The Inactivation of Enzymes by Ultrasound—A Review of Potential Mechanisms
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The application of ultrasonic energy can inactivate many enzymes. The ultrasound shock waves produce cavitation and acoustic streaming in the liquid medium, which generates adequate mechanical, thermal, and chemical effects to inactivate enzymes. The extremely fast cycles of pressurization and depressurization and the resultant (localized) high temperature lead to rapid formation and collapse of bubbles. The rapid formation and collapse of bubbles is capable of breaking the hydrogen bonds as well as the van der Waals interactions in polypeptide chains. The application of ultrasound alters the secondary and tertiary structure of enzymes and leads to the loss in their biological activity. In this article, the authors review the recent advances made in the inactivation of common enzymes by the application of ultrasound alone or in combination with heat and pressure. The associated inactivation mechanisms and the factors affecting the enzyme inactivation are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications and opportunities for ultrasound assisted extraction in the food industry — A review
Vilkhu, K., Mawson, R., Simons, L., & Bates, D. (2008) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2007.04.014 · Cited by 1,394
Inactivation of microbes using ultrasound: a review
Piyasena, P., Mohareb, E., & McKellar, R. C. (2003) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(03)00075-8 · Cited by 886
Opportunities and Challenges in Application of Ultrasound in Food Processing
Rastogi, N. K. (2011) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408391003770583 · Cited by 249
Cited by
Rahman, M. M., & Lamsal, B. P. (2021) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12709 · Cited by 438
Bioavailability of Glucosinolates and Their Breakdown Products: Impact of Processing
Barba, F. J., Nikmaram, N., Roohinejad, S., Khelfa, A., Zhu, Z., & Koubaa, M. (2016) · Frontiers in Nutrition · doi:10.3389/fnut.2016.00024 · Cited by 336
Application of ultrasound technology in processing of ready-to-eat fresh food: A review
Chen, F., Zhang, M., & Yang, C.-H. (2020) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2019.104953 · Cited by 284
Self-citationRecent Advances of Polyphenol Oxidases in Plants
Zhang, S. (2023) · Molecules · doi:10.3390/molecules28052158 · Cited by 240
“High pressure treatment in water with little damage to the raw material [87] has been used in fruits such as blueberries [17] and avocados [88].”
BackgroundApplication of ultrasonic technology in postharvested fruits and vegetables storage: A review
Jiang, Q., Zhang, M., & Xu, B. (2020) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2020.105261 · Cited by 204
Self-citation
Metadata
- Authors
- Islam, M. N., Zhang, M., & Adhikari, B.
- Venue
- Food Reviews International
- Publisher
- Informa UK Limited
- Published
- 2013-12-16
- Volume
- 30
- Issue
- 1
- Pages
- 1-21
- ISSN
- 1525-6103 (ISSN-L)
- 8755-9129
- OpenAlex
- W2067523152
- Cited by
- 191
- References
- 3
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.