The DOI matches its Crossref record.
Correlation between Charge Movement and Ionic Current during Slow Inactivation in Shaker K+ Channels
Open accessAbstract
Prolonged depolarization induces a slow inactivation process in some K+ channels. We have studied ionic and gating currents during long depolarizations in the mutant Shaker H4-Δ(6–46) K+ channel and in the nonconducting mutant (Shaker H4-Δ(6–46)-W434F). These channels lack the amino terminus that confers the fast (N-type) inactivation (Hoshi, T., W.N. Zagotta, and R.W. Aldrich. 1991. Neuron. 7:547–556). Channels were expressed in oocytes and currents were measured with the cut-open-oocyte and patch-clamp techniques. In both clones, the curves describing the voltage dependence of the charge movement were shifted toward more negative potentials when the holding potential was maintained at depolarized potentials. The evidences that this new voltage dependence of the charge movement in the depolarized condition is associated with the process of slow inactivation are the following: (a) the installation of both the slow inactivation of the ionic current and the inactivation of the charge in response to a sustained 1-min depolarization to 0 mV followed the same time course; and (b) the recovery from inactivation of both ionic and gating currents (induced by repolarizations to −90 mV after a 1-min inactivating pulse at 0 mV) also followed a similar time course. Although prolonged depolarizations induce inactivation of the majority of the channels, a small fraction remains non–slow inactivated. The voltage dependence of this fraction of channels remained unaltered, suggesting that their activation pathway was unmodified by prolonged depolarization. The data could be fitted to a sequential model for Shaker K+ channels (Bezanilla, F., E. Perozo, and E. Stefani. 1994. Biophys. J. 66:1011–1021), with the addition of a series of parallel nonconducting (inactivated) states that become populated during prolonged depolarization. The data suggest that prolonged depolarization modifies the conformation of the voltage sensor and that this change can be associated with the process of slow inactivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Voltage Sensor in Voltage-Dependent Ion Channels
Bezanilla, F. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.555 · Cited by 884
Self-citationThe moving parts of voltage-gated ion channels
YELLEN, G. (1998) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583598003448 · Cited by 478
Structural mechanism of C-type inactivation in K+ channels
Cuello, L. G., Jogini, V., Cortes, D. M., & Perozo, E. (2010) · Nature · doi:10.1038/nature09153 · Cited by 477
A proton pore in a potassium channel voltage sensor reveals a focused electric field
Starace, D. M., & Bezanilla, F. (2004) · Nature · doi:10.1038/nature02270 · Cited by 398
Self-citationLeMasurier, M., Heginbotham, L., & Miller, C. (2001) · The Journal of General Physiology · doi:10.1085/jgp.118.3.303 · Cited by 345
Metadata
- Authors
- Olcese, R., Latorre, R., Toro, L., Bezanilla, F., & Stefani, E.
- Venue
- The Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 1997-11-01
- Volume
- 110
- Issue
- 5
- Pages
- 579-589
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2054121895
- Cited by
- 184
- References
- 0
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation between Charge Movement and Ionic Current during Slow Inactivation in Shaker K+ Channels. https://app.cochat.ai/papers/10.1085/jgp.110.5.579
- The paper
- Olcese, R., Latorre, R., Toro, L., Bezanilla, F., & Stefani, E. (1997). Correlation between Charge Movement and Ionic Current during Slow Inactivation in Shaker K+ Channels. The Journal of General Physiology. https://doi.org/10.1085/jgp.110.5.579
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.