ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot‐supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end‐effector‐based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503
An organizing principle for a class of voluntary movements
Hogan, N. (1984) · The Journal of Neuroscience · doi:10.1523/jneurosci.04-11-02745.1984 · Cited by 1,330
Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial
Kwakkel, G., Wagenaar, R. C., Twisk, J. W., Lankhorst, G. J., & Koetsier, J. C. (1999) · The Lancet · doi:10.1016/s0140-6736(98)09477-x · Cited by 938
Prange, G. B., Jannink, M. J. A., Groothuis-Oudshoorn, C. G. M., Hermens, H. J., & IJzerman, M. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0076 · Cited by 917
Bütefisch, C., Hummelsheim, H., Denzler, P., & Mauritz, K.-H. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00003-k · Cited by 840
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Self-citationDynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study
Karduna, A. R., McClure, P. W., Michener, L. A., & Sennett, B. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1351892 · Cited by 622
Reinkensmeyer, D. J., Kahn, L. E., Averbuch, M., McKenna-Cole, A. N., Schmit, B. D., & Rymer, W. Z. (2000) · PubMed · Cited by 558
Cited by
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
Klamroth-Marganska, V., Blanco, J., Campen, K., Curt, A., Dietz, V., Ettlin, T., Felder, M., Fellinghauer, B., Guidali, M., Kollmar, A., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70305-3 · Cited by 522
Self-citationDevelopments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation
Mao, Y., & Agrawal, S. K. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2189496 · Cited by 409
Kim, B., & Deshpande, A. D. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364917706743 · Cited by 309
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Crea, S., Beckerle, P., De Looze, M., De Pauw, K., Grazi, L., Kermavnar, T., Masood, J., O’Sullivan, L. W., Pacifico, I., Rodriguez-Guerrero, C., et al. (2021) · Wearable Technologies · doi:10.1017/wtc.2021.11 · Cited by 206
“…strategies should be included to counteract the effects of axis misalignments; whereas exoskeletons with nonanthropomorphic kinematic structures do not require a direct correspondence between the robot ’ s and user ’ s axes of rotation (Nef et al., 2009; Accoto et al., 2014).”
Sensors and Actuation Technologies in Exoskeletons: A Review
Tiboni, M., Borboni, A., Vérité, F., Bregoli, C., & Amici, C. (2022) · Sensors · doi:10.3390/s22030884 · Cited by 184
“[162], which adopts laser diodes to define the correct position of a subject using an upper limb exoskeleton.”
BackgroundInfluentialWang, X., Li, X., Wang, J., Fang, X., & Zhu, X. (2016) · Information Sciences · doi:10.1016/j.ins.2015.08.025 · Cited by 183
Babaiasl, M., Mahdioun, S. H., Jaryani, P., & Yazdani, M. (2015) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2014.1002539 · Cited by 182
“ARMin III [73–76] is a further improved version of ARMin II in the case of robustness, complexity, user operation and reliability.”
BackgroundA robotic system to train activities of daily living in a virtual environment
Guidali, M., Duschau-Wicke, A., Broggi, S., Klamroth-Marganska, V., Nef, T., & Riener, R. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0809-0 · Cited by 181
“To increase transparency and make the robot more compliant, gravity of the exoskeleton and the safety spring attached to the device have been modeled [29].”
BackgroundSelf-citationThe Present and Future of Robotic Technology in Rehabilitation
Laut, J., Porfiri, M., & Raghavan, P. (2016) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-016-0139-0 · Cited by 179
Human Movement Training With a Cable Driven ARm EXoskeleton (CAREX)
Mao, Y., Jin, X., Gera Dutta, G., Scholz, J. P., & Agrawal, S. K. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2329018 · Cited by 178
Veale, A. J., & Xie, S. Q. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.010 · Cited by 160
Näf, M. B., Junius, K., Rossini, M., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4042523 · Cited by 158
Metadata
- Authors
- Nef, T., Guidali, M., & Riener, R.
- Venue
- Applied Bionics and Biomechanics
- Publisher
- Wiley
- Published
- 2009-01
- Volume
- 6
- Issue
- 2
- Pages
- 127-142
- ISSN
- 1176-2322 (ISSN-L)
- 1754-2103
- OpenAlex
- W2096347511
- Cited by
- 522
- References
- 43
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.