Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Certain respiratory tract infections are transmitted through air. Coughing and sneezing by an infected person can emit pathogen-containing particles with diameters less than 10 microm that can reach the alveolar region. Based on our analysis of the sparse literature on respiratory aerosols, we estimated that emitted particles quickly decrease in diameter due to water loss to one-half the initial values, and that in one cough the volume in particles with initial diameters less than 20 microm is 60 x 10(-8) mL. The pathogen emission rate from a source case depends on the frequency of expiratory events, the respirable particle volume, and the pathogen concentration in respiratory fluid. Viable airborne pathogens are removed by exhaust ventilation, particle settling, die-off, and air disinfection methods; each removal mechanism can be assigned a first-order rate constant. The pathogen concentration in well-mixed room air depends on the emission rate, the size distribution of respirable particles carrying pathogens, and the removal rate constants. The particle settling rate and the alveolar deposition fraction depend on particle size. Given these inputs plus a susceptible person's breathing rate and exposure duration to room air, an expected alveolar dosemicrois estimated. If the infectious dose is one organism, as appears to be true for tuberculosis, infection risk is estimated by the expression: R = 1-exp(-micro). Using published tuberculosis data concerning cough frequency, bacilli concentration in respiratory fluid, and die-off rate, we illustrate the model via a plausible scenario for a person visiting the room of a pulmonary tuberculosis case. We suggest that patients termed "superspreaders" or "dangerous disseminators" are those infrequently encountered persons with high values of cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous authors have noted that the viral load of human-emitted infectious aerosols may depend on sputum volume [31,42].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731 · cited 3×
“However, if the infec-tious dose is 10 organisms, infection risk is only 1.1 × 10 −7 according to the above expression based on Equation 14 .”
BackgroundInfluentialGuideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850 · cited 1×
“These studies were published by Duguid (15) in 1946, Louden and Roberts ( eq 4) in 1967, and Papineni and Rosenthal (16) in 1997.”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 10×
“The Papineni and Rosenthal findings substantially differ from the data reported by Duguid and by Louden and Roberts (hereafter denoted L&R).”
BackgroundInfluential(2001) · Cited by 666
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602 · cited 1×
“W.F. Wells (4) argued that droplets derived from respiratory fluid with d a < 100 µm rapidly evaporate to become droplet nuclei before they can be removed from air by gravitational settling.”
BackgroundDilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386 · cited 2×
“The regression equation did not account for water loss from the larger particles prior to deposition onto bond paper,(13) and there was no adjustment for evaporative water loss from the smaller particles collected on the Millipore filter.”
BackgroundRiley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
Airborne Contagion and Air Hygiene
Phair, J. J. (1955) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.45.11.1495-c · Cited by 257
Murray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 1×
“5 ach is a typical residential air exchange rate.(31) Airborne M.”
BackgroundDroplet expulsion from the respiratory tract.
(1967) · PubMed · doi:10.1164/arrd.1967.95.3.435 · Cited by 240 · cited 1×
“It has been suggested that respiratory particle diameters are approximately lognormally distributed.(6,12) It would be convenient if the lognormal model were a good descriptor, because V20 could be estimated using the geometric mean (GM) and geometric standard deviation (GSD) of the particle count distribution by diam…”
MethodQuantitative studies of mycobacterial populations in sputum and saliva.
Yeager, H., Lacy, J., Smith, L. R., & LeMaistre, C. A. (1967) · PubMed · doi:10.1164/arrd.1967.95.6.998 · Cited by 227 · cited 1×
“4×107 mL−1).(30) Assume that cough particles adhere to the adjusted L&R distribution shown in Table V for particles with deq ≤ 10 μm.”
BackgroundClearing the Air: The Theory and Application of Ultraviolet Air Disinfection
Riley, R. L., & Nardell, E. A. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.5.1286 · Cited by 204
Quantitative Studies of Mycobacterial Populations in Sputum and Saliva1, 2
Yeager, H., Lacy, J., Smith, L. R., et al. (2015) · American Review of Respiratory Disease · Cited by 149
Effectiveness of In-Room Air Filtration and Dilution Ventilation for Tuberculosis Infection Control
Miller, S. L., Lohascio, C., Nazaroff, W. W., & Macher, J. M. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467523 · Cited by 145
Self-citationCough frequency in patients with respiratory disease.
