CoChat

Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise

Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., Stannard, S. R. · 2017 · European Journal of Sport Science

The DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.

Abstract

Introduction: The Moxy is a novel, cutaneously placed muscle oxygen monitor which claims to measure local oxygen saturation (SmO 2 ) and total haemoglobin (THb) using near‐infrared spectroscopy. If shown to be reliable, its data storage and telemetric capability will be useful for assessing localised O 2 usage during field‐based exercise. This study investigated the reliability of the Moxy during cycling and assessed the correlations between its measurements, whole‐body O 2 consumption (VO 2 ) and heart rate (HR). Methods: Ten highly trained cyclists performed an incremental, step‐wise cycling protocol on two occasions while wearing the Moxy. SmO 2 , THb, VO 2 and HR were recorded in the final minute of each five‐minute stage. Data were analysed using Spearman's Order‐Rank Coefficient (SROC), Intraclass Correlation (ICC), and Coefficient of Variance (COV). Significance was set at p ≤ .05. Results: SmO 2 showed a ‘strong’ or ‘very large’ correlation between trials (SROC: r = 0.842–0.993, ICC: r = 0.773–0.992, p ≤ .01) and was moderately correlated with VO 2 and HR ( r = −0.71–0.73, p ≤ .01). SmO 2 showed a moderate to high reliability at low intensities, but this decreased as relative exercise intensity increased. THb showed poor correlations between tests and with the other measured variables, but was highly reliable at all power outputs. Conclusions: The Moxy is a reliable device to measure SmO 2 at low to moderate intensities, but at higher intensities, greater variation in measurements occurs, likely due to tissue ischaemia or increased movement artefacts due to more frequent muscular contractions. THb has low variation during exercise, and does not appear to be a valid indicator of muscle oxygenation.

Overview

Integrity signals

Registry

Crossref · 10.1080/17461391.2017.1330899

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

6 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 16 references

Research works printed but not linked: 2

  1. Cornachione K., 2014, Science and Skiing VI, 369
  2. McCully K. K., 2000, Near‐infrared spectroscopy: What can it tell us about oxygen saturation in skeletal muscle, Exercise and Sport Sciences Reviews, 28, 123

Cited by

Metadata

Authors
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R.
Affiliations
  • Massey University (NZ)
  • The Hague University of Applied Sciences (NL)
Corresponding author
Crum, E. M.
Venue
European Journal of Sport Science
Publisher
Wiley
Published
2017-05-30
Volume
17
Issue
8
Pages
1037-1043
ISSN
  • 1536-7290 (ISSN-L)
  • 1746-1391
OpenAlex
W2618079828
Cited by
206
References
17
Citations by year
2026: 30 · 2025: 25 · 2024: 32 · 2023: 31 · 2022: 27 · 2021: 19 · 2020: 14 · 2019: 20 · 2018: 3 · 2017: 5
FWCI
17.03
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Sport Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
Massey University
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
muscle oxygen saturation, total hemoglobin, near-infrared spectroscopy, incremental cycling exercise, measurement reliability, whole-body oxygen consumption, heart rate, exercise intensity, muscle oxygenation
MeSH terms
Adolescent, Adult, Bicycling, Exercise Test, Female, Heart Rate, Hemoglobins, Humans, Male, Oximetry, Oxygen Consumption, Reproducibility of Results, Muscle, Skeletal, Spectroscopy, Near-Infrared, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.