on the O2 diffusion and consumption properties of the wall [89] concluded that O2 fluxes had been overestimated,…”
BackgroundSimultaneous Blood–Tissue Exchange of Oxygen, Carbon Dioxide, Bicarbonate, and Hydrogen Ion
Dash, R. K., & Bassingthwaighte, J. B. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9066-4 · Cited by 76 · cited 3×
“Beard and Bassingthwaighte [4] presented a network model of the heart that used 16 parallel capillaries on a hexagonal grid with 160 random cross-connections and included 3D diffusion, Mb facilitation, and Michaelis-Menten consumption.”
MethodRadial and longitudinal diffusion of myoglobin in single living heart and skeletal muscle cells
Papadopoulos, S., Endeward, V., Revesz-Walker, B., Jürgens, K. D., & Gros, G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.101109798 · Cited by 75 · cited 1×
“Mb diffusion appears to be isotropic in heart and skeletal muscle cells [62] with DMb:8 10 (7)cm(2)/s in heart at 408C [55].”
BackgroundDetermination of red blood cell oxygenation in vivo by dual video densitometric image analysis
Ellis, C. G., Ellsworth, M. L., & Pittman, R. N. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.258.4.h1216 · Cited by 69 · cited 1×
“Therefore, intravital videomicroscopy [43] has been the principal technique used, although it, too, has limitations in terms of the depth at which measurements can be made (typicallyB100 mm), the amount of 3D information that can be obtained, its temporal resolution (and, hence, maximum RBC velocity as well as minimum…”
MethodPrediction of oxygen transport rates in blood flowing in large capillaries
Nair, P. K., Hellums, J. D., & Olson, J. S. (1989) · Microvascular Research · doi:10.1016/0026-2862(89)90005-8 · Cited by 67 · cited 2×
“[59] developed a theoretical model of intravascular O2 transport and validated it against experimental data.”
BackgroundInteractions between NO and O2 in the microcirculation: a mathematical analysis
Lamkin-Kennard, K. A., Buerk, D. G., & Jaron, D. (2004) · Microvascular Research · doi:10.1016/j.mvr.2004.03.001 · Cited by 66 · cited 3×
“Other species can also affect O2 transport itself; for example, by competing with O2 for binding to Hb (as does CO), by shifting the HbO2 saturation curve (as discussed below for CO2), and by inhibiting mitochondrial O2 consumption (as does NO [53]).”
BackgroundMethodEstimation of capillary density in human skeletal muscle based on maximal oxygen consumption rates
McGuire, B. J., & Secomb, T. W. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00559.2003 · Cited by 66 · cited 5×
“Hsu and Secomb [40] presented a steady-state model of O2 transport in capillary networks and surrounding tissue based on the Green’s function method.”
BackgroundMethodInfluentialPrediction of Microcirculatory Oxygen Transport by Erythrocyte/Hemoglobin Solution Mixtures
Page, T. C., Light, W. R., & Hellums, J. D. (1998) · Microvascular Research · doi:10.1006/mvre.1998.2088 · Cited by 65
Beard, D. A., Schenkman, K. A., & Feigl, E. O. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00380.2003 · Cited by 64
Ji, J. W., Tsoukias, N. M., Goldman, D., & Popel, A. S. (2006) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.11.019 · Cited by 63 · cited 2×
“Single and multiple microvascular units have been considered in O2 transport studies of angiogenesis [44] and Hb-based blood substitutes [87].”
BackgroundSelf-citationGroebe, K. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80300-0 · Cited by 62
Mathematical model of oxygen transport in the cerebral cortex
Hudetz, A. G. (1999) · Brain Research · doi:10.1016/s0006-8993(98)01200-1 · Cited by 60 · cited 1×
“Hudetz [42] studied O2 transport in the cerebral cortex by using the standard Krogh model but with a conical tissue cylinder that tapered toward the venous end of the capillary.”
MethodA Model of NO/O2 Transport in Capillary-perfused Tissue Containing an Arteriole and Venule Pair
Chen, X., Buerk, D. G., Barbee, K. A., & Jaron, D. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9236-z · Cited by 58 · cited 2×
“[9] used a steady-state 3D model to study coupled NO/O2 transport in an arteriole/venule pair surrounded by capillary-perfused tissue, which was modeled as a porous medium that connected the larger vessels by both diffusion and convection.”
BackgroundMethodRole of geometry and anisotropic diffusion for modelling PO2 profiles in working red muscle
Groebe, K., & Thews, G. (1990) · Respiration Physiology · doi:10.1016/0034-5687(90)90131-h · Cited by 57 · cited 5×
“Groebe and Thews [31] used a finite-difference method to study O2 transport from moving cylindrical RBCs (without plasma convection) in heavily working muscle for O2 flux and PO2 boundary conditions at the wall.”
BackgroundResultInfluentialNonlinear model for capillary-tissue oxygen transport and metabolism
Li, Z., Yipintsoi, T., & Bassingthwaighte, J. B. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684839 · Cited by 54 · cited 4×
“Transport of other species can be important as a means of studying O2 transport [54] or because of the effect of O2 on the other species (e.”
BackgroundMethodInfluentialTsoukias, N. M., Goldman, D., Vadapalli, A., Pittman, R. N., & Popel, A. S. (2007) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2007.06.012 · Cited by 53 · cited 2×
“Single and multiple microvascular units have been considered in O2 transport studies of angiogenesis [44] and Hb-based blood substitutes [87].”
