CFD modelling of naturally ventilated double-skin facades with Venetian blinds
Open accessThe DOI matches its Crossref record; 10 of the 11 references it cites were found in a registry or an index.
Abstract
This study describes computational fluid dynamics (CFD) modelling of naturally ventilated double-skin facades (DSFs) with Venetian blinds inside the facade cavity. The 2D modelling work investigates the coupled convective, conductive and radiative heat transfer through the DSF system. The angles of the Venetian blind can be adjusted and a series of angles (0°, 30°, 45°, 60° and 80°) have been modelled. The modelling results are compared with the measurements from a section of a prototype-facade testing facility and with predictions from a component-based nodal model. Agreement between the three methods is generally good. It is thought that discrepancies in the results are caused by the simplification of the CFD model resulting in less turbulence mixing within the facade cavity. The CFD simulation output suggests that the presence of the Venetian blinds is able to enhance the natural ventilation flow within the facade cavity and significantly reduce the heat gains to the internal environment. It was also found that the convective heat transfer coefficients on the glazing surfaces are insensitive to the blind angles. The work demonstrated the capability of CFD for modelling complicated heat transfer processes through the DSF system and offered some guidance for CFD practitioners who wish to model similar type of flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Computational Fluid Dynamics: The Finite Volume Method
Versteeg, H. K., & Malalasekera, W. M. G. (1995) · Cited by 4,636
Multiscale model for turbulent flows
Wilcox, D. C. (1988) · AIAA Journal · doi:10.2514/3.10042 · Cited by 377 · cited 1×
“In this work, the k-omega model (Wilcox 1986 ) was used.”
MethodNatural ventilation performance of a double-skin façade with a solar chimney
Ding, W., Hasemi, Y., & Yamada, T. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2004.08.002 · Cited by 211 · cited 1×
“Smaller scale DSF experiments by Ding et al. (2005) also demonstrated the energy saving potential of using DSFs.”
BackgroundSafer, N., Woloszyn, M., & Roux, J. J. (2005) · Solar Energy · doi:10.1016/j.solener.2004.09.016 · Cited by 169 · cited 2×
“( 2005 ) in which the Venetian blinds were treated as porous media and the glazing elements as semi-transparent surfaces in order to reduce the mesh size.”
BackgroundMethodZollner, A., Winter, E. R. F., & Viskanta, R. (2002) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(02)00160-6 · Cited by 100 · cited 2×
“Zollner et al. (2002) conducted parametric studies of DSFs by varying the cavity depth in a full scale experiment.”
BackgroundMethodEnergy performance assessment of a window with a horizontal Venetian blind
Shahid, H. U., & Naylor, D. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2004.11.008 · Cited by 81 · cited 2×
“For cases where the blinds are very close to the glazing layers, the CHTCs can be enhanced (Shahid and Naylor 2005).”
BackgroundXu, L., & OJIMA, T. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.07.026 · Cited by 64 · cited 1×
“…of DSFs. Previous investigations using field measurements on a two-storey residential house have shown that the use of a DSF may lead to a reduction in energy usage in summer of up to 15% by using natural ventilation and up to 30% in winter by using passive solar heating (Xu and Ojima 2007).”
MethodEVALUATION OF AN APPROXIMATE METHOD FOR PREDICTING THEUVALUE OF A WINDOW WITH A BETWEEN-PANES BLIND
Naylor, D., & Collins, M. (2005) · Numerical Heat Transfer Part A Applications · doi:10.1080/10407780590889158 · Cited by 25 · cited 2×
“Shahid and Naylor 2005 , Naylor and Collins 2005 ).”
BackgroundCFD modelling of convective heat transfer from a window with adjacent venetian blinds
Marjanovic-Halburd, L., Cook, M., Hanby, V. I., & Rees, S. (2005) · DMU Open Research Archive (De Montfort University) · Cited by 7
Self-citationExperimental study of airflow and heat transfer in a double skin facade with blinds
Infield, D. G. (2007) · Cited by 1
Self-citation
Research works printed but not linked: 3
- Nodal network and CFD simulation of airflow and heat transfer in double skin facades with blinds, Paper 23. V I Hanby, Proceedings of System Simulation in Buildings 06. System Simulation in Buildings 06Liege, Belgium2006University of Liege
- An evaluation of turbulence models for modelling natural convection in cavities. Y Ji, M J Cook, Journal of Engineering Applications of Computational Fluid Mechanics. in press
- Development of simplified tools for evaluation energy performance of double fac¸ades. D Paassen, M V D Voorden, The international building physics conference. Eindhoven2000. September
Cited by
Exploring the advantages and challenges of double-skin façades (DSFs)
Ghaffarianhoseini, A., Ghaffarianhoseini, A., Berardi, U., Tookey, J., Li, D. H. W., & Kariminia, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.130 · Cited by 231
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
A comprehensive review of solar facades. Transparent and translucent solar facades
Quesada, G., Rousse, D., Dutil, Y., Badache, M., & Hallé, S. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.059 · Cited by 158
“[51] described computational fluid dynamics modeling of naturally ventilated double-skin facades (DSF) with Venetian blinds inside the facade cavity.”
