Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise
The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.
Abstract
Introduction: The Moxy is a novel, cutaneously placed muscle oxygen monitor which claims to measure local oxygen saturation (SmO 2 ) and total haemoglobin (THb) using near‐infrared spectroscopy. If shown to be reliable, its data storage and telemetric capability will be useful for assessing localised O 2 usage during field‐based exercise. This study investigated the reliability of the Moxy during cycling and assessed the correlations between its measurements, whole‐body O 2 consumption (VO 2 ) and heart rate (HR). Methods: Ten highly trained cyclists performed an incremental, step‐wise cycling protocol on two occasions while wearing the Moxy. SmO 2 , THb, VO 2 and HR were recorded in the final minute of each five‐minute stage. Data were analysed using Spearman's Order‐Rank Coefficient (SROC), Intraclass Correlation (ICC), and Coefficient of Variance (COV). Significance was set at p ≤ .05. Results: SmO 2 showed a ‘strong’ or ‘very large’ correlation between trials (SROC: r = 0.842–0.993, ICC: r = 0.773–0.992, p ≤ .01) and was moderately correlated with VO 2 and HR ( r = −0.71–0.73, p ≤ .01). SmO 2 showed a moderate to high reliability at low intensities, but this decreased as relative exercise intensity increased. THb showed poor correlations between tests and with the other measured variables, but was highly reliable at all power outputs. Conclusions: The Moxy is a reliable device to measure SmO 2 at low to moderate intensities, but at higher intensities, greater variation in measurements occurs, likely due to tissue ischaemia or increased movement artefacts due to more frequent muscular contractions. THb has low variation during exercise, and does not appear to be a valid indicator of muscle oxygenation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“at higher intensity there is a greater standard deviation of SmO2”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Crum et al., 2017
In the citing paper
“However, there is some discrepancy since it does state that it is actually valid in an incremental cycle machine test (Crum et al., 2017), and in another incremental race test it is mentioned that it depends on the subject (Austin et al., 2005).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Crum et al., 2017
In the citing paper
“The Moxy Monitor has been compared with alternate NIRS device and evaluated for reliability and validity in previously published papers.7,34”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [34]
In the citing paper
“Wearable near-infrared spectroscopy (NIRS) measurements of muscle oxygen saturation (SmO2) demonstrated good test–retest reliability at rest.”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [5]
In the citing paper
“Our ICC scores across workloads were comparable to those by Crum et al., who also looked at the reliability of wearable NIRS during an incremental exercise test (IET) (5).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [5]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899 · cited 1×
“The process is based on the differential proportion of wavelengths which are absorbed by oxygenated and deoxygenated Hb (De Blasi, Cope, Elwell, Safoue, & Ferrari, 1993; Jobsis, 1977).”
BackgroundLimiting factors for maximum oxygen uptake and determinants of endurance performance
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200001000-00012 · Cited by 2,410 · cited 1×
“In addition, the greater rate of mechanical work requiring the greater VO2 results in an increased concentration of intramuscular adenine diphosphate, which signals a need for more oxidative ATP production and further promotes O2 movement into the muscle (Bassett & Howley, 2000).”
BackgroundValidation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 2×
“…the NIRS method has been demonstrated through its highly significant correlations with venous O2 saturation at rest and during exercise (r= 0.92) (Mancini et al., 1994), and from the reproducibility of its measurements during repeated incremental running (r = 0.87–0.88) and cycling (r =…”
BackgroundMethodInfluentialMuscle coordination of maximum-speed pedaling
Raasch, C. C., Zajac, F. E., Ma, B., & Levine, W. S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00188-1 · Cited by 362
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
Davis, S. L., Fadel, P. J., Cui, J., Thomas, G. D., & Crandall, C. G. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2005 · Cited by 179
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149 · cited 4×
“Minute ventilation (VE) and concentrations of O2 and CO2 values were used to calculate the volume of inspired air (VI) using the Haldane transformation, where VE was corrected for barometric pressure, ambient temperature and atmospheric water saturation.”
BackgroundInfluentialO2 transport and its interaction with metabolism; a systems view of aerobic capacity
HONIG, C. R., CONNETT, R. J., & GAYESKI, T. E. J. (1992) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199201000-00009 · Cited by 91
Tew, G. A., Klonizakis, M., Moss, J., Ruddock, A. D., Saxton, J., & Hodges, G. J. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.12.001 · Cited by 74 · cited 1×
“In accordance with Tew et al. (2011), COVs of ≤10%, 10–25% and >25% were considered good, moderate and poor.”
Background
Research works printed but not linked: 2
- Cornachione K., 2014, Science and Skiing VI, 369
- McCully K. K., 2000, Near‐infrared spectroscopy: What can it tell us about oxygen saturation in skeletal muscle, Exercise and Sport Sciences Reviews, 28, 123
Cited by
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
“The Moxy Monitor has been compared with alternate NIRS device and evaluated for reliability and validity in previously published papers.(7,34)”
MethodCan Wearable Sweat Lactate Sensors Contribute to Sports Physiology?
Hoovels, K. V., Xuan, X., Cuartero, M., Gijssel, M., Swarén, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01403 · Cited by 143
Seshadri, D. R., Thom, M. L., Harlow, E. R., Gabbett, T. J., Geletka, B. J., Hsu, J. J., Drummond, C. K., Phelan, D. M. J., & Voos, J. E. (2021) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.630576 · Cited by 147
Muscle Oximetry in Sports Science: An Updated Systematic Review
Perrey, S., Quaresima, V., & Ferrari, M. (2024) · Sports Medicine · doi:10.1007/s40279-023-01987-x · Cited by 100
“Currently, wearable NIRS measurements using either PortaMon or Moxy, demonstrated moderate-to-excellent relative reliability scores, and CV as low as 10% for SmO 2 [217, 218].”
Method
Metadata
- Authors
- Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R.
- Affiliations
- Massey University (NZ)
- The Hague University of Applied Sciences (NL)
- Corresponding author
- Crum, E. M.
- Venue
- European Journal of Sport Science
- Publisher
- Wiley
- Published
- 2017-05-30
- Volume
- 17
- Issue
- 8
- Pages
- 1037-1043
- ISSN
- 1536-7290 (ISSN-L)
- 1746-1391
- OpenAlex
- W2618079828
- Cited by
- 206
- References
- 17
- Citations by year
- 2026: 30 · 2025: 25 · 2024: 32 · 2023: 31 · 2022: 27 · 2021: 19 · 2020: 14 · 2019: 20 · 2018: 3 · 2017: 5
- FWCI
- 17.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Journal of Sport Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Massey University
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- muscle oxygen saturation, total hemoglobin, near-infrared spectroscopy, incremental cycling exercise, measurement reliability, whole-body oxygen consumption, heart rate, exercise intensity, muscle oxygenation
- MeSH terms
- Adolescent, Adult, Bicycling, Exercise Test, Female, Heart Rate, Hemoglobins, Humans, Male, Oximetry, Oxygen Consumption, Reproducibility of Results, Muscle, Skeletal, Spectroscopy, Near-Infrared, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.