CoChat

The bioartificial liver: state-of-the-art

Dixit, Vivek, Gitnick, Gary · 2003 · European Journal of Surgery
Cited by 50

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The rationale for artificial liver support is based on the hypothesis that if essential liver functions can be restored during the critical phase of liver failure, it should be possible to improve the survival of patients with severe liver disease. In the case of bridge-to-transplantation, it should provide the patient sufficient metabolic support until a donor liver can be found and transplanted. Since the management of acute liver failure requires the replacement of the liver's myriad metabolic functions, the idea of a hybrid bioartificial liver (BAL) support system has been proposed. BAL systems incorporate a biological (hepatocytes) and a synthetic housing component (plastic housing shell and semipermeable membrane) coupled in such a way as to facilitate the delivery of essential liver functions. Of the several BAL designs that have been proposed, only the capillary hollow-fiber based systems have been rapidly developed for clinical trials. Capillary hollow-fiber based BAL devices are basically off-the-shelf artificial kidney membranes that have been modified for use as an artificial liver. However, most capillary hollow-fiber based BAL designs have inherent physical limitations of total diffusion surface area and capacity for hepatocyte mass. We have proposed a novel BAL design using microencapsulated hepatocytes to overcome these physical limitations. This new BAL design (UCLA-BAL) involves the direct hemoperfusion of a packed-bed column of microencapsulated porcine hepatocytes within an extracorporeal chamber. In extensive animal studies using a well-characterized animal model fulminant hepatic failure (FHF), we demonstrated that the UCLA-BAL system had superior diffusion surface area and a higher capacity for hepatocytes compared to conventional capillary hollow-fiber based BAL devices. UCLA-BAL treatment significantly (P<0.001), improved the survival rate of FHF animals and significantly (P<0.01) prolonged the survival time of similar animals with very severe liver injury. BAL treatment was convenient, easy to operate and well tolerated, and did not adversely affect the animal's hemodynamics during treatment. We therefore suggest that the UCLA-BAL is a significant improvement over conventional, first-generation, capillary hollow-fiber BAL systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/11024159850191481

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 50

Metadata

Authors
Dixit, V., & Gitnick, G.
Venue
European Journal of Surgery
Published
2003-11-27
Volume
164
Issue
S12
Pages
71-76
ISSN
  • 1102-4151 (ISSN-L)
  • 1741-9271
OpenAlex
W2083117204
Cited by
50
References
1
FWCI
3.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The bioartificial liver: state-of-the-art. https://app.cochat.ai/papers/10.1080/11024159850191481
The paper
Dixit, V., & Gitnick, G. (2003). The bioartificial liver: state-of-the-art. European Journal of Surgery. https://doi.org/10.1080/11024159850191481

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.