Magnetic resonance imaging in 300 cases of placenta accreta: surgical correlation of new findings
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To establish the usefulness of placental magnetic resonance in patients with a diagnosis of placenta accreta through the correlation of diagnostic images and surgical findings. METHODS: Three hundred patients with ultrasound signs of placenta accreta were studied. In 252 patients, magnetic resonance imaging (MRI) was performed in a closed 1.5 T-resonator, and in 48 patients, open 0.23 T-set was used. T1 and T2 slices in the three planes were performed, and placental invasion was classified in depth levels and topographic areas in relation to the posterior vesical wall. The final degree of invasion was established during surgery according to clinical and anatomical criteria. The information obtained with MRI was analyzed, thus establishing its relevance to the change in surgical technique. RESULTS: In 286 cases, MRI provided topographic information of placental invasion, and in 90 patients, it modified invasion levels. Undiagnosed parametrium extent was determined in 11 cases, and 11 other cases were reclassified as placenta previa. Changes in conduct following MRI study included: recommendation to modify surgery date at week 35, recommendation for prophylactic ureteral catheterization, recommendation for the use of intraoperative blood salvage, possibility of approach through Pfannenstiel incision, probability of segmental myometrial approach, probability of aortic clamping, need to investigate subclinical disseminated intravascular coagulation, need of posterior pelvic dissection, and the possibility of uterine conservation. CONCLUSIONS: Magnetic resonance imaging turned out to be essential to define the topography and area of placental invasion. New findings modified surgical tactic and technique, allowing a reduction in historical morbidity and a significant increase in conservative surgeries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical risk factors for placenta previa–placenta accreta
Miller, D. A., Chollet, J. A., & Goodwin, T. M. (1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70463-0 · Cited by 1,106
The management of placenta percreta: Conservative and operative strategies
O'Brien, J. M., Barton, J. R., & Donaldson, E. S. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70117-5 · Cited by 625
Finberg, H. J., & Williams, J. W. (1992) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1992.11.7.333 · Cited by 456
Placenta Accreta—Summary of 10 Years: A Survey of 310 Cases
Gielchinsky, Y., Rojansky, N., Fasouliotis, S. J., & Ezra, Y. (2002) · Placenta · doi:10.1053/plac.2001.0764 · Cited by 376
Placenta accreta: evaluation with color Doppler US, power Doppler US, and MR imaging.
Levine, D., Hulka, C. A., Ludmir, J., Li, W., & Edelman, R. R. (1997) · Radiology · doi:10.1148/radiology.205.3.9393534 · Cited by 355
Anterior placenta percreta: surgical approach, hemostasis and uterine repair
Jaraquemada, J. M. P., Pesaresi, M., Nassif, J. C., & Hermosid, S. (2004) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1080/j.0001-6349.2004.00517.x · Cited by 229
Self-citationMRI appearance of placenta percreta and placenta accreta
Maldjian, C., Adam, R., Pelosi, M., Pelosi, M., Rudelli, R. D., & Maldjian, J. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00035-1 · Cited by 170
Characterization of placenta accreta using transvaginal sonography and color Doppler imaging
Lerner, J. P., Deane, S., & Timor‐Tritsch, I. E. (1995) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1995.05030198.x · Cited by 148
Color flow mapping for myometrial invasion in women with a prior cesarean delivery
Twickler, D. M., Lucas, M. J., Balis, A. B., Santos-Ramos, R., Martin, L., Malone, S., & Rogers, B. (2000) · The Journal of Maternal-Fetal Medicine · doi:10.1002/1520-6661(200011/12)9:6<330::aid-mfm1002>3.0.co;2-o · Cited by 147
Antepartum diagnosis of placenta previa percreta by magnetic resonance imaging.
Thorp, J. M., Councell, R. B., Sandridge, D. A., & Wiest, H. H. (1992) · PubMed · Cited by 113
Irving, F. C., & Hertig, A. T. (1937) · Cited by 93
Placenta accreta. Additional sonographic observations
Hoffman-Tretin, J. C., Koenigsberg, M., Rabin, A., & Anyaegbunam, A. (1992) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1992.11.1.29 · Cited by 88
PREGNANCY AND THE SAFETY OF MAGNETIC RESONANCE IMAGING
Kanal, E. (1994) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00346-9 · Cited by 80
PELOSI, M. (1999) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(98)00426-8 · Cited by 71
Kirkinen, P. P., Helin, H. ‐., Vanninen, R. L., & Partanen, K. P. L. (1998) · Journal of Clinical Ultrasound · doi:10.1002/(sici)1097-0096(199802)26:2<90::aid-jcu7>3.0.co;2-d · Cited by 61
First-trimester diagnosis of placenta previa percreta by magnetic resonance imaging
Thorp, J. M., Wells, S. R., Wiest, H. H., Jeffries, L., & Lyles, E. (1998) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(98)70451-x · Cited by 43
Pelvic Varices Mimnicking Placenta Percreta at Sonography
Russ, P. D., Tomaszewski, G. M., & Coffin, C. T. (2000) · Journal of diagnostic medical sonography · doi:10.1177/875647930001600501 · Cited by 3
Cited by
Placenta Previa, Placenta Accreta, and Vasa Previa
Oyelese, Y., & Smulian, J. C. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000207559.15715.98 · Cited by 975
Accuracy of Ultrasonography and Magnetic Resonance Imaging in the Diagnosis of Placenta Accreta
Warshak, C. R., Eskander, R., Hull, A. D., Scioscia, A. L., Mattrey, R. F., Benirschke, K., & Resnik, R. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000233155.62906.6d · Cited by 515
Placenta Accreta: Spectrum of US and MR Imaging Findings
Baughman, W. C., Corteville, J. E., & Shah, R. R. (2008) · RadioGraphics · doi:10.1148/rg.287085060 · Cited by 341
Conservative Management of Abnormally Invasive Placentation
Timmermans, S., van Hof, A. C., & Duvekot, J. J. (2007) · Obstetrical & Gynecological Survey · doi:10.1097/01.ogx.0000271133.27011.05 · Cited by 270
Placenta Accreta, Increta, and Percreta
Wortman, A. C., & Alexander, J. M. (2013) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/j.ogc.2012.12.002 · Cited by 245
Metadata
- Authors
- Jaraquemada, J. M. P., & Bruno, C. H.
- Venue
- Acta Obstetricia et Gynecologica Scandinavica
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 84
- Issue
- 8
- Pages
- 716-724
- ISSN
- 0001-6349 (ISSN-L)
- 1600-0412
- OpenAlex
- W2113199806
- Cited by
- 185
- References
- 17
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.