Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison Testing
The DOI matches its Crossref record.
Abstract
This article, the second in a series of three, describes the method comparison testing portion of a study conducted to compare the fit factors from six quantitative fit-tests (QNFT) with a measure of a respirator wearer's actual exposure assessed by end-exhaled air analysis for 1,1,2-trichloro-1,2,2-trifluoroethane (Freon-113) under the same conditions. The six QNFT methods were (1) continuous low flow, flush probe; (2) continuous high flow, deep probe (CHD); (3) exhalation valve discharge (EVD); (4) controlled negative pressure; (5) 10-minute Ambient Aerosol 1 (AA1); and (6) 30-minute Ambient Aerosol 2. The first three methods utilized corn oil and a forward light scattering photometer. The last two methods used the TSI Portacount. Respirators used in the study were both disposable and elastomeric organic vapor/high efficiency half-masks. The characterization equations from the preliminary research (described previously) were used to determine the actual exposure to Freon-113 during the method comparison testing. The fit factors resulting from the QNFT methods were then individually correlated with the Freon-113 exposures using the coefficient of determination, R2. The lowest R2 value, 0.20, was found with the EVD method. The highest R2 values, 0.81 and 0.78, were associated, respectively, with the CHD and AA1 methods. This study suggests that some QNFT methods may be used to estimate actual respirator performance under laboratory conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490433799 · Cited by 119
“It has been shown the fit factors provided by the PortaCount Plus may overestimate the exposure of a respirator wearer under actual working conditions.(16) The second limitation was the subject panel.”
MethodSelf-citationThe Effect of Subject Characteristics and Respirator Features on Respirator Fit
Zhuang, Z., Coffey, C. C., & Ann, R. B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500391668 · Cited by 93
“The six-donning, six-exercise SWPF procedure used in this study has been demonstrated, in a simulated healthcare workplace test, to provide fit factors that have a high correlation with a wearer’s actual exposure.(21) Before starting an SWPF test, a subject donned the respirator per the respirator manufacturer’s instr…”
MethodSelf-citationSimulated workplace protection factors for half-facepiece respiratory protective devices
Duling, M. G., Lawrence, R. B., Slaven, J. E., & Coffey, C. C. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701346925 · Cited by 52
Self-citation
Metadata
- Authors
- Coffey, C. C., Campbell, D. L., Myers, W. R., & Zhuang, Z.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1998-12
- Volume
- 59
- Issue
- 12
- Pages
- 862-870
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2004150084
- Cited by
- 40
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison Testing. https://app.cochat.ai/papers/10.1080/15428119891011036
- The paper
- Coffey, C. C., Campbell, D. L., Myers, W. R., & Zhuang, Z. (1998). Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison Testing. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15428119891011036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.