BackgroundMethodSelf-citationMulti-scale Computational Models of Pro-angiogenic Treatments in Peripheral Arterial Disease
Gabhann, F. M., Ji, J. W., & Popel, A. S. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9303-0 · Cited by 49
P o 2 profiles near arterioles and tissue oxygen consumption in rat mesentery
Golub, A. S., Barker, M. C., & Pittman, R. N. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00077.2007 · Cited by 47 · cited 3×
“Therefore, intravital videomicroscopy [43] has been the principal technique used, although it, too, has limitations in terms of the depth at which measurements can be made (typicallyB100 mm), the amount of 3D information that can be obtained, its temporal resolution (and, hence, maximum RBC velocity as well as minimum…”
BackgroundMethodLin, P., Kreutzer, U., & Jue, T. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.094458 · Cited by 44 · cited 1×
“Mb diffusion appears to be isotropic in heart and skeletal muscle cells [62] with DMb:8 10 (7)cm(2)/s in heart at 408C [55].”
BackgroundKirkpatrick, J. P., Brizel, D. M., & Dewhirst, M. W. (2003) · Radiation Research · doi:10.1667/0033-7587(2003)159[0336:ammoto]2.0.co;2 · Cited by 41 · cited 1×
“[47] used a Krogh-type model to study O2 and glucose transport in tumors.”
MethodDetermination of myoglobin saturation of frozen specimens using a reflecting cryospectrophotometer
Voter, W. A., & Gayeski, T. E. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.4.h1328 · Cited by 40 · cited 1×
“B4 mm, while the mean muscle fiber radius was 45 mm [91].”
BackgroundStyp‐Rekowska, B., Disassa, N. M., Reglin, B., Ulm, L., Kuppe, H., Secomb, T. W., & Pries, A. R. (2007) · Microcirculation · doi:10.1080/10739680601139302 · Cited by 38 · cited 1×
“by Pittman [64]; however, a combination of existing and emerging techniques [1,26,43,81,85,90] shows promise for supporting further theoretical advances based on the development and validation of realistic models of in vivo O2 transport.”
BackgroundSullivan, J. P., Gordon, J. E., & Palmer, A. F. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20673 · Cited by 35 · cited 1×
“[82] are not considered, and the focus is on tissue O2 transport in skeletal muscle, heart, brain, and Address correspondence to Daniel Goldman, Department of Medical Biophysics, 491 Medical Sciences Building, The University of Western Ontario, London, Ontario, N6A 5C1, Canada.”
BackgroundEffect of hemodilution on oxygen transport in arteriolar networks of hamster striated muscle
Kuo, L., & Pittman, R. N. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.1.1-b · Cited by 30
Diffusion limitation of O2 supply to tissue in homogeneous and heterogeneous models
Piiper, J., & Scheid, P. (1991) · Respiration Physiology · doi:10.1016/0034-5687(91)90011-7 · Cited by 30 · cited 1×
“Using Krogh and Hill (uniform O2 supply on exterior of tissue cylinder) models, Piiper and Scheid [63] performed a similar study, and showed that if multiple size tissue cylinders were considered (simulated supply heterogeneity), diffusion limitation began at a lower O2 supply than in a single cylinder with the same a…”
MethodEffect of heterogeneous oxygen delivery on the oxygen distribution in skeletal muscle
Popel, A. S., Charny, C. K., & Dvinsky, A. (1986) · Mathematical Biosciences · doi:10.1016/0025-5564(86)90164-1 · Cited by 29 · cited 2×
“extension of the model [66] to study heterogeneity”
MethodVarghese, H. J., MacKenzie, L. T., Groom, A. C., Ellis, C. G., Chambers, A. F., & MacDonald, I. C. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01022.2003 · Cited by 26 · cited 1×
“by Pittman [64]; however, a combination of existing and emerging techniques [1,26,43,81,85,90] shows promise for supporting further theoretical advances based on the development and validation of realistic models of in vivo O2 transport.”
BackgroundA Model of NO/O2Transport in Capillary-perfused Tissue Containing an Arteriole and Venule Pair
Chen, X., Buerk, D. G., Barbee, K. A., & Jaron, D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616266 · Cited by 9
The Role of Counter-Current Exchange in Preventing Hypoxia in Skeletal Muscle
Teboh-Ewungkem, M. I., & Salathé, E. P. (2006) · Bulletin of Mathematical Biology · doi:10.1007/s11538-006-9102-z · Cited by 4 · cited 1×
“This model was later extended to include axial diffusion [70], as well as Mb facilitation and countercurrent flow [83].”
MethodUltra-Fast Biosensors and Multi-Photon Microscopy in the Future of Brain Studies
Bakalova, R. (2006) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-006-9129-6 · Cited by 2
Cited by
The capillary bed offers the largest hemodynamic resistance to the cortical blood supply
Gould, I. G., Tsai, P., Kleinfeld, D., & Linninger, A. (2017) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16671146 · Cited by 252
“0 Red Blood Cell Velocity, mm/s Cerebral Blood Perfusion*** mL/100g/min ● 78±16 (19-101) This Work 70-170 Xu(67) ● 142±57 Maeda(73) 40-65 Gertz(89) 0 40 80 120 160 200 Blood Perfusion, mL/100g/min Cerebral Oxygen Metabolism*** μmole/g/min ● 1.”
Sakadžić, S., Mandeville, E. T., Gagnon, L., Musacchia, J. J., Yaseen, M. A., Yucel, M. A., Lefebvre, J., Lesage, F., Dale, A. M., Eikermann-Haerter, K., et al. (2014) · Nature Communications · doi:10.1038/ncomms6734 · Cited by 183
Metadata
- Authors
- GOLDMAN, D.
- Venue
- Microcirculation
- Publisher
- Wiley
- Published
- 2008-11
- Volume
- 15
- Issue
- 8
- Pages
- 795-811
- ISSN
- 1073-9688 (ISSN-L)
- 1549-8719
- OpenAlex
- W2115146410
- Cited by
- 178
- References
- 55
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.