BackgroundPomponi, F., Piroozfar, P. A. E., Southall, R., Ashton, P., & Farr, E. R. P. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.075 · Cited by 181
Impact of double skin facade constructional features on heat transfer and fluid dynamic behaviour
Jankovic, A., & Goia, F. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107796 · Cited by 89
Preet, S., Mathur, J., & Mathur, S. (2022) · Solar Energy · doi:10.1016/j.solener.2022.02.055 · Cited by 83
Naturally ventilated double-skin façade with adjustable louvers
Tao, Y., Fang, X. Z., Setunge, S., Tu, J. Y., Liu, J., & Shi, L. X. (2021) · Solar Energy · doi:10.1016/j.solener.2021.07.013 · Cited by 57
On the turbulence models and turbulent Schmidt number in simulating stratified flows
Shi, Z., Chen, J., & Chen, Q. (2015) · Journal of Building Performance Simulation · doi:10.1080/19401493.2015.1004109 · Cited by 47
“Ji et al. (2008) adopted the k − ω model (Wilcox 1988) to investigate naturally ventilated double-skin facades with Venetian blinds inside the facade cavity.”
MethodOn the use of tensegrity structures for kinetic solar facades of smart buildings
Fraternali, F., Chiara, E. D., & Skelton, R. E. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/10/105032 · Cited by 47
Controlling naturally ventilated double-skin façade to reduce energy consumption in buildings
Zhao, X., Wei, A., Zou, S., Dong, Q., Qi, J., Song, Y., & Shi, L. X. (2024) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2024.114649 · Cited by 46
A CFD-Based Parametric Thermal Performance Analysis of Supply Air Ventilated Windows
Khosravi, S. N., & Mahdavi, A. (2021) · Energies · doi:10.3390/en14092420 · Cited by 28
“[27] DSF (OAC) 2D/S/DC A numerical method was employed to evaluate the thermal behavior of the ventilated faced with different angles of the venetian blind.”
BackgroundMethodInfluentialPomponi, F., Barbosa, S. A., & Piroozfar, P. A. E. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.03.215 · Cited by 29
“Existing literatures on DSF cover a broad range of different aspects, such as shading elements in the cavity [6-9], airflow analysis and prediction [10-13], fire and smoke spreading issues [14-17], operational and embodied energy [18, 19] and natural ventilation [5, 20-22].”
BackgroundDetermining the potential risks of naturally ventilated double skin façades
Dong, Q., Zhao, X., Song, Y., Qi, J., & Shi, L. X. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.114064 · Cited by 30
Bovo, M., Santolini, E., Barbaresi, A., Tassinari, P., & Torreggiani, D. (2022) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2021.106652 · Cited by 24
Tao, Y., Yan, Y., Fang, X. Z., Zhang, H., Tu, J. Y., & Shi, L. X. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109002 · Cited by 25
Matour, S., Garcia-Hansen, V., Omrani, S., Hassanli, S., & Drogemuller, R. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105323 · Cited by 26
Janković, A., & Goia, F. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112024 · Cited by 15
Huang, Y., Yeboah, S. K., & Shao, J. (2022) · Building Services Engineering Research and Technology · doi:10.1177/01436244221129763 · Cited by 12
“Ji et al.(18) found that 80° Venetian blind angle opening performs well and increases natural ventilation by up to 35%.”
BackgroundZhao, X., Song, Y., Huang, L., Song, Z., Dong, Q., Qi, J., & Shi, L. X. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.124560 · Cited by 15
International Energy Agency EBC Annex 80 - Resilient Cooling of Buildings - State of the Art Review
Zhengtao, A., Akander, J., Arens, E. A., Arghand, T., Attia, S., Bogatu, D., Bozonnet, E., Breesch, H., Cehlin, M., Chiesa, G., et al. (2022) · doi:10.52776/coxk4763 · Cited by 28
Kalua, A., & Jones, J. B. (2020) · Philosophies · doi:10.3390/philosophies5040030 · Cited by 9
Alkhatib, H., O’Neill, N., & Norton, B. (2025) · Energy Reports · doi:10.1016/j.egyr.2025.09.038 · Cited by 10
Hosseini, I. M., Saradj, F. M., Maddahi, S. M., & Ghobadian, V. (2020) · International journal of energy and environmental engineering · doi:10.1007/s40095-020-00338-0 · Cited by 9
“The application of the glass façade has been of great interest to architects in recent years [11, 12].”
