Filtration Performance of NIOSH-Approved N95 and P100 Filtering Facepiece Respirators Against 4 to 30 Nanometer-Size Nanoparticles
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This study investigated the filtration performance of NIOSH-approved N95 and P100 filtering facepiece respirators (FFR) against six different monodisperse silver aerosol particles in the range of 4-30 nm diameter. A particle test system was developed and standardized for measuring the penetration of monodisperse silver particles. For respirator testing, five models of N95 and two models of P100 filtering facepiece respirators were challenged with monodisperse silver aerosol particles of 4, 8, 12, 16, 20, and 30 nm at 85 L/min flow rate and percentage penetrations were measured. Consistent with single-fiber filtration theory, N95 and P100 respirators challenged with silver monodisperse particles showed a decrease in percentage penetration with a decrease in particle diameter down to 4 nm. Penetrations less than 1 particle/30 min for 4-8 nm particles for one P100 respirator model, and 4-12 nm particles for the other P100 model, were observed. Experiments were also carried out with larger than 20 nm monodisperse NaCl particles using a TSI 3160 Fractional Efficiency Tester. NaCl aerosol penetration levels of 20 nm and 30 nm (overlapping sizes) particles were compared with silver aerosols of the same sizes by a three-way ANOVA analysis. A significant (p < 0.001) difference between NaCl and silver aerosol penetration levels was obtained after adjusting for particle sizes and manufacturers. A significant (p = 0.001) interaction with manufacturers indicated the difference in NaCl, and silver aerosol penetrations were not the same across manufacturers. The two aerosols had the same effect across 20 nm and 30 nm sizes as shown by the absence of any significant (p = 0.163) interaction with particle sizes. In the case of P100 FFRs, a significant (p < 0.001) difference between NaCl and silver aerosol (20 nm and 30 nm) penetrations was observed for both respirator models tested. The filtration data for 4-30 nm monodisperse particles supports previous studies that indicate NIOSH-approved air-purifying respirators provide expected levels of filtration protection against nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
Electrostatic Respirator Filter Media: Filter Efficiency and Most Penetrating Particle Size Effects
Martin, S. B., & Moyer, E. S. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050075617 · Cited by 156
Filtration efficiency of a fibrous filter for nanoparticles
Kim, C. S., Bao, L., Okuyama, K., Shimada, M., & Niinuma, H. (2006) · Journal of Nanoparticle Research · doi:10.1007/s11051-005-9017-x · Cited by 111 · cited 3×
“(24) One study observed thermal rebound effects for particles below 2 nm size.(26) However, the likelihood of monodisperse nanoparticles in that size range (<2 nm) appearing in workplaces is negligible because they would agglomerate quickly.”
BackgroundResultPenetration of 4.5nm to aerosol particles through fibrous filters
Huang, S.-H., Chen, C.-W., Chang, C.-P., Lai, C.-Y., & Chen, C.-C. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.007 · Cited by 108 · cited 1×
“( 21 ) Their results showed that almost all particles below 10 nm were collected by the FFRs.”
BackgroundLee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., Zeigler, H. L., & Reponen, T. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500330583 · Cited by 73
Cited by
Nanoparticles, human health hazard and regulation
Seaton, A., Tran, L., Aitken, R., & Donaldson, K. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0252.focus · Cited by 350
Facemasks for the prevention of infection in healthcare and community settings
MacIntyre, C. R., & Chughtai, A. A. (2015) · BMJ · doi:10.1136/bmj.h694 · Cited by 328
(2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mer122 · Cited by 75
Self-citationHe, X., Reponen, T., McKay, R. T., & Grinshpun, S. A. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2013.829209 · Cited by 64
MOSTOFI, R., WANG, B., HAGHIGHAT, F., BAHLOUL, A., & JAIME, L. (2010) · Industrial Health · doi:10.2486/indhealth.48.296 · Cited by 58
Metadata
- Authors
- Rengasamy, S., King, W. P., Eimer, B. C., & Shaffer, R. E.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2008-07-23
- Volume
- 5
- Issue
- 9
- Pages
- 556-564
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W1984518103
- Cited by
- 124
- References
- 6
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Filtration Performance of NIOSH-Approved N95 and P100 Filtering Facepiece Respirators Against 4 to 30 Nanometer-Size Nanoparticles. https://app.cochat.ai/papers/10.1080/15459620802275387
- The paper
- Rengasamy, S., King, W. P., Eimer, B. C., & Shaffer, R. E. (2008). Filtration Performance of NIOSH-Approved N95 and P100 Filtering Facepiece Respirators Against 4 to 30 Nanometer-Size Nanoparticles. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459620802275387
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.