Loudon, R. G., & Brown, L. C. (1967) · PubMed · doi:10.1164/arrd.1967.96.6.1137 · Cited by 103 · cited 2×
“(29) In the previous scenario, a five-fold increase in C F to 2.5 × 10 7 mL −1 , a five-fold increase in cough frequency E to 50 h −1 , and a five-fold increase in V 20 to 3 × 10 −7 mL, would yield G = 370 h −1 , C AV = 5 m −3 , and µ = 1. Infection risk via airborne transmission would then increase to 63% with just 1…”
BackgroundInfluentialLoudon, R. G., & ROBERTS, R. M. (1967) · Nature · doi:10.1038/213095a0 · Cited by 71 · cited 1×
“The equation was derived from the results of a separate study that evaluated the stain diameters of liquid particles with initial diameters in the 35 to 280 μm range after impaction onto bond paper.(17) Because the regression equation did not apply to smaller particles, it was assumed that a particle with a stain diam…”
MethodWestwood, J. C. N., Boulter, E. A., Bowen, E. T. W., & Maber, H. B. (1966) · PubMed · Cited by 68
Hamburger, M., & ROBERTSON, O. H. (1948) · The American Journal of Medicine · doi:10.1016/s0002-9343(48)90392-1 · Cited by 65 · cited 2×
“A study by Hamburger and Robertson(20) used subjects who were nose and throat culture positive for group A hemolytic streptococci.”
Markov Modeling of Contaminant Concentrations in Indoor Air
Nicas, M. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984559 · Cited by 56 · cited 1×
“In addition, the WMR construct ignores the higher exposure intensity (and higher infection risk) that would pertain close to the emission source.(34,35) We also note that our hypothetical G = 3 h−1”
BackgroundSelf-citationAerial transmission of mycobacteria.
Loudon, R. G., Bumgarner, L. R., Lacy, J., & Coffman, G. K. (1969) · PubMed · doi:10.1164/arrd.1969.100.2.165 · Cited by 56 · cited 1×
“tuberculosis bacilli are reported to lose viability with a half-time of 6 h,(32) which corresponds to α3 = ln(2)/(6 h) = 0.”
BackgroundPrevention, C. F. D. C. A., & Serivce, P. H. (1996) · American Journal of Infection Control · doi:10.1016/s0196-6553(96)90051-6 · Cited by 56
Druett, H. A., Robinson, J. M., Henderson, D. W., PACKMAN, L. P., & Peacock, S. (1956) · Journal of Hygiene · doi:10.1017/s0022172400044284 · Cited by 55 · cited 3×
“These studies were published by Duguid (15) in 1946, Louden and Roberts (10) in 1967, and Papineni and Rosenthal (16) in 1997.”
BackgroundInfluentialRabbit pox: An experimental study of the pathways of infection in rabbits
Bedson, H. S., & Duckworth, M. (1963) · The Journal of Pathology and Bacteriology · doi:10.1002/path.1700850102 · Cited by 54
Speck, R. S., & Wolochow, H. (1957) · The Journal of Infectious Diseases · doi:10.1093/infdis/100.1.58 · Cited by 51 · cited 1×
“We note that if the infectious dose is more than one organism, as appears to be the case for the pneumonic plague agent Yersinia pestis, (28) Equation 11 is not valid.”
BackgroundTransmission and Deposition Behavior of Aerosols in Sampling Inlets
Okazaki, K., & Willeke, K. (1987) · Aerosol Science and Technology · doi:10.1080/02786828708959164 · Cited by 51 · cited 1×
“(18, 19) Moreover, we judge the results of a bioaerosol study described below to be inconsistent with the particle size data offered by Papineni and Rosenthal, but consistent with the Duguid and L&R data.”
ResultMeyer, K. F. (1961) · Bacteriological Reviews · doi:10.1128/br.25.3.249-261.1961 · Cited by 51
TUBERCULOSIS INDUCED BY DROPLET NUCLEI INFECTION1
Ratcliffe, H. L. (1952) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a119504 · Cited by 50
PATHOGENESIS OF VARIOLA IN MACACA IRUS MONKEYS1
Hahon, N., & Wilson, B. (1960) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a120091 · Cited by 41
THE ROLE OF PARTICLE SIZE IN EXPERIMENTAL AIR-BORNE INFECTION1
Sonkin, L. S. (1951) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a119459 · Cited by 38
Nicas, M., & Hubbard, A. (2002) · Risk Analysis · doi:10.1111/1539-6924.00279 · Cited by 33 · cited 1×
“Although Wells and Riley inappropriately generalized the equation to the circumstance in which the infectious dose is greater than one,(23) Equation 11 is expected to apply to M.”
