The Concept and Design of Pleated Pneumatic Artificial Muscles
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This paper describes the design of a new type of Pneumatic Artificial Muscle (PAM), namely the Pleated Pneumatic Artificial Muscle (PPAM). It was developed as an improvement with regard to existing types of PAM, e.g. the McKibben muscle. Its principle characteristic is its pleated membrane. It can inflate without material stretching and friction and has practically no stress in the direction perpendicular to its axis of symmetry. Besides these it is extremely strong and yet very lightweight and it has a large stroke compared to most other designs. A general introduction on PAMs is given together with a short discussion and motivation for this new design. The concept of the PPAM is explained and a mathematical model is derived. This model proves its principle of operation. From the model, several characteristics, such as developed force, maximum contraction, diameter, volume and membrane tensile stress, are obtained. Material choices and dimensions of a typical PPAM are next discussed and its measured values of static force and diameter are compared to the model predicted values. The agreement between both is found to be very good.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2013 IEEE International Conference on Robotics and Automation
(2013) · doi:10.1109/icra19839.2013 · Cited by 2,025
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589 · cited 8×
“Total displacement or stroke, which is usually expressed as a percentage with regard to a reference length, ranges between 20% to 30% of the length at rest, see Chou and Hannaford (1996), Inoue (1987) and Tondu et al. (1995).”
BackgroundMethodInfluentialControl of pneumatic muscle actuators
(1995) · IEEE Control Systems · doi:10.1109/37.341863 · Cited by 468 · cited 4×
“This has an adverse effect on actuator behaviour and necessitates the use of complex actuator models and control, e.g. Tondu (1997) and Caldwell et al. (1995) .”
BackgroundMethodInfluentialThe characteristics of the McKibben artificial muscle
Schulte, H. F. J. (1961) · Medical Entomology and Zoology · Cited by 332
Application of rubber artificial muscle manipulator as a rehabilitation robot
Noritsugu, T., & Tanaka, T. (1997) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/3516.653050 · Cited by 243
Neural network control of a pneumatic robot arm
Hesselroth, T., Sarkar, K., van der Smagt, P., & Schulten, K. (1994) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/21.259683 · Cited by 157 · cited 2×
“41-50 Ever since their first conceiving, which the authors could trace back to a patent by Sensaud de Lavaud (1929), fluid-driven muscle-like actuators of a number of kinds have been developed.”
BackgroundMethodRubbertuators and applications for robots
Inoue, K. (1988) · International Symposium on Robotics · Cited by 121
Fatigue characteristics of McKibben artificial muscle actuators
Klute, G. K., & Hannaford, B. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.1998.724854 · Cited by 104 · cited 2×
“Klute and Hannaford (1998) describe rubber fatigue failure as the most common failure mode.”
BackgroundMethodThe anthroform biorobotic arm: A system for the study of spinal circuits
Hannaford, B., Winters, J. M., Chou, C.-P., & Marbot, P.-H. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584440 · Cited by 78
Realizable Models of Muscle Function
Baldwin, H. A. (1969) · Springer eBooks · doi:10.1007/978-1-4615-6558-1_14 · Cited by 59 · cited 7×
“According to Baldwin (1969), J. L. McKibben introduced this type of PAM as an orthotic actuator in the late 1950’s: due to the similarity in length–load curves between this artificial muscle and skeletal muscle, it seemed an ideal choice for this purpose, as stated by Schulte (1961). However, practical problems such a…”
MethodInfluentialGreenhill, S. (1993) · Industrial Robot the international journal of robotics research and application · doi:10.1108/eb004588 · Cited by 17 · cited 2×
“Greenhill (1993) , Hesselroth et al. (1994), Hannaford et al. (1995), Winters (1995), Noritsugu and Tanaka (1997), Tondu (1997), Caldwell et al. (1998) and Verrelst et al. (2000).”
MethodImmega, G. (1986) · Cited by 17
Analysis and Modeling of the Dynamic Behaviour of the McKibben Artificial Muscle
Tondu, B. (1997) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)44279-0 · Cited by 12 · cited 2×
“This has an adverse effect on actuator behaviour and necessitates the use of complex actuator models and control, e.g. Tondu (1997) and Caldwell et al. (1995).”
Method
Cited by
Fluid-driven origami-inspired artificial muscles
Li, S., Vogt, D. M., Rus, D., & Wood, R. J. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1713450114 · Cited by 747
Self-healing soft pneumatic robots
Terryn, S., Brancart, J., Lefeber, D., Van Assche, G., & Vanderborght, B. (2017) · Science Robotics · doi:10.1126/scirobotics.aan4268 · Cited by 537
Self-citationModelling of the McKibben artificial muscle: A review
Tondu, B. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x11435435 · Cited by 490
Pouch Motors: Printable Soft Actuators Integrated with Computational Design
Niiyama, R., Sun, X., Sung, C., An, B., Rus, D., & Kim, S. (2015) · Soft Robotics · doi:10.1089/soro.2014.0023 · Cited by 318
Textile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Metadata
- Authors
- Daerden, F., & Lefeber, D.
- Venue
- International Journal of Fluid Power
- Publisher
- River Publishers
- Published
- 2001-01
- Volume
- 2
- Issue
- 3
- Pages
- 41-50
- ISSN
- 1439-9776 (ISSN-L)
- 2332-1180
- OpenAlex
- W2006674054
- Cited by
- 237
- References
- 13
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.