Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators
The DOI matches its Crossref record, with a small difference in title or year; 17 of the 17 references it cites were found in a registry or an index.
Abstract
While there have been a number of studies on the effect of leak site and shape on the magnitude of measured leakage through respirator face seals, there have been very few studies to identify the location and size of these leaks. In a previous study we used a method of identifying the location and shape of respirator leaks on a half-mask respirator by the deposition of a fluorescent tracer during a fit test, and testing for their association with facial dimensions. The purpose of this study was to apply that methodology to conduct multiple fit tests to determine if gender, respirator brand, repeated fit tests, and test exercises affected the location and shape of face seal leak sites. Categorical analysis found that none of these factors had a significant effect on the location and shape of leaks. General linear model analysis found some significant effects of the study factors on leaks, but facial dimensions had a greater effect, and there were significant differences between facial dimensions of subjects with a leak and those without. Significant differences in leak site distributions between this and the previous study may have been due to differences in facial dimensions and racial/ethnic composition. Twice as many diffuse leaks as point leaks were observed in both studies, indicating that slit-like leaks would be most appropriate on mannequins used in laboratory respirator leakage studies, and in respirator flow and penetration models. That the study factors had no significant effects in the categorical analysis, significant effects for facial dimensions were found in the linear analysis, and leak site distribution differences between this and our previous study may have been affected by differences in facial dimensions, indicate that, in addition to size, the shape of an individual's face may be an important determinant of leak sites on a half-mask respirator. This would have implications for the design of respirator facepieces and in the selection of respirators for individual wearers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Some degree of leakage is expected around the edges of surgical and cloth masks in particular; poor mask fit and improper usage can further increase mask bypass, leading to a significant decrease in effectiveness [15,16,17].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [15]
Citations
Cites
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Handbook of Parametric and Nonparametric Statistical Procedures
Sheskin, D. J. (1996) · CRC Press eBooks · doi:10.4324/9780203489536 · Cited by 910
An aerosol generator of high stability
LIU, B. Y. H., & LEE, K. W. (1975) · American Industrial Hygiene Association Journal · doi:10.1080/0002889758507357 · Cited by 218
New respirator fit test panels representing the current U.S. civilian work force
Zhuang, Z., Bradtmiller, B., & Shaffer, R. E. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701497538 · Cited by 187
The National Institute for Occupational Safety and Health (NIOSH)
(2015) · Choice Reviews Online · doi:10.5860/choice.188912 · Cited by 169
OESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091369664 · Cited by 83
Self-citationCHARACTERISTICS OF FACE SEAL LEAKAGE IN FILTERING FACEPIECES
Chen, C. C., & Willeke, K. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360120 · Cited by 83
Measurer's Handbook: U.S. Army Anthropometric Survey, 1987-1988
Clauser, C. E., Tebbetts, I., Bradtmiller, B., et al. (1988) · doi:10.21236/ada202721 · Cited by 81
Performance of Dust Respirators with Facial Seal Leaks: I. Experimental
Hinds, W. C., & Kraske, G. K. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385679 · Cited by 70
(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meh097 · Cited by 50
Research works printed but not linked: 4
- Hinds W. C., 1987, Am. Ind. Hyg. J., 48, 158
- Held B. J., 1970, History of Respiratory Protective Devices in the US
- Cohen H. J., 1984, J. Int. Soc. Respir. Prot., 2, 305
- McClave J. T., 2006, Statistics,
Cited by
Wagner, J., Macher, J. M., Chen, W., & Kumagai, K. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315555 · Cited by 14
Metadata
- Authors
- Oestenstad, R. K., & Bartolucci, A. A.
- Affiliations
- University of Alabama at Birmingham (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2010-04-08
- Volume
- 7
- Issue
- 6
- Pages
- 332-341
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2053309387
- Cited by
- 54
- References
- 17
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 8 · 2023: 7 · 2022: 7 · 2021: 11 · 2020: 1 · 2019: 1 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 4
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (1K01OH00085)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- half-mask respirators, facial dimensions, respirator fit testing, fluorescent tracers, gender differences, respirator selection
- MeSH terms
- Adult, Anthropometry, Equipment Design, Face, Female, Humans, Male, Middle Aged, Respiratory Protective Devices, Sex Factors, Equipment Failure Analysis, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators. https://app.cochat.ai/papers/10.1080/15459621003729909
- The paper
- Oestenstad, R. K., & Bartolucci, A. A. (2010). Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459621003729909
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.