Biosensors for biomarkers in medical diagnostics
Abstract
At present, most biomarker testing is taking place at centralised dedicated laboratories using large, automated analysers, increasing waiting time and costs. Smaller, faster and cheaper devices are highly desired for replacing these time-consuming laboratory analyses and for making analytical results available at the patient's bedside (point-of-care diagnostics). Innovative biosensor-based strategies could allow biomarkers to be tested reliably in a decentralised setting, although several challenges and limitations remain, which need to be improved, in the design and application of biosensors for the appropriate interpretation of the identified and quantified biomarkers. The development of biosensors is probably one of the most promising ways to solve some of the problems concerning the increasing need to develop highly sensitive, fast and economic methods of analysis in medical diagnostics. In this review, some consideration will be given to biosensors and their application in medical diagnostics, taking into account several crucial features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Stevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179
New Clinical Markers Predictive of Cardiovascular Disease: The Role of Inflammatory Mediators
Rackley, C. E. (2004) · Cardiology in Review · doi:10.1097/01.crd.0000126083.86717.5b · Cited by 14
Cited by
El-Husseiny, H. M., Mady, E. A., Hamabe, L., Abugomaa, A., Shimada, K., Yoshida, T., Tanaka, T., Yokoi, A., Elbadawy, M., & Tanaka, R. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100186 · Cited by 533
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Gupta, S., Hirota, M., Waugh, S. M., Murakami, I., Suzuki, T., Muraguchi, M., Shibamori, M., Ishikawa, Y., Jarvis, T. C., Carter, J. D., et al. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m113.532580 · Cited by 151
Theerthagiri, J., Lee, S. J., Karuppasamy, K., Park, J., Yu, Y., Kumari, M. L. A., Chandrasekaran, S., Kim, H.-S., & Choi, M. Y. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126648 · Cited by 85
Metadata
- Authors
- Mascini, M., & Tombelli, S.
- Venue
- Biomarkers
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 13
- Issue
- 7-8
- Pages
- 637-657
- ISSN
- 1354-750X (ISSN-L)
- 1366-5804
- OpenAlex
- W2095954866
- Cited by
- 220
- References
- 4
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biosensors for biomarkers in medical diagnostics. https://app.cochat.ai/papers/10.1080/13547500802645905
- The paper
- Mascini, M., & Tombelli, S. (2008). Biosensors for biomarkers in medical diagnostics. Biomarkers. https://doi.org/10.1080/13547500802645905
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.