BackgroundSelf-citationImmunological Abnormalities in Juvenile Myelomonocytic Leukaemia
Cannat, A., & Seligmann, M. (1973) · BMJ · doi:10.1136/bmj.1.5845.71 · Cited by 31
The Infectious Dose of Variola (Smallpox) Virus
Nicas, M., Hubbard, A., Jones, R. M., & Reingold, A. L. (2004) · Applied Biosafety · doi:10.1177/153567600400900302 · Cited by 30
Self-citationMitman, M. (1945) · BMJ · doi:10.1136/bmj.1.4385.71 · Cited by 17 · cited 3×
“tuberculosis bacilli are reported to lose viability with a half-time of 6 h,(32) which corresponds to α3 = ln(2)/(6 h) = 0.”
BackgroundNYKA, W. (1962) · PubMed · doi:10.1164/arrd.1962.85.1.33 · Cited by 15
Research works printed but not linked: 6
- 4. Wells, W.F.: Onair-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20 :611-618 (1934).
- 5. Hinds, W.C.: Aerosol Technology . New York: John Wiley & Sons, Inc., 57-58:211-221 (1982).
- 7. Sonkin, L.S.: The role of particle size in experimental airborne infection. Am. J. Hyg. 53 :337-354 (1951).
- 21. Jennison, M.W.: Atomizing of mouth and nose secretions into the air as revealed by high-speed photography. In Aerobiology (Pub. No. 17). Washington, D.C.: American Association for the Advancement of Science, 1942. pp. 106-128.
- 33. Office of Research and Development: Exposure Factors Handbook (Draft). Washington, D.C.: U.S. Environmental Protection Agency, 1996. pp. 5-22.
- 36. Riley, R.L., C.C. Mills, F. O'Grady, L.U. Sultan, F. Wittstadt, and D.N. Shivpuri: Infectiousness of air from a tuberculosis ward. Am. Rev. Resp. Dis. 85 :511-525 (1962).
Cited by
Jayaweera, M., Perera, H., Gunawardana, B., & Manatunge, J. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109819 · Cited by 1,238
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
“Smaller pathogen-laden droplets have higher infectivity (Nicas, Nazaroff, & Hubbard, 2005) compared to the larger ones for diseases that have the lower respiratory tract as the target infection site (e.g., tuberculosis).”
BackgroundMethodInfluentialAbsolute humidity modulates influenza survival, transmission, and seasonality
Shaman, J., & Kohn, M. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806852106 · Cited by 1,045
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
“, 2004; Hamburger and Roberston, 1946; Jennison, 1942; Loudon and Roberts, 1967; Papineni and Rosenthal, 1997) and excellent reviews exist (Morawska, 2005; Nicas et al., 2005).”
Background
Metadata
- Authors
- Nicas, M., Nazaroff, W. W., & Hubbard, A.
- Affiliations
- University of California, Berkeley (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-03
- Volume
- 2
- Issue
- 3
- Pages
- 143-154
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- PMC
- PMC7196697
- OpenAlex
- W2160555964
- Cited by
- 867
- References
- 36
- Citations by year
- 2026: 23 · 2025: 55 · 2024: 56 · 2023: 75 · 2022: 100 · 2021: 149 · 2020: 93 · 2019: 12 · 2018: 22 · 2017: 17 · 2016: 20 · 2015: 25 · 2014: 21 · 2013: 34 · 2012: 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centers for Disease Control and Prevention
- National Institute for Occupational Safety and Health
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Keywords
- airborne transmission, respiratory aerosols, respiratory pathogens, tuberculosis, cough, sneezing, particle size distribution, alveolar deposition, air disinfection, ventilation, superspreaders, infection risk, infectious dose, indoor air exposure
- MeSH terms
- Aerosols, Cough, Humans, Models, Theoretical, Particle Size, Pulmonary Alveoli, Risk Factors, Tuberculosis, Pulmonary, Risk Assessment, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.