Validity and Reliability of Multiparameter Physiological Measurements Recorded by the Equivital Lifemonitor During Activities of Various Intensities
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The Equivital LifeMonitor EQ02 is a multiparameter body-worn system capable of logging and transmitting physiological data describing a wearer's cardiorespiratory and thermal status. A number of vital signs can be acquired by the system, including electrocardiography, respiratory inductance plethysmography, posture/activity, multipoint skin temperature, and core temperature. The validity and reliability of the multiparameter physiological data recorded by the EQ02 were assessed. Participants performed resting, low-, and moderate intensity activities and wore the EQ02 and other calibrated laboratory physiological monitoring devices simultaneously. Heart rate, respiratory rate, multipoint skin temperature, and core temperature recorded by the EQ02 were compared with measurements recorded by standard devices. Results show that the validity error scores for HR and RR for all three activities were not significantly different from zero, and the CV, 95% LOA, and r were all clinically accepted. The validity error score for MT(SK) (0.59°C) falls outside the limits of 0.5°C, but the differences were parallel, r remained high (0.96), and 95% LOA remained narrow (±0.88°C). The validity error score for T(C) (-0.1°C) was similar in direction and magnitude to other studies, and r (0.98) and 95% LOA (±0.22°C) showed acceptable agreement between devices. The reliability error scores for HR, RR, MT(SK), and T(C) between trials were significantly different from zero. The 95% LOA, CV, and ICC for the EQ02 were similar to standard devices and were all clinically accepted. These findings demonstrate the validity and reliability of the EQ02 for ambulatory monitoring of multiple physiological parameters and suggest that the system could be used to provide a complete human physiological monitoring platform for the study of occupational health, environmental hygiene, and other application fields requiring ambulatory monitoring of multiparameter physiological status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“The validity of the HR measurements was similar to the results of other studies that also found lower validity coefficients at higher speeds.(15,17) According to the Bland-Altman method, devices with a narrower 95% LOA around zero are more likely to be valid and reliable.”
ResultMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Cited by
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Redwine, L. S., Henry, B. L., Pung, M. A., Wilson, K., Chinh, K., Knight, B., Jain, S., Rutledge, T., Greenberg, B., Maisel, A., et al. (2016) · Psychosomatic Medicine · doi:10.1097/psy.0000000000000316 · Cited by 108
Metadata
- Authors
- Liu, Y., Zhu, S. H., Wang, G. H., Ye, F., & Li, P. Z.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2012-12-21
- Volume
- 10
- Issue
- 2
- Pages
- 78-85
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2129163354
- Cited by
- 127
- References
- 3
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity and Reliability of Multiparameter Physiological Measurements Recorded by the Equivital Lifemonitor During Activities of Various Intensities. https://app.cochat.ai/papers/10.1080/15459624.2012.747404
- The paper
- Liu, Y., Zhu, S. H., Wang, G. H., Ye, F., & Li, P. Z. (2013). Validity and Reliability of Multiparameter Physiological Measurements Recorded by the Equivital Lifemonitor During Activities of Various Intensities. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459624.2012.747404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.