CoChat

qSOFA Has Poor Sensitivity for Prehospital Identification of Severe Sepsis and Septic Shock

Dorsett, Maia, Kroll, Melissa, Smith, Clark S., Asaro, Phillip, Liang, Stephen Y., Moy, Hawnwan P. · 2017 · Prehospital Emergency Care
Cited by 119

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Sepsis is a common and deadly disease process for which early recognition and intervention can significantly improve clinical outcomes. Despite this, sepsis remains underrecognized and therefore undertreated in the prehospital setting. Recent recommendations by the Society of Critical Care and European Society of Intensive Care Medicine advocate use of the qSOFA (quick Sequential [Sepsis-related] Organ Failure Assessment) score in non-ICU settings to screen for septic patients at greater risk for poor outcomes. METHODS: We retrospectively evaluated the sensitivity and specificity of a prehospital qSOFA score ≥ 2 for prehospital identification of patients with severe sepsis or septic shock. Emergency Department (ED) patients with confirmed or suspected infection were classified as having infection without sepsis (n = 71), sepsis (n = 38), or severe sepsis/septic shock (n = 43), where designation of severe sepsis/septic shock required evidence of end-organ dysfunction, hypoperfusion (lactate > 2), or vasopressor requirement. RESULTS: We found that a prehospital qSOFA score ≥ 2 was 16.3% sensitive (95% CI 6.8-30.7%) and 97.3% specific (95% CI 92.1-99.4%) for patients ultimately confirmed to have severe sepsis/septic shock in the ED. Adding an additional point to the prehospital qSOFA score for a pulse > 100, nursing home residence, age > 50, or reported fever increased the sensitivity to 58.1% (95% CI 42.1-73.0%) and decreased the specificity to 78.0% (95% CI 69.0-85.4%). During their ED stay, approximately two-thirds of patients meeting severe sepsis/septic shock criteria eventually met qSOFA criteria with a sensitivity of 67.4% (95% CI 51.5-80.9) and specificity of 86.2% (95% CI 78.3-92). Failure to meet qSOFA criteria prehospital was predominantly due to a systolic blood pressure and respiratory rate that did not yet meet predetermined thresholds. CONCLUSIONS: These findings suggest that the dynamic nature of sepsis can make sensitive detection difficult in the prehospital setting, although combining qSOFA with other clinical information (age, nursing home status, fever, and tachycardia) can identify more patients with sepsis who may benefit from time critical interventions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10903127.2016.1274348

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 119

Metadata

Authors
Dorsett, M., Kroll, M., Smith, C. S., Asaro, P., Liang, S. Y., & Moy, H. P.
Venue
Prehospital Emergency Care
Published
2017-01-25
Volume
21
Issue
4
Pages
489-497
ISSN
  • 1090-3127 (ISSN-L)
  • 1545-0066
OpenAlex
W2580335324
Cited by
119
References
10
FWCI
12.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: qSOFA Has Poor Sensitivity for Prehospital Identification of Severe Sepsis and Septic Shock. https://app.cochat.ai/papers/10.1080/10903127.2016.1274348
The paper
Dorsett, M., Kroll, M., Smith, C. S., Asaro, P., Liang, S. Y., & Moy, H. P. (2017). qSOFA Has Poor Sensitivity for Prehospital Identification of Severe Sepsis and Septic Shock. Prehospital Emergency Care. https://doi.org/10.1080/10903127.2016.1274348

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.