BackgroundIyi, D., Hasan, R., & Penlington, R. (2013) · Procedia Engineering · doi:10.1016/j.proeng.2013.03.157 · Cited by 6
Belpoliti, V., Mushtaha, E. S. N., Abdeen, A., & Elmualim, A. A. (2024) · Journal of Architectural Engineering · doi:10.1061/jaeied.aeeng-1682 · Cited by 5
CFD Modelling of Naturally Ventilated Double Skin Façades: Comparisons among 2D and 3D Models
Lops, C., Germano, N., Matera, S., D’Alessandro, V., & Montelpare, S. (2021) · TECNICA ITALIANA-Italian Journal of Engineering Science · doi:10.18280/ti-ijes.652-429 · Cited by 5
“Only in the late 1970s, investigations started to be carried on to measure and predict these systems' effectiveness [1].”
BackgroundAn Appraisal of Double Skin Facade in Building Design: Architectural Intervention and Sustainability
Nasir, O., & Kamal, M. A. (2023) · International Journal of Architecture and Urbanism · doi:10.32734/ijau.v7i1.11760 · Cited by 8
“Venetian blinds installed inside the air cavity have also been recommended that would promote ventilation and airflow [51].”
BackgroundSolar radiation-controllable double-skin façades to enhance natural ventilation for green buildings
Zhao, X., Song, Y., Dong, Q., Huang, L., Wang, Y., & Shi, L. X. (2025) · Renewable Energy · doi:10.1016/j.renene.2025.123805 · Cited by 3
Naturally Ventilated Double Skin Façades: Comparisons Between Different CFD Models
Lops, C., Germano, N., Ricciutelli, A., D’Alessandro, V., & Montelpare, S. (2021) · Mathematical Modelling and Engineering Problems · doi:10.18280/mmep.080601 · Cited by 2
Application of physical theory of cavity in the construction of double skin facades
Bielek, B., Szabo, D. R., Klem, J., & Kaniková, K. (2021) · Curved and Layered Structures · doi:10.1515/cls-2022-0004 · Cited by 3
Plaster ventilated façade system for renovating modern and ancient buildings. A CFD analysis
Corrao, R., & Placa, E. L. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/863/1/012046 · Cited by 2
“This method, adopted by several authors, let to focus the analysis on a significative section whose behaviour is analogous to the other ones [12, 13, 14].”
MethodHendrik, M. L., & Rahmayanti, R. (2023) · JAMBURA Journal of Architecture · doi:10.37905/jjoa.v5i1.19709 · Cited by 1
Analiza techniczna SWOT systemu podwójnej fasady budynku
Prokopowicz, Z., & Jadwiszczak, P. (2026) · GAZ WODA I TECHNIKA SANITARNA · doi:10.65545/gwits.2026.05.06 · Cited by 1
ATINER's Conference Paper Series CON2012-0248
Roelofs, B., Varrasso, A., & McCaffrey, C. (2012)
Framework for Integrated Multi-Scale CFD Simulations in Architectural Design
Kalua, A. (2021) · VTechWorks (Virginia Tech)
Matour, S. (2022) · Queensland University of Technology · doi:10.5204/thesis.eprints.231909 · Cited by 1
FLORISM: FUSING BIOMIMETIC ARCHITECTURE WITH DIVERSE FLOWER STRUCTURES
Fonseka, E. A. G., & Romanov, O. (2024) · Bulletin of Belgorod State Technological University named after V G Shukhov · doi:10.34031/2071-7318-2024-10-3-68-81
Metadata
- Authors
- Ji, Y., Cook, M. J., Hanby, V., Infield, D. G., Loveday, D. L., & Mei, L.
- Affiliations
- De Montfort University (GB)
- Loughborough University (GB)
- Corresponding author
- Ji, Y.
- Venue
- Journal of Building Performance Simulation
- Publisher
- Informa UK Limited
- Published
- 2008-09
- Volume
- 1
- Issue
- 3
- Pages
- 185-196
- ISSN
- 1940-1493 (ISSN-L)
- 1940-1507
- OpenAlex
- W2062037213
- Cited by
- 37
- References
- 11
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 8 · 2021: 9 · 2020: 2 · 2017: 1 · 2016: 1 · 2015: 3 · 2013: 1 · 2012: 2
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- green
- usir.salford.ac.uk
- Licence
- cc-by
- Locations
- Journal of Building Performance Simulation (publishedVersion)
- University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
- DMU Open Research Archive (De Montfort University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
- Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- double-skin facade, natural ventilation, venetian blinds, convective heat transfer, radiative transfer, heat gain reduction, convective heat transfer coefficient
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.