Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Background: Stroke-specific protocols for the 10-meter and 6-minute walk tests that include instructions for people with aphasia, accessible walkway lengths, and allow provision of assistance to walk are needed to facilitate uptake in hospital settings.Objectives: To estimate the test-retest reliability, measurement error, and construct validity of stroke-specific protocols for the 10-meter walk test (10mWT), and 6-minute walk test conducted using a 15-meter walkway (6MWT15m) and 30-meter walkway (6MWT30m), in people post-stroke.Methods: A quantitative, cross-sectional study involving ambulatory people post-stroke was conducted.Results: Data were collected from 21 and 20 participants at baseline and retest, respectively, 1–3 days apart. Mean age was 61 years, median time post-stroke was 134 days, and 90% had experienced an ischemic stroke. Performance on the 10mWT, 6MWT15m, and 6MWT30m across sessions yielded intraclass correlation coefficient (ICC2, 1) estimates of test-retest reliability of 0.83, 0.97, 0.95, respectively, and minimal detectable change values at the 95% confidence level of 0.40m/s, 44.0m, and 67.5m, respectively. Pearson correlation coefficients were 0.80–0.95 (p < .001) between results on all three walk tests and 0.27–0.48 (p < .25) between walk test results and strength subscale scores on the Stroke Impact Scale.Conclusions: Findings showed excellent test-retest reliability; measurement error values similar to current literature; and support for construct validity of the 10mWT, 6MWT15m, and 6MWT30m. Due to the shorter walkway, the 6MWT15m may be more feasible to implement than the 6MWT30m in hospital settings. A larger sample with more severe deficits is required to improve generalizability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Health Measurement Scales: A Practical Guide to Their Development and Use
Streiner, D. L., Norman, G. R., & Cairney, J. (1989) · Cited by 9,595
Health Measurement Scales: A practical guide to their development and use
Streiner, D. L., Norman, G. R., & Cairney, J. (2014) · doi:10.1093/med/9780199685219.001.0001 · Cited by 2,564
Holland, A. E., Spruit, M. A., Troosters, T., Puhan, M. A., Pepin, V., Saey, D., McCormack, M. C., Carlin, B. W., Sciurba, F. C., Pitta, F., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00150314 · Cited by 2,530 · cited 3×
“Third, recommended protocols for administering both tests lack applicability to the stroke population as they do not allow for physical assistance from the evaluator during walking and do not include instructions for use with patients with aphasia.(10,39) Lastly, clinical use of the 6MWT has been limited by recommenda…”
BackgroundMethodTwo-, six-, and 12-minute walking tests in respiratory disease.
Butland, R. J., Pang, J., Gross, E. R., Woodcock, A. A., & Geddes, D. M. (1982) · BMJ · doi:10.1136/bmj.284.6329.1607 · Cited by 1,668
RELIABILITY OF GAIT PERFORMANCE TESTS IN MEN AND WOMEN WITH HEMIPARESIS AFTER STROKE
Lexell, J., Flansbjer, U.-B., Holmbäck, A. M., Downham, D., & Patten, C. (2005) · Journal of Rehabilitation Medicine · doi:10.1080/16501970410017215 · Cited by 1,242 · cited 1×
“For test-retest reliability, the lower limit of the 95% CI of the ICC for the 10mWT was adequate and lower than in previous studies that evaluated chronic stroke populations.(15,16) The inclusion of people with acute and subacute stroke in this study may explain this difference, as later phases of stroke recovery are…”
The Stroke Impact Scale Version 2.0: Evaluation of Reliability, Validity, and Sensitivity to Change
Duncan, P. W., Wallace, D., Lai, S. M., Johnson, D., Embretson, S., & Laster, L. J. (1999) · Stroke · doi:10.1161/01.str.30.10.2131 · Cited by 1,180 · cited 1×
“The sum of item scores is transformed to a total score out of 100, with higher scores indicating greater strength.(30) A 7-point scale adapted from the FIM locomotion scale(46) was used to rate the level of independence to walk.”
MethodRecovery of walking function in stroke patients: The copenhagen stroke study
Jørgensen, H. S., Nakayama, H., Raaschou, H. O., & Olsen, T. S. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80038-7 · Cited by 1,164 · cited 1×
“Two thirds of people affected by stroke have limited walking ability, and half are unable to walk even with physical assistance within one month post-stroke.(1) Thus, assessment and improvement in walking ability is a key objective in stroke rehabilitation(2,3) especially in the first several weeks post-stroke.”
BackgroundManagement of Adult Stroke Rehabilitation Care: A Clinical Practice Guideline
Duncan, P. W., Zorowitz, R., Bates, B., Choi, J. Y., Glasberg, J. J., Graham, G. D., Katz, R. C., Lamberty, K., & Reker, D. (2005) · Stroke · doi:10.1161/01.str.0000180861.54180.ff · Cited by 1,046
Metadata
- Authors
- Cheng, D. K., Nelson, M., Brooks, D., & Salbach, N. M.
- Venue
- Topics in Stroke Rehabilitation
- Publisher
- Informa UK Limited
- Published
- 2019-11-21
- Volume
- 27
- Issue
- 4
- Pages
- 251-261
- ISSN
- 1074-9357 (ISSN-L)
- 1945-5119
- OpenAlex
- W2991241581
- Cited by
- 162
- References
- 56
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways. https://app.cochat.ai/papers/10.1080/10749357.2019.1691815
- The paper
- Cheng, D. K., Nelson, M., Brooks, D., & Salbach, N. M. (2020). Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways. Topics in Stroke Rehabilitation. https://doi.org/10.1080/10749357.2019.1691815
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.