CoChat

Validity and Reliability of Multiparameter Physiological Measurements Recorded by the Equivital Lifemonitor During Activities of Various Intensities

Liu, Yan, Zhu, Shai H., Wang, Guo H., Ye, Fei, Li, Peng Z. · 2013 · Journal of Occupational and Environmental Hygiene
Cited by 127

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The Equivital LifeMonitor EQ02 is a multiparameter body-worn system capable of logging and transmitting physiological data describing a wearer's cardiorespiratory and thermal status. A number of vital signs can be acquired by the system, including electrocardiography, respiratory inductance plethysmography, posture/activity, multipoint skin temperature, and core temperature. The validity and reliability of the multiparameter physiological data recorded by the EQ02 were assessed. Participants performed resting, low-, and moderate intensity activities and wore the EQ02 and other calibrated laboratory physiological monitoring devices simultaneously. Heart rate, respiratory rate, multipoint skin temperature, and core temperature recorded by the EQ02 were compared with measurements recorded by standard devices. Results show that the validity error scores for HR and RR for all three activities were not significantly different from zero, and the CV, 95% LOA, and r were all clinically accepted. The validity error score for MT(SK) (0.59°C) falls outside the limits of 0.5°C, but the differences were parallel, r remained high (0.96), and 95% LOA remained narrow (±0.88°C). The validity error score for T(C) (-0.1°C) was similar in direction and magnitude to other studies, and r (0.98) and 95% LOA (±0.22°C) showed acceptable agreement between devices. The reliability error scores for HR, RR, MT(SK), and T(C) between trials were significantly different from zero. The 95% LOA, CV, and ICC for the EQ02 were similar to standard devices and were all clinically accepted. These findings demonstrate the validity and reliability of the EQ02 for ambulatory monitoring of multiple physiological parameters and suggest that the system could be used to provide a complete human physiological monitoring platform for the study of occupational health, environmental hygiene, and other application fields requiring ambulatory monitoring of multiparameter physiological status.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/15459624.2012.747404

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 127

Metadata

Authors
Liu, Y., Zhu, S. H., Wang, G. H., Ye, F., & Li, P. Z.
Venue
Journal of Occupational and Environmental Hygiene
Published
2012-12-21
Volume
10
Issue
2
Pages
78-85
ISSN
  • 1545-9624 (ISSN-L)
  • 1545-9632
OpenAlex
W2129163354
Cited by
127
References
3
FWCI
1.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity and Reliability of Multiparameter Physiological Measurements Recorded by the Equivital Lifemonitor During Activities of Various Intensities. https://app.cochat.ai/papers/10.1080/15459624.2012.747404
The paper
Liu, Y., Zhu, S. H., Wang, G. H., Ye, F., & Li, P. Z. (2013). Validity and Reliability of Multiparameter Physiological Measurements Recorded by the Equivital Lifemonitor During Activities of Various Intensities. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459624.2012.747404

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.