Tender or not tender: test-retest repeatability of pressure pain thresholds in the trapezius and deltoid muscles of healthy women
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To examine the test-retest repeatability of pressure pain thresholds in the shoulder muscles of healthy women. DESIGN: Four experimental sessions (days 1, 3, 28, 30), each including 4 consecutive pressure pain threshold measurements at 10-minute intervals. SUBJECTS: Twenty-four healthy female volunteers, mean age 42 years. METHODS: Two examiners measured pressure pain thresholds bilaterally over the trapezius and deltoid muscles with an electronic algometer. Student's paired t-test, intraclass correlation coefficient, ANOVA repeated measures, 95% confidence interval and mean maximal absolute measurement error, were used for statistics. RESULTS: Reliability for each point in all sessions was high; ICC range 0.70-0.94, mean maximal differences; 53-102 kPa (all 4 muscles), and between points in each muscle: ICC right trapezius 0.59-0.77, left 0.67-0.84, right deltoid 0.66-0.83, left 0.70-0.90. Mean maximal differences were 69-101 kPa and 65-111 kPa for the trapezius and deltoid muscles, respectively. The inter-individual variation was 5-fold (trapezius 88-574 kPa; deltoid 91-529 kPa). At the group level, the variation was limited when the first measurement was excluded. Inter-rater and intra-rater repeatability was high without significant differences. Only small side-to-side differences were seen. CONCLUSION: Repeated measurements show stable intra-individual values. The method can be recommended when used by trained and experienced examiners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Myofascial pain and dysfunction : the trigger point manual
Travell, J. G., & Simons, D. G. (1982) · Medical Entomology and Zoology · Cited by 2,735
Advances in Pain Research and Therapy
Wang, J. K. (1980) · Anesthesia & Analgesia · doi:10.1213/00000539-198002000-00022 · Cited by 2,255
Fischer, A. A. (1987) · Pain · doi:10.1016/0304-3959(87)90089-3 · Cited by 958 · cited 6×
“collar workers with good communication skills, and were clearly instructed about the threshold criterion when the pressure gave rise to “pain or discomfort” which is similar to the criterion defined and employed by Fischer (5).”
BackgroundMethodInfluentialRankin, G., & Stokes, M. (1998) · Clinical Rehabilitation · doi:10.1191/026921598672178340 · Cited by 856 · cited 1×
“ICC 2,1 uses a two-way ANOVA model where we consider the raters to be randomly selected from a population of raters, i.e. a random factor ( 34 ).”
MethodInterrater reliability in myofascial trigger point examination
Gerwin, R. D., Shannon, S., Hong, C.-Z., Hubbard, D., & Gevirtz, R. (1997) · Pain · doi:10.1016/s0304-3959(96)03248-4 · Cited by 691 · cited 2×
“Some researchers have studied PPTs (4, 24) and examination (25, 26) of trigger points, and found varying inter-rater reliability.”
BackgroundEliasziw, M., Young, S. L., Woodbury, M. G., & Fryday-Field, K. (1994) · Physical Therapy · doi:10.1093/ptj/74.8.777 · Cited by 635 · cited 1×
“(27), about using statistical methods based on repeated-measures design, when both inter-rater and intra-rater reliability are being assessed.”
MethodPressure-pain threshold in human temporal region. Evaluation of a new pressure algometer
Jensen, K., Andersen, H. Ø., Olesen, J., & Lindblom, U. (1986) · Pain · doi:10.1016/0304-3959(86)90235-6 · Cited by 425 · cited 7×
“able to show that consecutive measurements of PPTs over the same point reveal little variation and that no measurement effects of repeated pressure application to the same point can be seen (9, 12, 35).”
BackgroundMethodResultInfluentialReliability of Clinical Pressure-Pain Algometric Measurements Obtained on Consecutive Days
Nussbaum, E. L., & Downes, L. (1998) · Physical Therapy · doi:10.1093/ptj/78.2.160 · Cited by 416 · cited 4×
“The reliability of measuring PPTs using an electronic algometer supplemented with a push button, has been studied in the whole body (18, 19), or in a specific region (9, 12, 20, 21).”
BackgroundMethodInfluentialReliability of the pressure algometer as a measure of myofascial trigger point sensitivity
Reeves, J. L., Jaeger, B., & Graff-Radford, S. B. (1986) · Pain · doi:10.1016/0304-3959(86)90117-x · Cited by 389
Cited by
Chesterton, L. S., Sim, J., Wright, C. C., & Foster, N. E. (2007) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e318154b6ae · Cited by 691
Walton, D., MacDermid, J., Nielson, W., Teasell, R., Chiasson, M., & Brown, L. (2011) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2011.3666 · Cited by 510
Fundamentals of muscle pain, referred pain, and deep tissue hyperalgesia
Graven‐Nielsen, T. (2006) · Scandinavian Journal of Rheumatology · doi:10.1080/03009740600865980 · Cited by 227
Wylde, V., Palmer, S., Learmonth, I. D., & Dieppe, P. (2011) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2011.02.009 · Cited by 169
Rakel, B. A., Zimmerman, B. M., Geasland, K., Embree, J., Clark, C. R., Noiseux, N. O., Callaghan, J. J., Herr, K., Walsh, D., & Sluka, K. A. (2014) · Pain · doi:10.1016/j.pain.2014.09.025 · Cited by 115
“94) [15,27,53,55,74].”
Reliability of pain threshold measurement in young adults
Cathcart, S., & Pritchard, D. (2006) · The Journal of Headache and Pain · doi:10.1007/s10194-006-0265-7 · Cited by 110
“More recently, some studies of PPT reliability have used ICC to confirm reliability assessed by analogue algometers [15], electronic algometers [7, 16], dolorimeters [17] and novel computer-controlled devices [18].”
Jakobsen, M. D., Sundstrup, E., Brandt, M., & Andersen, L. L. (2018) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2018.01.006 · Cited by 47
Metadata
- Authors
- Persson, A., Brogårdh, C., & Sjölund, B.
- Venue
- Journal of Rehabilitation Medicine
- Publisher
- Medical Journals Sweden AB
- Published
- 2004-01-01
- Volume
- 36
- Issue
- 1
- Pages
- 17-27
- ISSN
- 1650-1977 (ISSN-L)
- OpenAlex
- W2149218269
- Cited by
- 173
- References
- 32
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.