CoChat

Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators

Oestenstad, Riedar Kent, Bartolucci, Alfred A. · 2010 · Journal of Occupational and Environmental Hygiene

The DOI matches its Crossref record, with a small difference in title or year; 17 of the 17 references it cites were found in a registry or an index.

Abstract

While there have been a number of studies on the effect of leak site and shape on the magnitude of measured leakage through respirator face seals, there have been very few studies to identify the location and size of these leaks. In a previous study we used a method of identifying the location and shape of respirator leaks on a half-mask respirator by the deposition of a fluorescent tracer during a fit test, and testing for their association with facial dimensions. The purpose of this study was to apply that methodology to conduct multiple fit tests to determine if gender, respirator brand, repeated fit tests, and test exercises affected the location and shape of face seal leak sites. Categorical analysis found that none of these factors had a significant effect on the location and shape of leaks. General linear model analysis found some significant effects of the study factors on leaks, but facial dimensions had a greater effect, and there were significant differences between facial dimensions of subjects with a leak and those without. Significant differences in leak site distributions between this and the previous study may have been due to differences in facial dimensions and racial/ethnic composition. Twice as many diffuse leaks as point leaks were observed in both studies, indicating that slit-like leaks would be most appropriate on mannequins used in laboratory respirator leakage studies, and in respirator flow and penetration models. That the study factors had no significant effects in the categorical analysis, significant effects for facial dimensions were found in the linear analysis, and leak site distribution differences between this and our previous study may have been affected by differences in facial dimensions, indicate that, in addition to size, the shape of an individual's face may be an important determinant of leak sites on a half-mask respirator. This would have implications for the design of respirator facepieces and in the selection of respirators for individual wearers.

Overview

Integrity signals

Registry

Crossref · 10.1080/15459621003729909

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Research works printed but not linked: 4

  1. Hinds W. C., 1987, Am. Ind. Hyg. J., 48, 158
  2. Held B. J., 1970, History of Respiratory Protective Devices in the US
  3. Cohen H. J., 1984, J. Int. Soc. Respir. Prot., 2, 305
  4. McClave J. T., 2006, Statistics,

Cited by

See all 54

Metadata

Authors
Oestenstad, R. K., & Bartolucci, A. A.
Affiliations
University of Alabama at Birmingham (US)
Venue
Journal of Occupational and Environmental Hygiene
Published
2010-04-08
Volume
7
Issue
6
Pages
332-341
ISSN
  • 1545-9624 (ISSN-L)
  • 1545-9632
OpenAlex
W2053309387
Cited by
54
References
17
Citations by year
2026: 1 · 2025: 4 · 2024: 8 · 2023: 7 · 2022: 7 · 2021: 11 · 2020: 1 · 2019: 1 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 4
FWCI
2.13
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Occupational and Environmental Hygiene (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute for Occupational Safety and Health (1K01OH00085)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
Keywords
half-mask respirators, facial dimensions, respirator fit testing, fluorescent tracers, gender differences, respirator selection
MeSH terms
Adult, Anthropometry, Equipment Design, Face, Female, Humans, Male, Middle Aged, Respiratory Protective Devices, Sex Factors, Equipment Failure Analysis, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators. https://app.cochat.ai/papers/10.1080/15459621003729909
The paper
Oestenstad, R. K., & Bartolucci, A. A. (2010). Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459621003729909

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.