CoChat

Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison Testing

Coffey, Christopher C., Campbell, Donald L., Myers, Warren R., Zhuang, Ziqing · 1998 · American Industrial Hygiene Association Journal
Cited by 40

The DOI matches its Crossref record.

Abstract

This article, the second in a series of three, describes the method comparison testing portion of a study conducted to compare the fit factors from six quantitative fit-tests (QNFT) with a measure of a respirator wearer's actual exposure assessed by end-exhaled air analysis for 1,1,2-trichloro-1,2,2-trifluoroethane (Freon-113) under the same conditions. The six QNFT methods were (1) continuous low flow, flush probe; (2) continuous high flow, deep probe (CHD); (3) exhalation valve discharge (EVD); (4) controlled negative pressure; (5) 10-minute Ambient Aerosol 1 (AA1); and (6) 30-minute Ambient Aerosol 2. The first three methods utilized corn oil and a forward light scattering photometer. The last two methods used the TSI Portacount. Respirators used in the study were both disposable and elastomeric organic vapor/high efficiency half-masks. The characterization equations from the preliminary research (described previously) were used to determine the actual exposure to Freon-113 during the method comparison testing. The fit factors resulting from the QNFT methods were then individually correlated with the Freon-113 exposures using the coefficient of determination, R2. The lowest R2 value, 0.20, was found with the EVD method. The highest R2 values, 0.81 and 0.78, were associated, respectively, with the CHD and AA1 methods. This study suggests that some QNFT methods may be used to estimate actual respirator performance under laboratory conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/15428119891011036

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 40

Metadata

Authors
Coffey, C. C., Campbell, D. L., Myers, W. R., & Zhuang, Z.
Venue
American Industrial Hygiene Association Journal
Published
1998-12
Volume
59
Issue
12
Pages
862-870
ISSN
0002-8894 (ISSN-L)
OpenAlex
W2004150084
Cited by
40
References
0
FWCI
2.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison Testing. https://app.cochat.ai/papers/10.1080/15428119891011036
The paper
Coffey, C. C., Campbell, D. L., Myers, W. R., & Zhuang, Z. (1998). Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison Testing. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15428119891011036

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.