Accuracy of human motion capture systems for sport applications; state‐of‐the‐art review
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Objective: Sport research often requires human motion capture of an athlete. It can, however, be labour‐intensive and difficult to select the right system, while manufacturers report on specifications which are determined in set‐ups that largely differ from sport research in terms of volume, environment and motion. The aim of this review is to assist researchers in the selection of a suitable motion capture system for their experimental set‐up for sport applications. An open online platform is initiated, to support (sport)researchers in the selection of a system and to enable them to contribute and update the overview. Design: systematic review; Method: Electronic searches in Scopus, Web of Science and Google Scholar were performed, and the reference lists of the screened articles were scrutinised to determine human motion capture systems used in academically published studies on sport analysis. Results: An overview of 17 human motion capture systems is provided, reporting the general specifications given by the manufacturer (weight and size of the sensors, maximum capture volume, environmental feasibilities), and calibration specifications as determined in peer‐reviewed studies. The accuracy of each system is plotted against the measurement range. Conclusion: The overview and chart can assist researchers in the selection of a suitable measurement system. To increase the robustness of the database and to keep up with technological developments, we encourage researchers to perform an accuracy test prior to their experiment and to add to the chart and the system overview (online, open access).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaramuzza, D., & Fraundorfer, F. (2011) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2011.943233 · Cited by 1,550
Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace
Dutta, T. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2011.09.011 · Cited by 435
The measurement of human motion: A comparison of commercially available systems
Richards, J. G. (1999) · Human Movement Science · doi:10.1016/s0167-9457(99)00023-8 · Cited by 434
Windolf, M., Götzen, N., & Morlock, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.024 · Cited by 415
Bonnechère, B., Jansen, B., Salvia, P., Bouzahouene, H., Omelina, L., Moiseev, F., Sholukha, V., Cornelis, J., Rooze, M., & Van Sint Jan, S. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.09.018 · Cited by 267
Duffield, R., Reid, M., Baker, J., & Spratford, W. (2010) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2009.07.003 · Cited by 257
Markerless Motion Capture through Visual Hull, Articulated ICP and Subject Specific Model Generation
Corazza, S., Mündermann, L., Gambaretto, E., Ferrigno, G., & Andriacchi, T. P. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0284-3 · Cited by 220
Accuracy of an optical active-marker system to track the relative motion of rigid bodies
Maletsky, L. P., Sun, J., & Morton, N. A. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.01.017 · Cited by 174
Concept and Application of LPM—A Novel 3-D Local Position Measurement System
Stelzer, A., Pourvoyeur, K., & Fischer, A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.838281 · Cited by 157
Accuracy of the LPM tracking system considering dynamic position changes
Ogris, G., Leser, R., Horsak, B., Kornfeind, P., Heller, M., & Baca, A. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.712712 · Cited by 113
Measurement of stride parameters using a wearable GPS and inertial measurement unit
Tan, H., Wilson, A. M., & Lowe, J. C. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.021 · Cited by 98
Markerless analysis of front crawl swimming
Ceseracciu, E., SAWACHA, Z., Fantozzi, S., Cortesi, M., Gatta, G., Corazza, S., & Cobelli, C. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.06.003 · Cited by 96
Dynamic accuracy of inertial measurement units during simple pendulum motion: Technical Note
Brodie, M. A., Walmsley, A., & Page, W. (2008) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840802125526 · Cited by 77
Sathyan, T., Shuttleworth, R., Hedley, M., & Davids, K. (2012) · Behavior Research Methods · doi:10.3758/s13428-012-0192-2 · Cited by 73
Rhodes, J., Mason, B. S., Perrat, B., Smith, M., & Goosey-Tolfrey, V. L. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.910608 · Cited by 68
Monnet, T., Samson, M., Bernard, A., David, L., & Lacouture, P. (2014) · Sports Engineering · doi:10.1007/s12283-014-0152-4 · Cited by 56
Klous, M., Müller, E. A., & Schwameder, H. (2010) · Journal of Sports Sciences · doi:10.1080/02640414.2010.507253 · Cited by 50
The accuracy of the Microsoft Kinect in joint angle measurement
Choppin, S. B., Lane, B., & Wheat, J. S. (2014) · Sports Technology · doi:10.1080/19346182.2014.968165 · Cited by 37
A novel approach for tracking high speed skaters in sports using a panning camera
Liu, G., Tang, X., Cheng, H.-D., Huang, J., & Liu, J. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2009.03.022 · Cited by 33
Stochastic magnetic measurement model for relative position and orientation estimation
Schepers, H. M., & Veltink, P. H. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/6/065801 · Cited by 20
Cited by
Motion Capture Technology in Industrial Applications: A Systematic Review
Menolotto, M., Komaris, D.-S., Tedesco, S., O’Flynn, B., & Walsh, M. (2020) · Sensors · doi:10.3390/s20195687 · Cited by 306
Exploring the Role of Wearable Technology in Sport Kinematics and Kinetics: A Systematic Review
Adesida, Y., Papi, E., & McGregor, A. H. (2019) · Sensors · doi:10.3390/s19071597 · Cited by 288
A comparison of currently available optoelectronic motion capture systems
Topley, M., & Richards, J. G. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109820 · Cited by 196
Motion Capture Technologies for Ergonomics: A Systematic Literature Review
Salisu, S., Ruhaiyem, N. I. R., Eisa, T. A. E., Nasser, M., Saeed, F., & Younis, H. A. (2023) · Diagnostics · doi:10.3390/diagnostics13152593 · Cited by 58
Althouse, D., Weeks, C., Spencer, S. B., Park, J., Thompson, B. J., & Louder, T. (2025) · Signals · doi:10.3390/signals6010011 · Cited by 3
“Numerous devices are available for measuring CMJ performance, with force platform dynamometry and optical motion capture regarded as criterion tools in laboratory settings [8–10].”
Metadata
- Authors
- van der Kruk, E., & Reijne, M. M.
- Venue
- European Journal of Sport Science
- Publisher
- Wiley
- Published
- 2018-05-09
- Volume
- 18
- Issue
- 6
- Pages
- 806-819
- ISSN
- 1536-7290 (ISSN-L)
- 1746-1391
- OpenAlex
- W2803023819
- Cited by
- 522
- References
- 20
- FWCI
- 15.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.