CoChat

CFD modelling of naturally ventilated double-skin facades with Venetian blinds

Open access
Ji, Y., Cook, M. J., Hanby, V., Infield, D. G., Loveday, D. L., Mei, L. · 2008 · Journal of Building Performance Simulation

The DOI matches its Crossref record; 10 of the 11 references it cites were found in a registry or an index.

Abstract

This study describes computational fluid dynamics (CFD) modelling of naturally ventilated double-skin facades (DSFs) with Venetian blinds inside the facade cavity. The 2D modelling work investigates the coupled convective, conductive and radiative heat transfer through the DSF system. The angles of the Venetian blind can be adjusted and a series of angles (0°, 30°, 45°, 60° and 80°) have been modelled. The modelling results are compared with the measurements from a section of a prototype-facade testing facility and with predictions from a component-based nodal model. Agreement between the three methods is generally good. It is thought that discrepancies in the results are caused by the simplification of the CFD model resulting in less turbulence mixing within the facade cavity. The CFD simulation output suggests that the presence of the Venetian blinds is able to enhance the natural ventilation flow within the facade cavity and significantly reduce the heat gains to the internal environment. It was also found that the convective heat transfer coefficients on the glazing surfaces are insensitive to the blind angles. The work demonstrated the capability of CFD for modelling complicated heat transfer processes through the DSF system and offered some guidance for CFD practitioners who wish to model similar type of flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/19401490802478303

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Research works printed but not linked: 3

  1. Nodal network and CFD simulation of airflow and heat transfer in double skin facades with blinds, Paper 23. V I Hanby, Proceedings of System Simulation in Buildings 06. System Simulation in Buildings 06Liege, Belgium2006University of Liege
  2. An evaluation of turbulence models for modelling natural convection in cavities. Y Ji, M J Cook, Journal of Engineering Applications of Computational Fluid Mechanics. in press
  3. Development of simplified tools for evaluation energy performance of double fac¸ades. D Paassen, M V D Voorden, The international building physics conference. Eindhoven2000. September

Cited by

See all 37

Metadata

Authors
Ji, Y., Cook, M. J., Hanby, V., Infield, D. G., Loveday, D. L., & Mei, L.
Affiliations
  • De Montfort University (GB)
  • Loughborough University (GB)
Corresponding author
Ji, Y.
Venue
Journal of Building Performance Simulation
Published
2008-09
Volume
1
Issue
3
Pages
185-196
ISSN
  • 1940-1493 (ISSN-L)
  • 1940-1507
OpenAlex
W2062037213
Cited by
37
References
11
Citations by year
2026: 1 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 8 · 2021: 9 · 2020: 2 · 2017: 1 · 2016: 1 · 2015: 3 · 2013: 1 · 2012: 2
FWCI
0.00
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Journal of Building Performance Simulation (publishedVersion)
  • University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
  • DMU Open Research Archive (De Montfort University) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
  • Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
double-skin facade, natural ventilation, venetian blinds, convective heat transfer, radiative transfer, heat gain reduction, convective heat transfer coefficient

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.