CoChat

Establishing in vitro in vivo correlations to screen monoclonal antibodies for physicochemical properties related to favorable human pharmacokinetics

Open access
Avery, Lindsay B., Wade, Jason, Wang, Mengmeng, Tam, Amy, King, Amy, Piche-Nicholas, Nicole, Kavosi, Mania S., Penn, Steve, Cirelli, David, Kurz, Jeffrey C., Zhang, Minlei, Cunningham, Orla, Jones, Rhys, Fennell, Brian J., McDonnell, Barry, Sakorafas, Paul, Apgar, James, Finlay, William J., Lin, Laura, Bloom, Laird, O'Hara, Denise M. · 2018 · mAbs
Cited by 99

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Implementation of in vitro assays that correlate with in vivo human pharmacokinetics (PK) would provide desirable preclinical tools for the early selection of therapeutic monoclonal antibody (mAb) candidates with minimal non-target-related PK risk. Use of these tools minimizes the likelihood that mAbs with unfavorable PK would be advanced into costly preclinical and clinical development. In total, 42 mAbs varying in isotype and soluble versus membrane targets were tested in in vitro and in vivo studies. MAb physicochemical properties were assessed by measuring non-specific interactions (DNA- and insulin-binding ELISA), self-association (affinity-capture self-interaction nanoparticle spectroscopy) and binding to matrix-immobilized human FcRn (surface plasmon resonance and column chromatography). The range of scores obtained from each in vitro assay trended well with in vivo clearance (CL) using both human FcRn transgenic (Tg32) mouse allometrically projected human CL and observed human CL, where mAbs with high in vitro scores resulted in rapid CL in vivo. Establishing a threshold value for mAb CL in human of 0.32 mL/hr/kg enabled refinement of thresholds for each in vitro assay parameter, and using a combinatorial triage approach enabled the successful differentiation of mAbs at high risk for rapid CL (unfavorable PK) from those with low risk (favorable PK), which allowed mAbs requiring further characterization to be identified. Correlating in vitro parameters with in vivo human CL resulted in a set of in vitro tools for use in early testing that would enable selection of mAbs with the greatest likelihood of success in the clinic, allowing costly late-stage failures related to an inadequate exposure profile, toxicity or lack of efficacy to be avoided.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/19420862.2017.1417718

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 99

Metadata

Authors
Avery, L. B., Wade, J., Wang, M., Tam, A., King, A., Piche-Nicholas, N., Kavosi, M. S., Penn, S., Cirelli, D., Kurz, J. C., Zhang, M., Cunningham, O., Jones, R., Fennell, B. J., McDonnell, B., Sakorafas, P., Apgar, J., Finlay, W. J., Lin, L., Bloom, L., & O'Hara, D. M.
Venue
mAbs
Published
2018-01-29
Volume
10
Issue
2
Pages
244-255
ISSN
  • 1942-0862 (ISSN-L)
  • 1942-0870
OpenAlex
W2776027284
Cited by
99
References
17
FWCI
4.73
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Establishing in vitro in vivo correlations to screen monoclonal antibodies for physicochemical properties related to favorable human pharmacokinetics. https://app.cochat.ai/papers/10.1080/19420862.2017.1417718
The paper
Avery, L. B., Wade, J., Wang, M., Tam, A., King, A., Piche-Nicholas, N., Kavosi, M. S., Penn, S., Cirelli, D., Kurz, J. C., Zhang, M., Cunningham, O., Jones, R., Fennell, B. J., McDonnell, B., Sakorafas, P., Apgar, J., Finlay, W. J., Lin, L., . . . O'Hara, D. M. (2018). Establishing in vitro in vivo correlations to screen monoclonal antibodies for physicochemical properties related to favorable human pharmacokinetics. mAbs. https://doi.org/10.1080/19420862.2017.1417718

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.